• 제목/요약/키워드: living noise

검색결과 290건 처리시간 0.026초

실 충격원에 대한 바닥마감재 성능 분석 (Performance of floor coverings by impact sound)

  • 정진연;임정빈;이성찬;김경우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.419-422
    • /
    • 2014
  • Floor impact sound level is affected by various factors. This study was examined about impact sources and floor coverings influenced at floor impact sound. So this study wishes to get method to reduce sound pressure level of receiving room. Light-weight impact sound in mid frequency and Heavy-weight impact sound in low frequency was affected by floor coverings. Therefore, method to reduce floor impact sound level is to use proper floor coverings. Some coverings can amplify the heavy-weight impact sound in low frequency. Floor impact sound sources used measurement and analysis were standard heavy-impact source(Tapping, Bang, Ball) and living impact sources(Cleaner, Chair, Toy-car, Soccer ball). And Floor coverings used measurements were various thickness vinyl, laminate(or ply-wood) floor. Especially vinyl floor coverings were very effective method to reduce floor impact.

  • PDF

공동주택 수음실의 평면형태에 따른 중량충격음 특성 변화 연구 (A Study on the Heavy Impact Sound Insulation Performance of Apartments depending on the Shape of Receiving Room)

  • 기노갑;김항;최은석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1317-1320
    • /
    • 2006
  • This study compared the floor impact sound level of rectangular receiving room type to differed receiving room types to analyze effect of room mode. The floor impact sound level of master room were higher than the level of living room which resulted from room mode. The result showed that the level of low frequency bandwidth in the location varied with receiving room types were lower than general measuring point of rectangular receiving room.

  • PDF

일본에 있어서의 공해의 역사와 환경 계획증명사업의 현황에 대하여 (A Brief histor of Pollution and the Present Situation of the environment measuring Certifiers in Japan)

  • Shinobu-Miyagine
    • 한국기술사회:학술대회논문집
    • /
    • 한국기술사회 1983년도 한일기술사 합동 심포지움
    • /
    • pp.74-77
    • /
    • 1983
  • To attain the rich and comfortable human living, much development and economic growth are needed. But the radical development destroys natural environments or resources, and also the life environments are destroyed. How to maintain the balance between development and environments forms an important problem. Since 1955, a great deal of damage has been done to human being by the pollution of air, water or noise in Japan, for example, Minamata-byo (1956), arsenical poisoning by mkil (1955), Cd-I taiitai-byo (1955), asthma by air pollution, etc. Now, there are over 100,000 sick persons suffering from pollution in Japan. To prevent the pollution, the first act was made 1967, the kind of which were defined as follow:air, water, soil, noise, vibration ground subsidence, and bad smell. Laws on these were established 1970∼1981, and the environments here ave gradually being improved. The mentioned above gituation necsesitates the measuring or chemical analysis of pollution data, but the many cost is necessary to obtain such data. The special environment measuring certifier was needed and the Measurement Law was amended 1974. Some comment will be given of the present condition of environmental measuring certifier.

공동주택의 바닥충격진동 저감을 위한 유한요소법 및 다구찌법의 활용 (Application of Finite Element Method and Taguchi Method to Reduce Floor Impact Vibration in Apartment Buildings)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.385-388
    • /
    • 2005
  • Finite element method and Taguchi method were used to reduce the floor impact vibration of the reinforced concrete slab in the apartment buildings. At first, experimental results show that sound peak components to influence the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab, and there is a high linear relation between floor impact vibration and sound. The tables of orthogonal arrays were used for finite element analysis with 5 factors related to slab shape parameters and its results were analyzed by statistical method. The most effective factor to reduce the floor impact vibration was the length of living/kitchen room and the floor impact vibration was predicted by 30% reduction in the acceleration peak by the optimal design values of the factors.

