• 제목/요약/키워드: load test

검색결과 8,113건 처리시간 0.036초

Performance Tests of an Induction Motor with Hexahedron HTS Bulk Bearing (고온초전도 벌크 베어링을 사용한 유도 전동기의 특성 시험)

  • 임형우;이광윤;박명진;차귀수;이지광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제52권6호
    • /
    • pp.286-290
    • /
    • 2003
  • The high temperature superconducting bulk can be used as the bearing of induction motors. This paper presents the fabrication and test results of an induction motor with superconducting bearings using HTS bulks. The bearing had eight hexahedron type YBCO bulks. Height, width and thickness of the HTS bulk were 30mm, 30mm and 10mm, respectively. Single phase induction motor was used to drive the shaft made of aluminum and the rotor of a conventional induction motor. To estimate the performance of the HTS bulk magnetic bearing, no load test, load test and Impact test were carried out. Load tests were performed by using air resistance caused by the shaft-mounted thin cylinder with buckets. Impact tests by axial direction and vertical direction impact showed that the vibration of the shaft gradually decayed. The induction motor with HTS bulk magnetic bearing rotated silently and smoothly throughout the tests. According to the test results, conventional bearings can be replaced with superconducting magnetic bearings made of HTS bulks.

Evaluation of Structural Test for Bottom End Piece Used for Nuclear Power Reactor (원자로용 하단고정체에 대한 구조시험 평가)

  • 김재훈;사정우;김덕회;손동성;임정식
    • Journal of the Korean Society of Safety
    • /
    • 제14권3호
    • /
    • pp.3-11
    • /
    • 1999
  • The atomic fuel rods between top and bottom end pieces of reactor need to be extended for high combustion rate of future-type fuel to increase the irradiation in the axial direction. For allowing axial extension of the fuel rods, the space between top and bottom end pieces should be expanded. Thus the thickness reduction of the flow plate is necessary. This study was carried out the mechanical strength test by using strain gages as a function of flow plate thickness, the existence of skirt and loading condition for the Korean Fuel Assembly(KOFA). The experimental apparatus was designed for load conditions, uniformly distributed load and displacement. Test method using whiffle tree of uniformly distributed load has been comparatively conservative. The test results were compared with those of finite element analysis and the test method on bottom end piece was established.

  • PDF

Test of an High Temperature Superconducting Power Transformer (고온초전도변압기의 특성시험)

  • Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Kim, U-Seok;Han, Song-Yeop;Ryu, Gyeong-U;Choe, Gyeong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제49권9호
    • /
    • pp.572-577
    • /
    • 2000
  • This paper describes the test results of a single phase 3kVA high temperature superconducting power transformer. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used. Among them two double pancake windings are connected in series for high voltage winding and the others are connected in parallel for low voltage winding. The rated voltage and current of primary winding and secondary winding are 220/110V. 13.7/27.3A. Fundamental characteristics are obtained through short circuit and no load test. The over load capability and characteristics are investigated.

  • PDF

Performance Evaluation of the HTS Bulk type Motor (고온초전도벌크형 전동기의 특성시험)

  • Sim, Jung-Wook;Lim, Hyoung-Woo;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • 제2권2호
    • /
    • pp.44-48
    • /
    • 2000
  • The high temperature superconducting bulk can be used as the rotor of an ac motor. This paper presents the fabrication and test results of a ac motor with HTS bulk rotor. The rotor of a conventional squirrel cage induction motor was replaced with cylinder type YBCO bulk. Height and outer diameter of the HTS bulk was 15mm and 46mm, respectively. Eddy current brake using aluminium disk was used to measure the torque of the HTS motor. No load test, locked rotor test and load test were performed to examine the characteristics of the HTS motor. Test results show the motor can rotate at synchronous speed without any special starting circuit. Maximum output power of the constructed HTS motor was 408W.

