• 제목/요약/키워드: load distribution factor

검색결과 411건 처리시간 0.025초

새로운 선로사고분배계수 알고리즘을 이용한 과부하 해소대책 (An Overload Alleviation Countermeasure using New Line Outage Distribution Factor)

  • 박규홍;정재길;강동구;김정하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.588-590
    • /
    • 1995
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads in a power system. This method utilizes network sensitivity factors which are establised from DC load flow solutions. The line outage distribution factors(LODF) are formulated using changes in network power generations to simulate the outaged line from the network. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

선로사고분배계수를 이용한 상정사고 선택 (Contingency Ranking Using A Line Outage Distribution Factor)

  • 박규흥;유헌재;정재길;강영묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.760-763
    • /
    • 1996
  • This paper presents an algorithm for the contingency ranking in a power system. The method utilizes line outage distribution factors(LODF) which are established from DC load flow solutions. The LODF are formulated using changes in network power generations to simulate the outaged line from the network. To abtain better ranking. one can take a line loading of 60% over into account in the computation of PI. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

45kVA UPQC 제어 알고리즘 설계 (A Control Algorithm Design for 45kVA UPQC Prototype)

  • 전진홍;김태진;류홍제;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1483-1485
    • /
    • 2005
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality problems. As a series and shunt compensator, UPQC consists of two inverters with common dc link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present simulation and test result of developed UPQC system. Test for UPQC are performed at voltage sag, flickers and non-linear load conditions. For voltage sag and ficker generation, we use RTDS(Real Time Digital Simulator) and power amplifier system.

  • PDF

단위역률 정류기의 병렬운전 (Parallel operation of rectifier with unit-power factor)

  • 이성희;김태원;박재욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1212-1213
    • /
    • 2011
  • PWM(pulse width modulation) rectifier has unit power factor and low harmonic distortion with high power conversion efficiency in entire loading range. These merits of PWM rectifier help the spread of DC distribution system. In addition, if multiple PWM rectifiers can be operated in parallel connection, maintenance process can be simple and reliability of power source can be advanced because of the hot swapping is available. The other way, the load unbalance among rectifiers can force a converter to stop by over current. The surge current by closed circuit composition between rectifiers can force switching devices damage. In this paper, some problems that can occur in case of parallel operation of PWM rectifiers and problem eliminating methods are considered.

  • PDF

강우자료 분석에 의한 소수력 발전소의 성능예측 (Performance Prediction of Small Hydropower Plant through Analyzing Rainfall Data)

  • 이철형;박완순;신동렬;정헌생
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.81-91
    • /
    • 1989
  • This study represents the method to predict the flow duration curve and primary design specifications of small hydropower plant at hydropower site through analyzing the monthly rainfall data. Weibull distribution was selected to characterize the rainfall data and Thiessen method was used to calculate monthly average flowrate at site. Application of these results, primary design specifications such as design flowrate, annual average load factor and utility factor, annual average hydropower density and annual electric energy production were estimated and discussed for surveyed site located in Daigi-ri, Kangwon province. And performance characteristic model of small hydro-power plant was applied to estimate these specifications.

  • PDF

실측에 의한 특고압수용가의 전력품질 분석 (Analysis of Power Quality for Extra-High Voltage Customers by Field Tests)

  • 지평식;문종필
    • 전기학회논문지P
    • /
    • 제61권2호
    • /
    • pp.82-86
    • /
    • 2012
  • Recently, due to the expansion of electric power demands, nonlinear load such as converters and inverters connected to the electric power distribution system, and extensive application of harmonic generation sources with power electric devices, disturbance of the electric power system and its influences on industries have been continuously increasing. In this research, power quality was analyzed for 11 extra-high voltage customers by considering voltage unbalance condition, power factor, THD and TDD. This research will be utilized as fundamental data to improve power quality for power utility.

