• 제목/요약/키워드: load management

검색결과 2,146건 처리시간 0.027초

확산 Markov 프로세스 모델을 이용한 Queueing System 기반 지능 부하관리에 관한 연구 (A Study on the Intelligent Load Management System Based on Queue with Diffusion Markov Process Model)

  • 김경동;김석현;이승철
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.891-897
    • /
    • 2009
  • This paper presents a novel load management technique that can lower the peak demand caused by package airconditioner loads in large apartment complex. An intelligent hierarchical load management system composed of a Central Intelligent Management System(CIMS) and multiple Local Intelligent Management Systems(LIMS) is proposed to implement the proposed technique. Once the required amount of the power reduction is set, CIMS issues tokens, which can be used by each LIMS as a right to turn on the airconditioner. CIMS creates and maintains a queue for fair and proper allocation of the tokens among the LIMS requesting tokens. By adjusting the number tokens and queue management policies, desired power reduction can be achieved smoothly. The Markov Birth and Death process and the Balance Equations utilizing the Diffusion Model are employed for evaluation of queue performances during transient periods until the static balances among the states are achieved. The proposed technique is tested using a summer load data of a large apartment complex and give promising results demonstrating the usability in load management while minimizing the customer inconveniences.

오염총량관리 할당부하량 초과지역의 최종 평가기준에 관한 연구 (A Study on the Final Evaluation Criteria of Allocation Exceedance Regional in Total Maximum Daily Load)

  • 오승영;한미덕;김석규;안기홍;김옥선;김용석;박지형
    • 한국물환경학회지
    • /
    • 제32권5호
    • /
    • pp.450-457
    • /
    • 2016
  • The Total Maximum Daily Load (TMDL) is a watershed management system that involves the establishment of the target water quality, the calculation of permission loading (allocation loading), and the control of total pollutants for each unit watershed. Allocation loading is assessed through the comprehensive implementation assessment of the previous year's plan. Assessment results are used for follow-up management measures such as the limit of development and updating of TMDL Management Implementation Plans for the next planning period. Although detailed assessment criteria are important, they are not currently available. Therefore, we suggested assessment criteria by comparing two methods('integration method' and 'separation method') using combination point and non-point discharge loading. We also examined the penalty criteria considering controllable load local government and updating methods of the TMDL Management Implementation Plan for the next planning period.

${\cdot}$난방 시스템의 부하관리 프로그램 적용 타당성 검토 (feasibility Study in Application on Load Management of Cooling or Heating Systems)

  • 손학식;김회철;김형중;허동렬;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.686-688
    • /
    • 2004
  • We suggest that the core factor which can be established successfully pushing ahead with domestic load management program is finding and keeping management of controllable load resources. We know that load management is mostly the maximum demand power management and participation of DLC program. This paper suggests the way coping with load management suggesting model which air conditioning and heating load facilities are applied to DU program.

  • PDF

원격제어 에어컨 개발 보급현황 및 향후전망 (A development of direct load control system for air-conditioner)

  • 강원구;김충환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF

천연가스 부하관리 (Load Management of Natural Gas)

  • 조금남;김용찬;홍희기;김상노;김인택;전호철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.264-269
    • /
    • 2006
  • Efficient load management on natural gas is strongly required to allow stable and reasonable energy use. The present study investigated domestic and international cases for demand management of natural gas. The directions of load management were discussed. The reasonable evaluation methods of demand management were analyzed and specific evaluation items were suggested.

  • PDF

수계 오염총량관리제와 환경영향평가제도의 통합운영방안 (Integration of Total Pollution Load Management System and Environmental Impact Assessment related System)

  • 이종호
    • 환경영향평가
    • /
    • 제12권5호
    • /
    • pp.359-367
    • /
    • 2003
  • The total pollution load management system of watershed has been implemented upon Special Law pertaining to the Han River Watershed Water Quality Improvement and Residents Support, Special Law pertaining to the Nakdong River Watershed Water Management and Residents Support, Special Law pertaining to the Youngsan River Watershed Water Management and Residents Support, and Special Law pertaining to the Seomjin River Watershed Water Management and Residents Support in Korea since 2002. But many other similar systems with total pollution load management system of watershed are being operated separately or independently, even though its purpose is nearly same with those of the total maximum pollutants load management in Law on Water Quality Environmental Protection, environmental impact assessment(EIA) in Law of Impact Assessment on Environment, Transportation and Disaster and Pre-environmental assessment of Environmental Policy Act. Therefore the contents of total pollution load management system of watershed and many other related systems could be overlapped and at some times have inconsistency among them. This study suggests first the integrated operation of total pollution load management system of watershed, EIA, pre-environmental assessment, urban planning, and sewage planning and secondly EIA system development by integration of EIA and pre-environmental assessment and strategic environmental assessment(SEA).

