• Title/Summary/Keyword: loading protocol

Search Result 100, Processing Time 0.029 seconds

Immediately loaded dental implants with fixed prostheses using a computer-guided surgery in a mental retardation patient: a case report (정신지체장애환자에서 Computer-Guided Surgery를 이용한 임플란트 식립 및 즉시 보철물 장착: 증례보고)

  • Han, Se-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.246-252
    • /
    • 2014
  • $Br{\aa}nemark^{\prime}s$ original protocol required 4 to 6 months for implant osseointegration before placement of the definitive prosthesis. Although this approach gave very predictable results, it had certain drawbacks. The main disadvantages of this approach were prolonged treatment time, two surgical procedures, placement of a removable prosthesis that required modifications during the course of treatment, and a greater number of appointments. Immediate implant loading is a viable treatment method for selected cases. One of the greatest advantages of this method is the virtual surgery, which precedes the actual clinical treatment and eliminates any need for last minute decisions. The actual surgery time is decreased, since all steps are predetermined. These advantages aren't only more useful for normal patients but also for the mental retardation patients whose cooperation is difficult. This article presents a clinical approach made possible due to the guided implant surgery and CAD/CAM technique.

Biomechanical Analysis of a Combined Interspinous Spacer with a Posterior Lumbar Fusion with Pedicle Screws (척추경나사못을 이용한 유합술과 동반 시술된 극돌기간 삽입기구의 생체역학적 연구)

  • Kim, Y.H.;Park, E.Y.;Lee, S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.276-282
    • /
    • 2015
  • Recently, during the multi-level fusion with pedicle screws, interspinous spacer are sometimes substituted for the most superior level of the fusion in an attempt to reduce the number of fusion level and likelihood of degeneration process at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the interspinous spacer combined with posterior lumbar fusion with a previously-validated 3-dimensional FE model of the intact lumbar spine (L1-S1). The post-operative models were made by modifying the intact model to simulate the implantation of interspinous spacer and pedicle screws at the L3-4 and L4-5. Four different configurations of the post-op model were considered: (1) a normal spinal model; (2) Type 1, one-level fusion using posterior pedicle screws at the L4-5; (3) Type 2, two-level (L3-5) fusion; (4) Type 3, Type 1 plus Coflex$^{TM}$ at the L3-4. hybrid protocol (intact: 10 Nm) with a compressive follower load of 400N were used to flex, extend, axially rotate and laterally bend the FE model. As compared to the intact model, Type 2 showed the greatest increase in Range of motion (ROM) at the adjacent level (L2-3), followed Type 3, and Type 1 depending on the loading type. At L3-4, ROM of Type 2 was reduced by 34~56% regardless of loading mode, as compared to decrease of 55% in Type 3 only in extension. In case of normal bone strength model (Type 3_Normal), PVMS at the process and the pedicle remained less than 20% of their yield strengths regardless of loading, except in extension (about 35%). However, for the osteoporotic model (Type 3_Osteoporotic), it reached up to 56% in extension indicating increased susceptibility to fracture. This study suggested that substitution of the superior level fusion with the interspinous spacer in multi-level fusion may be able to offer similar biomechanical outcome and stability while reducing likelihood of adjacent level degeneration.

Statistical Estimation of the Number of Contending Stations and its Application to a Multi-round Contention Resolution Scheme

  • Jang, Seowoo;Choi, Jin-Ghoo;Yoon, Sung-Guk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4259-4271
    • /
    • 2016
  • With the increased popularity of IEEE 802.11 WLAN, the density of the WLAN devices per access point has also increased, resulting in throughput performance degradation. One of the solutions to the problem is improving the protocol efficiency by a using multi-round contention scheme. This paper first discusses how to estimate the number of contending stations in a WLAN network by using minimum elapsed backoff counter values that can be easily monitored by each station. An approximate closed form expression is derived for the number of active contending stations using the smallest backoff counter value in the network. We then apply this result to adapt the number of contending rounds according to the network loading level to enhance the throughput performance of a multi-round contention scheme. Through simulation, we show that the accuracy of the estimation algorithm depends on the contention parameters of W and the number of backoff counter observing samples, and found a reasonable value for each parameter. We clearly show that our adaptive multi-round contention scheme outperforms the standard contention scheme that uses a fixed number of rounds.

