• Title/Summary/Keyword: load test

Search Result 8,113, Processing Time 0.036 seconds

New approach for Ductility analysis of partially prestressed concrete girders

  • Radnic, Jure;Markic, Radoslav;Grgic, Nikola;Cubela, Dragan
    • Structural Engineering and Mechanics
    • /
    • v.70 no.3
    • /
    • pp.257-267
    • /
    • 2019
  • Expressions for the calculation of ductility index for concrete girders with different ratios of prestressed and classical reinforcement were proposed using load-displacement, load-strain and load-curvature relation. The results of previous experimental static tests of several large-scale concrete girders with different ratio of prestressed and classical reinforcement are briefly presented. Using the proposed expressions, various ductility index of tested girders were calculated and discussed. It was concluded that the ductility of girders decreases approximately linearly by increasing the degree of prestressing. The study presents an expression for the calculation of the average ductility index of classical and prestressed reinforced concrete girders, which are similar to the analysed experimental test girders.

A Study on the Inverter performance by Simulated Converter (시뮬레이터 컨버터에 의한 인버터 성능시험에 관한 연구)

  • Jho, J.M.;Jho, J.H.;Kim, S.N.;Lee, S.H.;Oh, S.H.;Lee, H.G.;Kim, Y.J.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.983-985
    • /
    • 2002
  • This paper is the machine that is able to estimate a new built power convertor in a production line. Generally, this machine test can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. But the proposal system is controlled to create some specific load characteristic needed for the test without any mechanical equipment. The suggested test stand consists only of a converter to be test and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. And then, to obtain a superior characteristic for dynamic reference used the feedforward control.

  • PDF

Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load (재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정)

  • Yoon, Sung Kee;Lee, Chy Hyoung;Koo, Bon Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • The domestic fire resistance performance test is conducted as a prescriptive design method such as quality test. In quality test there are 2 methods, unloaded fire resistance test and fire resistance test under load. In realistic, these tests, however, have problems with expense, time and diversity of structure. This study reviewed fire resistance performance of H-beam flexural member by thermal stress analysis using finite element ABAQUS program. This research is for the performance-based design reviewing applicability of domestic standard. As a result of this study, limit temperatures per each load ratio provied for proper performance of fire resistancy.

The Behavior of Bearing Capacity of Steel Pipe Piles Reinforced by Super Injection Grouting at Pile Tip (S.I.G 공법으로 선단보강된 강관말뚝의 지지거동)

  • Park, Young-Ho;Kim, Nag-Young;Yook, Jeong-Hoon;Choi, Jin-O
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.20-27
    • /
    • 2004
  • Reinforced twice than width of foundation with SIC under steel piles drived in cohesion soil and in the coal-limestone which heavily fractured. To analyze behaviour characteristic of steel piles, load transfer test was performed to steel piles attached with strain gauges to axial direction. After it passed 49days, dynamic load test was performed to set-up effect of steel piles bearing capacity. The results of test were compared to each other. According to the results, as the skin friction of steel pile was on the same condition, end bearing capacity of steel piles established on SIC solid of cemented milk in cohesion soil was three times than steel piles established on SIG solid of cemented milk in heavily fractured coal- limestone. After piles were driven and passes 49days, in case of piles on SIG solid of comented milk in cohesion soil the increaes of allowable bearing capacity was 442.9% and allowable bearing capacity of piles on SIG solid of cemented milk in heavily fractured coal-limestone increased 22.4%.

  • PDF

A Study on the Inverter performance test by Simulated Converter (시뮬레이터 컨버터에 의한 인버터 성능시험에 관한 연구)

  • Jho J.M.;Harm N.Y.;Kim D.G.;Lee S.J.;Kim S.N.;Lee H.G.;Han K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.765-768
    • /
    • 2003
  • In the end of a production line a new built power converter has to undergo a series of stress tests. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a converter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load.

  • PDF

Characteristics and Assessment of Printer Toner Adhesion (프린터 토너의 점착력 특성 및 평가 기법)

  • Lee, Jung-Eun;Kim, Kwang-Il;Kim, Hyun-Joon;Kim, Dae-Eun
    • Transactions of the Society of Information Storage Systems
    • /
    • v.5 no.2
    • /
    • pp.82-88
    • /
    • 2009
  • Understanding the adhesion behavior and characteristics of toner film is required to achieve image and text printing with high quality resolution. Toner can be considered as a thin film coating on a media such as paper or polymer film. Quantitative measurement of adhesion characteristics of the thin film is important to assess the reliability of the system. In this work the main objective was to investigate the adhesion characteristic between the toner and the media by ramp loading scratch test method. The scratch test may be used to obtain quantitative information about the adhesion of the film to the substrate. In the scratch test a diamond tip was used to scratch the surface of the toner film under an increasing normal load until the toner detached or fractured. The critical load (LC) was obtained from the experimental results. Also, the relationship between the critical load and the adhesive strength of the interface between the substrate and the toner was obtained by measuring the normal and tangential forces during the scratch test. Finally, theoretical analysis of the toner scratch characteristics was performed based on Benjamin and Weaver theory, Plowing model, and Laugier model.