에어컨부하 직접제어시스템 실증시험 및 운용방안에 관한 연구 (The Study on the Field test and Operational Method of a Direct Load Control System for Air conditioner)

  • 강원구;김충환;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2825-2827
    • /
    • 2000
  • In electric power industry. load balance has been one of the most fundamental and important management goals. Therefore. the strategy to achieve high quality load management now includes load balance besides the stabilization of electricity supply and quality management of electricity. Amongst many techniques of load management. direct load management has been actively studied and utilized to increase power facility and peak load suppression. Higher peak load situation is appeared during summer than during winter in Korea. and approximately 20% of the peak load is due to the load for air-conditioning. To cope with this peak load problem during summer KEPCO is performing a research project to develop a system to remotely control air-conditioning load using wireless communication. Currently, applicable facilities are limited to small-scale air-conditioning facility that has less than 2KW power capacity. This paper described the 1st year of efforts made in the study.

  • PDF

단기 전력우급계획에서의 부하관리 효과 분석연구 (The Analysis of Load Management Effect in Shor-Term Generation Expansion Planning)

  • 김준현;정도영
    • 대한전기학회논문지
    • /
    • 제41권9호
    • /
    • pp.994-1002
    • /
    • 1992
  • With regard to price elasticity and cross elasticity of electricity, optimal generation expansion planning method including load management effect is suggested. In addition, optimal peak time price can be determined simultaneously, and we adopt peak time tariff as load management strategy. Instead of using hourly marginal demand curves where we can get customer surplus, we used chronological load curve with constraints to preserve social welfare. This method is proved useful in short-term generation expansion planning.

  • PDF

큐잉모델에 기초한 자율 지능 부하 관리 시스템 연구 (A Study of Autonomous Intelligent Load Management System Based on Queueing Model)

  • 이승철;홍창호;김경동;이인용;박찬엄
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.134-141
    • /
    • 2008
  • 본 논문은 전력회사와 수용가가 실시간으로 상호 협력하면서 효율적으로 여름철 냉방부하를 관리하여 첨두부하를 저감하기 위한 기법에 대하여 기술한다. 전력회사가 필요 관리량을 수용가 측에 요청하면 부하관리 요청을 받은 수용가, 예를 들면 대규모 아파트 단지의 중앙 지능관리 서버(Central Intelligent Management Server: CIMS)가 자율적인 관리를 통하여 요구받은 관리전력 이내로 부하율을 조정하도록 한다. 부하율을 관리하기 위한 수단으로CIMS는 필요 관리 부하전력에 따라 냉방기를 가동할 수 있는 권리에 해당하는 적정 수의 토큰(Token)을 발행하고 각 세대내의 냉방기를 제어할 수 있는 다수의 로컬 지능관리 서버(Local Intelligent Management Server: LIMS)들이 각 집안의 상황에 따라 냉방기를 가동하기 원할 경우에 전체 관리 서버에게 냉방기를 가동할 수 있는 권리에 해당하는 토큰을 요청하도록 한다. CIMS는 LIMS들의 토큰 요청을 관리하기 위한 큐(Queue)를 구성하여 관리하고 토큰을 요구한 각 LIMS들은 토큰을 할당받는 대로 자신이 담당하는 세대내의 냉방기를 가동하고 일정조건이 만족되면 자율 또는 타율로 토큰을 반납하여 큐에서 기다리는 다른 LIMS들에게도 토큰이 할당될 수 있도록 한다. 큐 운영 정책에 다양한 냉방기 운용 환경 정보를 반영하고 CIMS와 LIMS간에 원만한 상호 협력을 위하여 지능형 멀티 에이전트(Multi-Agent) 시스템으로 구성하고 이들을 계층구조의 네트워크로 연결하였다. 제안하는 기법을 서울의 한 아파트단지의 여름철 전력수요 데이터를 예로 하여 예상되는 대기 시간과 지원 받을 수 있는 전력요금 규모를 산정해 보았으며, 비교적 적은 수용가의 불편으로 큰 부하관리 효과를 얻을 수 있는 것을 알 수 있었다.

효과적인 오염총량관리를 위한 데스크탑 기반의 LDC 평가 시스템 개발 (Development of Desktop-Based LDC Evaluation System for Effectiveness TMDLs)

  • 류지철;황하선;이성준;김은경;김용석;금동혁;임경재;정영훈
    • 한국농공학회논문집
    • /
    • 제58권4호
    • /
    • pp.67-74
    • /
    • 2016
  • Load Duration Curve (LDC) can be used as a method for load management of point and non-point pollution source because the LDC easily assesses the water quality corresponding to hydrological changes in a watershed. Recently, the application of LDC to total pollution load management is a growing interest in Korea. In this regard, A desktop-based LDC assessment system was developed in this study to provide convenience to users in water quality evaluation. The developed system can simply produce the LDC by using streamflow and water quality data involved in its database. Also, The system can quantitatively inform the success or failure of the achievement for a target water quality at monthly scale. Furthermore, seasonal water quality and point/non-point pollution load in a watershed can be estimated by this system. We expect that the developed system will contribute to establish local and national policies regarding water management and total pollution load management because of its advantages such as the pollution tracking investigation and the analysis of water quality and pollution loading amount in an ungauged watershed.