COMPARATIVE STUDY ON THE MARGINAL BONE LOSS OF IMMEDIATE NONSUBMERGED AND SUBMERGED ENDOSSEOUS DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKETS OF DOGS (발치후 즉시 매식한 Nonsubmerged와 Submerged 임플랜트의 변연골 흡수양상에 관한 비교연구)

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.255-264
    • /
    • 1997
  • The conventional osseointegration protocol calls for waiting up to 12 months for ossification of an extraction socket to heal before placing an endosseous implant. In this study, the possibility of placing a pure titanium implant directly into an extraction socket immediately after extraction was investigated. And the marginal bone loss of immediate nonsubmerged and submerged endosseous dental implants placed into extraction sockets was also compared. Pure titanium Nobelpharma Branemark implants and solid screw type ITI implants were placed into premolar extraction sockets of two adult dogs and allowed to heal for a period of 3 months, followed by functional loading of the implant. Radiographic examination was performed before implantation, immediately after implantation and 3, 6, 9, 12 months after implantation. The results obtained were as follows : 1. Immediately placed nonsubmerged ITI implants and submerged Branemark implants showed favorable radiographic osseointegration status and there were minimum marginal bone loss. 2. There were no significant differences in radiographic finding of osseointegration between conventional and immediate implantation. 3. Gingival tissue around implants showed more inflammatory signs than that of adjacent natural teeth. This study suggest that pure titanium Branemark implants and submerged ITI implants have the potential to integrate when placed immediatly after extraction of the teeth and warrants further investigation.

  • PDF

Solid-Phase Extraction of Caffeine and Catechin Compounds from Green Tea by Caffeine Molecular Imprinted Polymer

  • Jin, Yinzhe;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.276-280
    • /
    • 2007
  • In this work, caffeine and some catechin compounds + C, EC, EGC, and EGCG were extracted from green tea by using molecular imprinted polymers (MIP) as sorbent materials in a solid-phase extraction (SPE) process known as MISPE (molecular imprinted solid-phase extraction). For synthesis of MIP, caffeine was employed as the template, MAA as the monomer, EGDMA as the crosslinker, and AIBN as the initiator. A solution of caffeine (0.2 mg/mL in methanol) was utilized in the solid extraction cartridges following loading, washing, and elution procedures with acetonitrile, methanol, and methanol-acetic acid (90/10, %v/v) as the solvents, respectively. This solid-phase extraction protocol was applied for the extraction of caffeine and some catechin compounds from green tea. A comparison was made between the results obtained with the MIP cartridges and a traditional C18 reversed-phase cartridge. It was thereupon found that the recovery of caffeine by the MIPbased sorbent used in this work was almost two and four times greater than that by a commercially available C18 material. A quantitative analysis was conducted by high performance liquid chromatography (HPLC) using a C18 column (5 μm, 250 × 4.6 mm) with methanol/water (40/60, %v/v) as the mobile phase at a flow rate of 0.5 mL/min.

The Effects of Knee Joint Taping Yherapy on ${\beta}$-endorphin and Serotonin of Pain Substances of Blood (슬관절 테이핑요법이 혈중통증물질인 ${\beta}$-endorphin과 serotonin에 미치는 영향)

  • Yang, Kyung-Han;Han, Jong-Man;Yoo, Wang-Keun
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.12 no.2
    • /
    • pp.185-195
    • /
    • 2008
  • The purpose of this investigation is comparing two groups one applied with taping therapy the other with controlled causes variation in pain substances of blood ${\beta}$-endorphin, serotonin with taping therapy. 12 male students of S college divided into two groups each 6 experimental and controlled with no history of flexion and extention of lower extremity focused on knee joint. Experimental group applied with elastic taping before experiment at quadriceps, calf muscles, hamstrings and tibialis anterior, controlled group didn't applied any taping therapy. Bruce protocol of maximal progressive loading exercise implemented 5 minutes after blood samples were extracted. And 5 minutes after the exercise blood samples also were taken and made investigation. Data before and after investigation were operated on SPSS Ver. 12.0 for Window(Kor.). P value 0.05. The affirmative effects of this investigation was proved with increased ${\beta}$-endorphin and decreased serotonin that cause reducing pain.

  • PDF

GIS AND WEB-BASED DSS FOR PRELIMINARY TMDL DEVELOPMENT

  • Choi, Jin-Yong;Bernard A. Engel;Yoon, Kwang-Sik
    • Water Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.19-30
    • /
    • 2003
  • TMDL development and implementation have great potential fur use in efforts to improve water quality management, but the TMDL approach still has several difficulties to overcome in terms of cost, time requirements, and suitable methodologies. A well-defined prioritization approach for identifying watersheds of concern among several tar-get locations that would benefit from TMDL development and implementation, based on a simple screening approach, could be a major step in solving some of these difficulties. Therefore, a web-based decision support system (DSS) was developed to help identify areas within watersheds that might be priority areas for TMDL development. The DSS includes a graphical user interface based on the HTML protocol, hydrological models, databases, and geographic information system (GIS) capabilities. The DSS has a hydrological model that can estimate non-point source pollution loading based on over 30 years of daily direct runoff using the curve number method and pollutant event mean concentration data. The DSS provides comprehensive output analysis tools using charts and tables, and also provides probability analysis and best management practice cost estimation. In conclusion, the DSS is a simple, affordable tool for the preliminary study of TMDL development via the Internet, and the DSS web site can also be used as an information web server for education related to TMDL.

