• Title/Summary/Keyword: load regulation

Search Result 528, Processing Time 0.025 seconds

Implementation of a Sliding Mode Controller for Single Ended Primary Inductor Converter

  • Subramanian, Venkatanarayanan;Manimaran, Saravanan
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.39-53
    • /
    • 2015
  • This paper presents the regulation of the output voltage and inductor currents in a Single Ended Primary Inductor Converter (SEPIC), operating in the continuous conduction mode (CCM) using a sliding mode controller. Owing to the time varying nature of the SEPIC converter, designing a feedback controller is a challenging task. In order to improve the dynamic performance of the SEPIC, a Sliding Mode Controller (SMC) is developed. The developed SMC is designed by using a state space average model. The performance of the developed controller with the SEPIC converter is validated at different working conditions through Matlab simulations. It is also compared with the performance while using a PI controller. The results show that the designed controller gives very good output voltage regulation under different operating conditions such as a varying input voltage, changes in the load and component variations. A 48V, 46W experimental setup for has been developed in an analog platform to validate the performance of the proposed SMC.

Minimum Time Regulation of DC-DC Converters in Damping Mode with an Optimal Adjusted Sliding Mode Controller

  • Jafarian, Mohammad Javad;Nazarzadeh, Jalal
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.769-777
    • /
    • 2012
  • In this paper, a new development in the time optimal control theory in sliding mode control systems for multi-quadrant buck converters with a variable load is presented. In general, the closed-loop time optimal control system is applied to multi-quadrant buck converters for output regulation, so that an optimal switching surface is obtained. Moreover, an adjusted optimal sliding mode controller is suggested which adjusts the controller parameters to give an optimal switching surface. In addition, a description of the transient response of the closed-loop system is proposed and used to damp any output or input disturbances in minimum time. Numerical simulations and experimental results are employed to demonstrate that the output regulation time and transient performances of dc/dc converters using the proposed technique are improved effectively when compared to the classical sliding mode control method.

NEURAL NETWORK CONTROLLER FOR A PERMANENT MAGNET GENERATOR APPLIED IN WIND ENERGY CONVERSION SYSTEM

  • Eskander Mona N.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.656-659
    • /
    • 2001
  • In this paper a neural network controller for achieving maximum power tracking as well as output voltage regulation, for a wind energy conversion system(WECS) employing a permanent magnet synchronous generator, is proposed. The permanent magnet generator (PMG) supplies a dc load via a bridge rectifier and two buck-boost converters. Adjusting the switching frequency of the first buck-boost converter achieves maximum power tracking. Adjusting the switching frequency of the second buck-boost converter allows output voltage regulation. The on-times of the switching devices of the two converters are supplied by the developed neural network(NN). The effect of sudden changes in wind speed ,and/or in reference voltage on the performance of the NN controller are explored. Simulation results showed the possibility of achieving maximum power tracking and output voltage regulation simultaneously with the developed neural network controller. The results proved also the fast response and robustness of the proposed control system.

  • PDF

An Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW (5상 5kW 표면부착형 영구자석 동기발전기 운전특성)

  • Jung, Hyung-Woo;Kim, Min-Huei;Song, Hyun-Jik;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.9-16
    • /
    • 2013
  • This paper presents an operating characteristics of the 5-phase 5kW with developed the surface permanent magnetic synchronous generato (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. There are shown a amplitude and waveform of the generated electromotive force, in FFT analysis of harmonics, within output voltages, and reviewing a experiment results in no-load test, resistive load, and inductive load using 5-phase induction motor by variable output frequency. The operating characteristics of the developed manufacturing generator include voltage regulation, efficiency, power factor, THD, and so on at rated load.

Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application (무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

Design of an improved PID controller for DC/DC boost pourer converter with inductor resistance under load variation (부하변동과 인덕터 저항을 고려한 DC/DC 승압 컨버터의 개선된 PID 제어기 설계)

  • Kim, In-Hyuk;Jeong, Goo-Jong;Son, Young-Ik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.85-87
    • /
    • 2009
  • This paper presents a new PID controller for a DC/DC boost converter model that has a parasitic inductor resistance. In order to maintain the robust output regulation property under load variations the proposed controller is designed by using an additional state variable developed via a parallel-damped passivity-based control approach. Simulation results using Matlab/Simulink SimPowerSystems compare the performances of the proposed controller with a conventional PI controller for reference step changes and load uncertainties.

  • PDF

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 한석우;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF

A NEW INSTANTANEOUS VOLTAGE COMPENSATOR WITH FUNCTION OF ACTIVE POWER FILTERING

  • Lee, Seung-Yo;Lee, Jeong-Min;Lee, Sang-Yong;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.780-784
    • /
    • 1998
  • A novel active input unbalance voltage compensator with harmonic current compensating capability is proposed and the operating principle of the proposed system is presented in the 3-phase power system. The proposed system performs both the voltage regulation of the load and the compensation of the harmonic currents generated due to nonlinear load such as diode rectifier. The system to compensate unbalanced voltage and hramonic currents is composed of a 3-phase voltage source inverter, LC filter, series transformer and passive devices at the load side of the line. The compensating voltage to regulate the load voltage and to remove the harmonic current components is transmitted to the line by the series transformer. The validity of the line by the series transformer. The validity of the proposed system is proved by the results of computer simulation.

  • PDF

A Situations and Improvements on the Rail Freight System (철도화물수송체계의 현황과 개선방안)

  • 이용상
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.37-48
    • /
    • 2004
  • In this paper, I explain the situations and problems which are focused on the rail freight system. We have a many problems, which have been showed the long freight logistics time, and inadequate fare system. And rail freight system does not have a efficient marketing system, and unit load system. Therefore rail freight has been decreased modal share, which is estimated from 9.65% in 1995 to 6.25% in 2001(ton base). Recently, EU nations and America rail freight system reveals a good outcome, which keeps the balance in the black. The main factors which go into the black, is the enlargement the investment in rail freight and efficient management focusing on the unit load system, fare system, and personnel management. I suggest the several improvement ways, which will be helpful to advance the rail freight system. Fistly, I suggest the speed up the freight rail and efficient fare system. Secondly, I propose the unit load system and the regulation the truck focusing on curtailment of the social cost. Lastly, I make an overture of establishment the comprehensive logistics system.

LDO Regulator with Improved Transient Response Characteristics and Load Transient Detection Structure (Load Transient Detection 구조 및 개선된 과도응답 특성을 갖는 LDO regulator)

  • Park, Tae-Ryong
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.124-128
    • /
    • 2022
  • Conventional LDO regulator external capacitors can reduce transient response characteristics such as overshoot and undershoot. However, the capacitorless LDO regulator proposed in this study applied body technology to the pass transistor to improve the transient response and provide excellent current drive capability. The operating conditions of the proposed LDO regulator are set to an input voltage that varies from 3.3V to 4.5V, a maximum load current of 200mA, and an output voltage of 3V. As a result of the measurement, it was found that when the load current was 100 mA, the voltage was 95 mV in the undershoot state and 105 mV in the overshoot state.