5톤 송풍기용 FAN 인양기 구조설계 (Structural Design of CN fan Lift of 5 tonne Fans for Air Conditioner)

  • 이형욱;이광희
    • 융복합기술연구소 논문집
    • /
    • 제9권1호
    • /
    • pp.25-30
    • /
    • 2019
  • Normal cranes cannot be used to move the fan inside the high-rise factories. Due to the size of the fan and safety accidents, there is a need for a structure capable of lifting and transporting. In this study, the safety of the structure was evaluated by considering the center of gravity of the fan and the effect of the fan being tilted up. An analysis of the buckling was performed by hand calculation. Nonlinear analysis was performed using ABAQUS to evaluate the safety of the structure. The safety factor for buckling is above 4.0 and the safety factor for stress is calculated to be 1.31 under the worst load distribution conditions.

An Optimal Procedure for Sizing and Siting of DGs and Smart Meters in Active Distribution Networks Considering Loss Reduction

  • Sattarpour, T.;Nazarpour, D.;Golshannavaz, S.;Siano, P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.804-811
    • /
    • 2015
  • The presence of responsive loads in the promising active distribution networks (ADNs) would definitely affect the power system problems such as distributed generations (DGs) studies. Hence, an optimal procedure is proposed herein which takes into account the simultaneous placement of DGs and smart meters (SMs) in ADNs. SMs are taken into consideration for the sake of successful implementing of demand response programs (DRPs) such as direct load control (DLC) with end-side consumers. Seeking to power loss minimization, the optimization procedure is tackled with genetic algorithm (GA) and tested thoroughly on 69-bus distribution test system. Different scenarios including variations in the number of DG units, adaptive power factor (APF) mode for DGs to support reactive power, and individual or simultaneous placing of DGs and SMs have been established and interrogated in depth. The obtained results certify the considerable effect of DRPs and APF mode in determining the optimal size and site of DGs to be connected in ADN resulting to the lowest value of power losses as well.

Searching for critical failure surface in slope stability analysis by using hybrid genetic algorithm

  • Li, Shouju;Shangguan, Zichang;Duan, Hongxia;Liu, Yingxi;Luan, Maotian
    • Geomechanics and Engineering
    • /
    • 제1권1호
    • /
    • pp.85-96
    • /
    • 2009
  • The radius and coordinate of sliding circle are taken as searching variables in slope stability analysis. Genetic algorithm is applied for searching for critical factor of safety. In order to search for critical factor of safety in slope stability analysis efficiently and in a robust manner, some improvements for simple genetic algorithm are proposed. Taking the advantages of efficiency of neighbor-search of the simulated annealing and the robustness of genetic algorithm, a hybrid optimization method is presented. The numerical computation shows that the procedure can determine the minimal factor of safety and be applied to slopes with any geometry, layering, pore pressure and external load distribution. The comparisons demonstrate that the genetic algorithm provides a same solution when compared with elasto-plastic finite element program.

유한요소법을 이용한 교합 하중 위치에 따른 임플란트 지지골의 응력분포 비교분석 (A Comparative Analysis of Stress Distribution in the Implant Supporting Bone by Occlusal Loading location Utilizing the Finite Element Method)

  • 이명곤;김영직;김치영
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.105-113
    • /
    • 2005
  • The purpose of this study is to evaluate the effect of loading at three different occlusal surface position of the gold alloy crown on the stress distributions in surrounding bone, utilizing 3-dimensional finite element method. A three dimensional finite element model of an implant with simplified gold alloy crown and supporting bone was developed for this study. A oblique or vertical load of 100 N was applied at the following position at each FE model : 1) center of occlusal surface, 2) a point on the buccal side away from center of occlusal surface (COS) by 2.8mm, 3) a point on the lingual side away from COS by 2.8mm. In the results, Minimum von Mises stresses under vertical load or oblique load of 100N were about 6MPa at the center of occlusal surface and about 40MPa at the point on the buccal side, respectively. From the results we could come to the conclusion that occlusive loading position could be an important factor for establishment of structural safety of supporting bone.

  • PDF