• Title/Summary/Keyword: load shift keying

Search Result 7, Processing Time 0.025 seconds

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

Bidirectional Magnetic Wireless Communication System under Inductive Power Transfer capable of Amplitude-Shift Keying(ASK) Modulation Control (자기유도 무선전력전송시 진폭편이변조 제어가 가능한 양방향 자기장 무선통신 시스템)

  • Choi, Byeung-Guk;Lee, Eun-Soo;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.275-281
    • /
    • 2016
  • A novel bidirectional magnetic wireless communication system is proposed in this study. This system provides the communication capability between the source and load sides by high-frequency signal while wireless power is transferred. Contrary to the conventional wireless communication systems using complex IC circuit and active components, the proposed system is simply composed of passive components. It is practical and beneficial for environmental robustness, cost effectiveness, and simple implementation. The detailed static analysis of the proposed system for power and communication lines is established. The proposed system is experimentally verified, and results show that a 0.1 voltage gain for communication line is obtained while a 2.0 voltage gain for the power line is achieved. The proposed system is adequate for practical applications as it allows the inductive power transfer system to wirelessly and easily communicate between the source and load sides.

Data Transmission through Power Line of Smart Transmitter

  • Kim, Jong-Hyun;Kang, Hyun-Kook;Seong, Poong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.471-476
    • /
    • 1996
  • In this study, the method to use the phase shift keying (PSK) communication technique in smart transmitter is presented. In nuclear applications. smart transmitters for various parameters are expected to improve the accuracy of measurement and to reduce the load of calibration work. The capability of communication in field level is the most important merit of the smart transmitter. The most popular method is using of digital and analog techniques simultaneously - transmitting measurements from the field at 4∼20mA while modulating the current to carry digital information in both directions over the same twisted pairs. Conventional smart transmitters use the frequency shift keying (FSK) method for digital communication. Generally, however, the FSK method has the speed limit at 1200 bps. Amount of information to transmit becomes increasing as the processing technique is improved. The PSK method is noticeable alternative for high speed digital communication, but it has non-zero DC component. In order to use the PSK method in the field transmission with smart transmitter, the method to remove the DC component is studied in this work.

  • PDF

The Modem Manufacture of Power Line Communication for Power Load Control (전력부하제어를 위한 전력선통신모뎀제작)

  • Lee, Sam-Jin;Yang, Seung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1132-1134
    • /
    • 2001
  • 전력선통신 변조방식 중 FSK(Frequency Shift Keying)변조방식을 이용하여 컴퓨터와 RS232케이블로 전력선모뎀과 연결하여 컴퓨터의 데이터신호를 전력라인으로 직접 송신할 수 있게 하였으며, 수신부에서 데이터신호를 검출하여 가전기기의 전원을 ON/OFF 하였다.

  • PDF

Implementation of Wireless Charger with the Function of Auto-Shutdown for fully Implantable Middle Ear Hearing Devices (완전 이식형 인공중이를 위한 자동 충전종료형 무선 충전장치의 구현)

  • Lee, Jang-Woo;Lim, Hyung-Gyu;Jung, Eui-Sung;Han, Ji-Hun;Lee, Seung-Hyun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.539-548
    • /
    • 2007
  • In the paper, a wireless charger with the function of auto-shutdown for fully implantale middle ear hearing devices (F-IMEHD) has been designed. The wireless charger can communicate with an implant module to be turned off automatically shutdown after an internal rechargeable battery has been fully-charged by electromagnetic coupling using two coils. For the communication with an implant module, the wireless charger uses the load shift keying (LSK) method. But, the variation of the mutual inductance due to the different distance between two coils can cause the communication error in receiving the fully-charged signal from an implant module. To solve the problem, the implemented wireless charger has a variable reference generator for LSK communication. The wireless charger generates proper level of the reference voltage for a comparator using an ADC (analog-to-digital converter) and a DAC (digital-to-analog converter). Through the result of experiment, it has been confirmed that the presented wireless charger can detect signals from implantable module. And wireless charger can stop generating electromagnetic flux after an implanted battery has been fully charged in spite of variable coil distance according to different skin thickness.

Implementation of Control System for Remote Load using Power line Communication (전력선 통신을 이용한 원격 부하제어 시스템의 구축)

  • Kim Ho;Lee Won-Sun;Jeon Hee-Jong;Park Jong-chan
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.685-688
    • /
    • 2002
  • This paper deals with new scheme of remote load control management system with communication from RCU to controller using power line Power line communication is useful for economical data link but various problems and limitations are caused in using power lines for communications channel. A power line is not so good in the commercial electrical power, and its load noise and high frequency noise are so much. To decrease these noise, we used the FSK(Frequency Shift Keying) modulation method. The experimental results show that the proposed system in this paper is compatible with the conventional system with low cost and the feasibility is very high for new or remodeling plant.

  • PDF

Design and Performance Evaluation of Load-Modulation MIMO System Using High-Order Modulation (고차 변조를 사용하는 Load-Modulation MIMO 시스템 설계와 성능 평가)

  • Lee, Dong-Hyung;An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.11
    • /
    • pp.2121-2130
    • /
    • 2015
  • In this paper, we analyze LM-MIMO (load-modulation multiple-input multiple-output) system with single RF chain. And then, we confirm that load modulation technique can support generation of high-order m-PSK modulation and m-QAM modulation in LM-MIMO system. Finally we evaluate performance of LM-MIMO system with load modulation. Conventional MIMO system requires a number of RF chains for expansion of MIMO dimension. A number of RF chains can cause various problems. On the other hand, although LM-MIMO system is expanded, LM-MIMO system requires single RF chain only. Therefore, LM-MIMO system has low-complexity and low power consumption. As results, we can confirm that load modulation of T-model can modulate high-order m-PSK and m-QAM singal. Also, we can confirm that $4{\times}4$ LM-MIMO system using load modulation has a similar performance to conventional $4{\times}4$ MIMO system.