  • PDF

Structure Analysis and Loading Test of Torque arm for Driving Gear Unit of Unique Model (독자모델 감속구동장치 토크암의 구조해석 및 하중시험에 관한 연구)

  • Cha Soo-Deok;Choi Jin-Wook;Yu Jai-Il;Lee Min-Soo
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.211-215
    • /
    • 2004
  • This paper describes the result of structure analysis and load test of torque arm for driving gear unit. The purpose of the analysis and test is to evaluate an safety which torque arm shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Driving gear unit consist of gearbox and torque arm. Both components, torque arm is significant component subjected to the vehicle and motor loads. The evaluation methode is used the FEM analysis, static and fatigue test. The test results have been very safety and stable for design load conditions.

  • PDF

Equivalent Circuit Constants and Characteristics Calculation of LIM by Lock test (구속시험에 의한 선형 유도 전동기의 등가회로 정수 산정 및 특성 계산)

  • 김규탁;강규홍;최태희;이정규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • 제43권4호
    • /
    • pp.580-586
    • /
    • 1994
  • The equivalent circuit of linear induction motor is generally expressed as the same that of rotary induction motor. However, it is almost impossible to perform the no-load test for LIM, because it needs a special equipment for synchronous speed. Therefore, a new method is reqnired to calculate the performance of the LIM without the no-load test. In this paper, The new method which does not need no-load test for the chanracteristics analysis of LIM is proposed. The equivalent circuit of LIM is chosen and the method if determining its constants from results of the lock test is discussed. The calculated results were satisfied by compare with experimental and conventional method results.

Half-Scaled Substructure Test of a Transmission Tower Using Actuators (엑츄에이터를 이용한 송전철탑의 1/2 축소부분실험)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.178-188
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, it was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

  • PDF

A Study on the Evaluation of Long Term Stability of Brinell Standard Hardness Tester and Automatic Indentation Measurement System and Optimum Test Condition (브리넬 경도 표준 시험기 및 압입자국 자동 측정 장치의 장기 안정도 평가와 최적 시험조건에 관한 연구)

  • Bahng, G.W.;Tak, Nae-Hyung;Hwang, N.M.
    • Journal of the Korean Society for Heat Treatment
    • /
    • 제13권1호
    • /
    • pp.10-15
    • /
    • 2000
  • Evaluation of long term stability of the Brinell standard hardness tester was carried out to secure its application as a national standard in Brinell hardness. Accuracy and repeatability in load application were tested through evaluating errors in hardness measurement of certified reference blocks. All of those requirements in KS as well as ISO specifications were satisfied by this standard hardness tester. In addition to this, long term stability test of automatic indentation measurement system was carried out. The scattering range was almost the same with its error range. To figure out an optimum test condition for better repeatability and long term stability, the effect of load variation, load application speed and time have been studied using orthogonal array experimental plan. It was found that the best combination is $30{\mu}m/s$ of load application speed and 25 seconds of load application time.

  • PDF

An Experimental Study on the Relationship between Deformation and Relative Settlement for Weathered-granite (화강풍화토의 변형계수와 상대침하 관계식에 관한 실험적 연구)

  • Park, Yong-Boo
    • Land and Housing Review
    • /
    • 제4권1호
    • /
    • pp.125-131
    • /
    • 2013
  • To predict the real bearing capacity and settlement of the shallow foundation the plate load test results were used. But there is no field estimation method about igneous weathered soil and rock. Therefore, to predict the settlement equation, the plate load test about igneous weathered soil and rock was done in this study. To analyze the load ~ relative settlement curve by normalization, it did not use normal analysis method, but the load ~ relative settlement (s/B, s : settlement, B : breadth of plate) was used. As a result of normalization by load ~ relative settlement conception, the curve was regular regardless of plate diameter and it was suggested the relationship of in-situ soil condition and results.

Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation (강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험)

  • Kim, Dong-Hyuk;Hong, Hi-Ki;Yoo, Ho-Seon;Kim, Ook-Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제18권12호
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.