• Title/Summary/Keyword: load impedance

Search Result 412, Processing Time 0.026 seconds

A Trip Coil Fault Detection of Circuit Breaker (차단기 트립코일 이상감지 장치)

  • Youn, Ju-Houc;Lee, Jong-Hun;Park, Noh-Sik;Lee, Dong-Hea
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

Efficiency Enhancement of Wireless Power Transfer with Optimum Coupling Mechanism for Mid-range Operation

  • Anowar, Tanbir Ibne;Kumar, Narendra;Ramiah, Harikrishnan;Reza, Ahmed Wasif
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1556-1565
    • /
    • 2017
  • This paper depicts the design, implementation and analysis of efficient resonant based wireless power transfer (WPT) technique using three magnetic coupled coils. This work is suitable for mid ranged device due to small form factor while minimizing the loading effect. A multi turned loop size resonator is exploited for both the transmitter and receiver for longer distance. In this paper, class-E power amplifier (class-E PA) is introduced with an optimum power tracking mechanism of WPT system to enhance the power capability at mid-range with a flat gain. A robust method of finding optimum distance is derived with an experimental analysis of the designed system. In this method, the load sensitive issue of WPT is resolved by tuning coupling coefficient at considerable distances. Our designed PA with a drain efficiency of 77.8% for a maximum output of 5W is used with adopted tuning technique that improves the overall WPT system performance by 3 dB at various operating points.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power trajectory in Complex plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 탁소전력의 궤적변화)

  • Kwon, O.S.;Kim, C.H.;Park, N.O.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.310-312
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load the oscillation can be severe and even increase largely and finally the out-of-step condition may occur During the power swing and out-of-step conditions, the a apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

  • PDF

A Study on the Optimal Routing Technique for the Improvement of Voltage Stability in Radial Power System (방사상 전력계통의 전압안정도 향상을 위한 최적 라우팅 기법에 관한 연구)

  • Kim, Byung-Seop;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.11
    • /
    • pp.568-576
    • /
    • 2002
  • This paper presents a new algorithm for the enhancement of voltage stability by optimal routing (OR) technique. A new voltage stability index (VSI) for optimal routing is also proposed by using theories of critical transmission path based on voltage phasor approach and equivalent impedance method. Furthermore, the proposed algorithm automatically detect the critical transmission path to critical transmission path to critical load which are faced to voltage collapse due to additional real or reactive loading. We also adopt a improved branch exchange (IBE) algorithm based on a tie branch power (TBP) flow equation to apply the OR technique. The proposed IBE algorithm for the VSI maximizing can effectively search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been evaluated with the practical IEEE 32, 69 bus test systems and KEPCO 148 bus test system to show favorable performance.

A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC) (전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구)

  • Kim, Yong-Tae;Shin, Kwan-Woo;Lee, Youn-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

A Study on the Voltage Stability Enhancement in Radial Power System (방사상 전력계통의 전압안정도 향상에 관한 연구)

  • Kim, Byung-Seop;Jeong, Yun-Won;Park, Jong-Bae;Shin, Joong-Rin;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.87-89
    • /
    • 2002
  • This paper presents a new approach using an Improved branch exchange (IBE) technique to maximize the voltage stability as well as loss minimization in radial power systems. A suitable voltage stability index (VSI) for optimal routing algorithm is developed using novel methods both a critical transmission path based on a voltage phasor approach and an equivalent impedance method. Furthermore, the proposed algorithm can automatically detect the critical transmission path to be reached to a critical load faced with voltage collapse due to additional real or reactive leading. To develop an effective optimization technique, we also have applied a branch exchange algorithm based on a newly derived index of loss change. The proposed IBE algorithm for VSI maximization can effectively search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been tested with the various radial power systems to show its favorable performance.

  • PDF

The Study on Correction of Protective Relaying Set Value for the Power Electric Network Paralleled with Wind Farm (풍력전단지의 계통 연계 운전에 따른 보호 계전기 설정치 정정에 관한 고찰)

  • Jang, Sung-Il;Choi, Don-Man;Choi, Jeong-Hwan;Kim, Kwang-Ho;Oh, Jong-Youl;Kim, Joo-Yearl
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.487-490
    • /
    • 2002
  • Wind farm paralleled with electric power network can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the power line with wind farm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator. Consequently, it is difficult to detect the fault happened in the distribution network connected with wind generator. This paper describes the influence of wind turbine generator on the protective relaying system for detecting the fault occurred in a power line network. Simulation results shows that the fault current depends on the fault impedance, location, and the capacity of wind farm and distribution network load.

  • PDF

Debonding monitoring of CFRP strengthened RC beams using active sensing and infrared imaging

  • Sohn, Hoon;Kim, Seung Dae;In, Chi Won;Cronin, Kelly E.;Harries, Kent
    • Smart Structures and Systems
    • /
    • v.4 no.4
    • /
    • pp.391-406
    • /
    • 2008
  • This study attempts to develop a real-time debonding monitoring system for carbon fiber-reinforced polymer (CFRP) strengthened structures by continuously inspecting the bonding condition between the CFRP layer and the host structure. The uniqueness of this study is in developing a new concept and theoretical framework of nondestructive testing (NDT), in which debonding is detected without relying on previously-obtained baseline data. The proposed reference-free damage diagnosis is achieved based on the concept of time reversal acoustics (TRA). In TRA, an input signal at an excitation point can be reconstructed if the response signal measured at another point is reemitted to the original excitation point after being reversed in the time domain. Examining the deviation of the reconstructed signal from the known initial input signal allows instantaneous identification of damage without requiring a baseline signal representing the undamaged state for comparison. The concept of TRA has been extended to guided wave propagations within the CFRP-strengthened reinforced concrete (RC) beams to improve the detectibility of local debonding. Monotonic and fatigue load tests of large-scale CFRP-strengthened RC beams are conducted to demonstrate the potential of the proposed reference-free debonding monitoring system. Comparisons with an electro-mechanical impedance method and an inferred imaging technique are provided as well.

Human-Robot Cooperative Control for Construction Robot (건설로봇용 인간-로봇 협업 제어)

  • Lee, Seung-Yeol;Lee, Kye-Young;Lee, Sang-Heon;Han, Chang-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.285-294
    • /
    • 2007
  • Previously, ASCI(Automation System for Curtain-wall Installation) which combined with a multi-DOF manipulator to a mini-excavator was developed and applied on construction site. As result, the operation by one operator and more intuitive operation method are proposed to improve ASCI's operation method which need one person with a remote joystick and another operating an excavator. The human-robot cooperative system can cope with various and untypical constructing environment through the real-time interacting with a human, robot and constructing environment simultaneously. The physical power of a robot system helps a human to handle heavy construction materials with relatively scaled-down load. Also, a human can feel and response the force reflected from robot end effecter acting with working environment. This paper presents the feasibility study regarding the application of the proposed human-robot cooperation control for construction robot through experiments on a 2DOF manipulator.

A Stduy on the Signal Anti-reduction Equipment in Power Line Communication (전력선 통신 시스템을 위한 신호 감쇠 저하 장치 연구)

  • 고종선;김주환;윤성구;이기원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.370-376
    • /
    • 2000
  • In this paper, a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tele-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage and increasing carrier current. Proposed idea is a special type switching amplifier system which has a low inner resistance. It can provide reactive power and does not have low impedance between the transceivers. This new system is proposed to overcome the loss of conductor load in a PLC system.

  • PDF