  • PDF

After-fracture behaviour of steel-concrete composite twin I-girder bridges: An experimental study

  • Lin, Weiwei
    • Steel and Composite Structures
    • /
    • v.42 no.1
    • /
    • pp.139-149
    • /
    • 2022
  • To simplify the design and reduce the construction cost of traditional multi-girder structural systems, twin I-girder structures are widely used in many countries in recent years. Due to the concern on post-fracture redundancy, however, twin girder bridges are currently classified as fracture critical structures in AASHTO specifications for highway bridges. To investigate the after-fracture behavior of such structures, a composite steel and concrete twin girder specimen was built and an artificial fracture through the web and the bottom flange was created on one main girder. The static loading test was performed to investigate its mechanical performance after a severe fracture occurred on the main girder. Applied load and vertical displacement curves, and the applied load versus strain relationships at key sections were measured. To investigate the load distribution and transfer capacities between two steel girders, the normal strain development on crossbeams was also measured during the loading test. In addition, both shear and normal strains of studs were also measured in the loading test to explore the behavior of shear connectors in such bridges. The functions and structural performance of structural members and possible load transfer paths after main girder fractures in such bridges were also discussed. The test results indicate in this study that a typical twin I-girder can resist a general fracture on one of its two main girders. The presented results can provide references for post-fracture performance and optimization for the design of twin I-girder bridges and similar structures.

Development of Lightweight Plastic Formwork through Efficiency(Load) Test (경량 플라스틱 거푸집 개발 및 성능(하중재하) 시험)

  • Kang, Sin Hun;Lee, Changsu;Kwon, Woobin;Ahn, Heejae;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.10-11
    • /
    • 2020
  • Currently, the most used forms, such as euro form and aluminum form, has many problems. There are issues with noise of construction site because of existing forms' material and issues with safety because of heavy weight. To solve these problems, there are many researches on using plastic and composite materials on the formwork. However, plastic has lower tensile strength than the steel and aluminum and composite materials are expensive. Therefore, constructors are avoid to use the forms with new materials. The purpose of this study is to develop light-weight plastic form to solve these existing problems by using ABS with optimized design. To verify, the study measured the amount of deflection from developed form through a load test. The test result showed a deflection of 1.15mm when 1.4ton was loaded in the middle of form. The result of the study verified that the usage of ABS and optimized design effectively reduced the weight and noise. Also, it's performance was verified through the load test.

  • PDF

Study on the possible application of Vibrated and Rolled reinforced concrete pipe to vertical.crossing water distribution system (진동 및 전압 철근 콘크리트관의 종.횡단배수관 적용성 검토에 관한 연구)

  • Park Do-Kyong;Lee Myung-Kue;Yang Keek-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.2 s.20
    • /
    • pp.111-117
    • /
    • 2006
  • In case of carrying out vortical crossing water distribution system in expressways or general roads construction, VR(Vibrated and Rolled reinforced concrete) pipes are restricted because of their specification of reinforced spun concrete pipe or on-site made pipe. Therefore, in order to apply VR pipes to those constructions, through the structural behavior experiments of the pipes, VR pipes are compared and verified with reinforced spun concrete pipe and the results are obtained as the following. From the experiments and analyses of Pipe Stiffness(PS) of the pipes, cracking loading is approved to satisfy the KS regulations. Through a direct load test, the cracking loading strength and the maximum load test of VR pipe is larger compared with reinforced spun concrete pipe. Particularly, even if side weld is thin, there is no little change in the cracking strength of VR pipe. The results of the direct load test analysis show that the structural behavior of VR pipe is equivalent or higher compared with reinforced spun concrete pipe in performance and VR pipe could be used as the water distribution pipe for roads. In this study, through pipe stiffness, direct load test and load teat on earth, reinforced spun concrete pipe and VR pipe are compared. And as a result, the structural behavior of VR pipe is comprehensively excellent. From the structural behavior tests, VR pipe's section shows more thickness and has uniform characteristics so that VR pipe is considered more favorable than reinforced spun concrete pipe.

Estimation of Coefficient of Horizontal Subgrade Reaction by the Inverse Analysis on the Lateral Load Test Results (수평재하시험 역해석을 통한 수평지반반력계수 산정)

  • Ryu, Soo-Yong;Kwak, No-Kyung;Park, Min-Chul;Jeong, Sang-Guk;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.15-24
    • /
    • 2012
  • Even though decision of coefficient of horizontal subgrade reaction is important in analysis for pile under lateral load, the behavior of pile under lateral loading is estimated differently due to using established suggestion. Therefore this study estimates coefficient of horizontal subgrade reaction by using Chang's method or numerical inverse analysis method with the result of lateral load test. Then this study investigates the adequacy and reliability for coefficient of horizontal subgrade reaction. The analytical results of coefficient of horizontal subgrade reaction with lateral load test showed that coefficient of horizontal subgrade reaction with Chang's method was underestimated as compared with inverse analysis. Deformation modulus of foundation by Standard Specifications for Highway Bridges and Eo${\fallingdotseq}$1,400~1,600N showed similar range like range of coefficient of horizontal subgrade reaction with lateral load test.