  • PDF

Feasibility of Estimating Rut Resistance of SMA Mixture by Static Loading Test Using Confined Specimen (공시체 구속 상태에서 정하중 시험에 의한 SMA 혼합물의 소성변형 저항성평가 가능성)

  • Kim, Sungun;Choi, Chang-jeong;Kim, Kwang W.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.43-53
    • /
    • 2019
  • It is well-known fact that the stone-mastic asphalt (SMA) mixture has shown superior rut resistance, compared with the dense-graded asphalt (DGA) mixture in highway pavements. However, the SMA is measured to be inferior to DGA mixes when tested by well-known high-temperature test methods, such as the wheel tracking (WT), asphalt pavement analyzer, the Marshall Stability and Kim Test. Therefore, this study examined the reasons why it was measured to be inferior, and devised a potential procedure by which the superiority of SMA could be measured at $60^{\circ}C$. The strength against deformation ($S_D$), which was known to show very high correlation with WT results for DGA mixes, was measured by the Kim Test on the specimen confined in the compacted mold. In standard Kim Test, which used the specimen without confinement, the DGA was measured to show higher $S_D$ than the SMA. But by confining specimen, it was found that the $S_D$ of SMA was measured to be higher than that of DGA. Therefore, the confined static test protocol devised in this study was found to be feasible for evaluating rut resistance of SMA mix.

Cyclic behavior of self-centering braces utilizing energy absorbing steel plate clusters

  • Jiawang Liu;Canxing Qiu
    • Steel and Composite Structures
    • /
    • v.47 no.4
    • /
    • pp.523-537
    • /
    • 2023
  • This paper proposed a new self-centering brace (SCB), which consists of four post-tensioned (PT) high strength steel strands and energy absorbing steel plate (EASP) clusters. First, analytical equations were derived to describe the working principle of the SCB. Then, to investigate the hysteretic performance of the SCB, four full-size specimens were manufactured and subjected to the same cyclic loading protocol. One additional specimen using only EASP clusters was also tested to highlight the contribution of PT strands. The test parameters varied in the testing process included the thickness of the EASP and the number of EASP in each cluster. Testing results shown that the SCB exhibited nearly flag-shape hysteresis up to expectation, including excellent recentering capability and satisfactory energy dissipating capacity. For all the specimens, the ratio of the recovered deformation is in the range of 89.6% to 92.1%, and the ratio of the height of the hysteresis loop to the yielding force is in the range of 0.47 to 0.77. Finally, in order to further understand the mechanism of the SCB and provide additional information to the testing results, the high-fidelity finite element (FE) models were established and the numerical results were compared against the experimental data. Good agreement between the experimental, numerical, and analytical results was observed, and the maximum difference is less than 12%. Parametric analysis was also carried out based on the validated FE model to evaluate the effect of some key parameters on the cyclic behavior of the SCB.

A Prospective Clinical Trial on the Mg Oxidized Clinical Implants (마그네슘 양극산화 임플란트의 성공률에 관한 전향적 임상연구)

  • Im, So-Min;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Um, Heung-Sik;Lee, Jae-Kwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.25-39
    • /
    • 2011
  • In animal studies, Magnesium (Mg) - incorporated oxidized implants showed significant enhancement of the bone response. This prospective clinical trial was performed to investigate the success rate, implant stability and marginal bone loss of Mg oxidized clinical implant. The experimental protocol was approved by Institutional Review Board of the Gangneung-Wonju National University Dental Hospital. Fifty healthy patients had partial edentulism were included in this study. Mg oxidized clinical implants (Implant M, Shinhung, Korea) were installed and restored with conventional protocol. The patients were recalled at 1, 3, 6 months after functional loading. Implant stability quotient (ISQ) was measured and periapical radiographic images were obtained. Amount of marginal bone loss was calculated with calibrated images from periapical radiographs. Repeated measured analysis of variance and post hoc Tukey test were used to compare the mean ISQ and bone level. A total of 101 implants were analyzed. The mean ISQ values increased continuously with time lapse from 68.4 at fixture installation to 71.5 at 6 months after loading. Implant stability was correlated with gender, fixture diameter, bone quality and implant sites. The mean marginal bone loss during 6 months after loading was 0.26 mm. There was no failed implant and six-month success rate was 100%. Within the limitations of this study, the six-month success rate of Mg oxidized implant was satisfactory. The implant stability and marginal bone level were excellent. However, further longer clinical studies will be needed to confirm the success of Mg oxidized clinical implant.