  • PDF

건축물(建築物) Elevator Cage의 진동(振動) 측정(測定) (The Vibration measurement which occurs from the Elevator Cage of the Building)

  • 전의식;조병후
    • 한국디지털건축인테리어학회논문집
    • /
    • 제4권2호
    • /
    • pp.52-59
    • /
    • 2004
  • The interest about noise and vibration which occurs in buildings is increasing by a living level elevation recently. Particularly, the vibration which occurs from the elevator cage of the building is possibility of damage to the users of the building continuously. So, the purpose of this study is to suggest of measuring results to the vibration that occurs from the elevator cage and propose the countermeasure of it.

  • PDF

건축물(建築物) Elevator의 방진(防振)을 위한 진동특성(振動特性) 분석(分析) (The vibration quality analysis for the vibration prevention of the building elevator)

  • 전의식;조병후
    • 한국디지털건축인테리어학회논문집
    • /
    • 제5권2호
    • /
    • pp.29-35
    • /
    • 2005
  • The interest about noise and vibration which occurs in buildings is increasing by a living level elevation recently. Particularly, the vibration which occurs from the elevator cage of the building is possibility of damage to the users of the building continuously. So, the purpose of this study is a place where it examines closely the vibrating unit of the elevator and propose the countermeasure of it.

  • PDF

서울지하철 7-20공구 터널 굴착으로 인한 지상 주택 구조물에 미치는 진동 소음 영향 조사연구 (On The influence study to building by seoul sub-way construction 7-20 site Tunnel works.)

  • 허진
    • 화약ㆍ발파
    • /
    • 제13권3호
    • /
    • pp.7-18
    • /
    • 1995
  • On the Seoul sub-way tunnel works 7-20 site, Cautious blasting works were so effectivelly carried out. The vibration record were under 0.3cm/sec and blasting noise was under 80dB. Which was measured at the ground of house. At a result cautious blasting works under above allowable value was not influenced the structure of house and living conditions. On the architectural survey, They were some hair crack on the wall and floors but this was not a crack from blasting works.

  • PDF

서울지하철공사 8-6공구터널 발파작업으로 인한 진동, 소음이 지상주택가 구조물에 미치는 연구조사 (On the Influence Study to Building by Seoul Sub-way(8-6 site) Tunnel works)

  • 허진;전상백
    • 화약ㆍ발파
    • /
    • 제12권1호
    • /
    • pp.5-31
    • /
    • 1994
  • On the Seoul Sub-way Tunnel works (8-6 site ). Cautious blasting works were so effectivelly tarried out the vibration record were under 0.3cm /sec and blasting noise was under 75dB which was measured at the ground of house. As a result cautious blasting works under above allowable value was not influenced the structure of house and living. On the architectural survey, There were some hair crack on the wall and floors but this was not a crack from balsting work.

  • PDF

지하공간의 환경 및 안전관리 요소 (The Factors Governing Envlronment and Safety in Underground Spaces)

  • 김복윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 지하공간 건설기술에 관한 서울 심포지움 논문집
    • /
    • pp.133-162
    • /
    • 1993
  • The environment of underground spaces might be considered in view of working environment during the construction and living environment after completion of the construction work. For controlling environment of underground space, an appropriate measures have to be taken on the governing factors such as air flow, dust, gases, heat, radiation, noise, illumination and water. The more critical matter, in underground environmental point of view, is underground disasters such as fire, gas explosion and water inrush. This paper presents the general introduction of these factors mentioned above and some outcomes of research works as of now.

  • PDF

통신구 터널발파작업으로 인한 진동.소음이 지상주택에 미치는 영향 평가 (On the influence survey to building by the cable Tunnel blasting works.)

  • 허진;김상백
    • 화약ㆍ발파
    • /
    • 제11권1호
    • /
    • pp.5-33
    • /
    • 1993
  • On the cable Tunnel works. Cautious blasting works were so effective and carried out. The vibration record were under 0.4cm / sec and blasting noise are under 75dB Which it was measured at the ground of Tailor House. As a result cautious blasting works under above allowable value, are not Influenced the structure of house and living. On the architechtural survey, there were some hair crack on the wall but this was not crack from recently blasting work.

  • PDF