• Title/Summary/Keyword: liver volume

Search Result 286, Processing Time 0.024 seconds

Pharmacokinetics of LB20304, a New Fluoroquinolone, in Rats and Dogs

  • Seo, Mi-Kyeong;Lee, Sun-Hwa;Choi, Yun-Jeong;Jeong, Yi-Na;Lee, Sung-Hack;Kim, In-Chull;Lee, Yong-Hee
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.359-367
    • /
    • 1996
  • The pharmacokinetics of LB20304 was investigated following intravenous (IV) and oral administration to rats and dogs. Additionally, in vitro metabolism and serum protein binding studies were also conducted. The total body clearance, apparent volume of distribution, terminal half-life, and extent of bioavailability were 21.8 ml/min/kg, 2265 ml/kg, 93.6 min, and 30.8% for rats; and 7.95 ml/min/kg, 4144 ml/kg, 363 min, and 81.1% for dogs, respectively. LB20304 was stable in the liver microsome containing NADPH generating system and its serum protein binding was 58.5-65.8% for rats, 19.1-29.6% for dogs, and 56.9-59.6% for humans. Its tissue concentration levels in lever, stomach, small intestine, and kidney were 9.5 to 26.1 times greater than plasma level, but the concentration in testis was quite low and that in brain was negligible in rats. The 48 hr urinary recovery of the dose was 44% for IV dosing and 14% for oral dosing, shereas the 48 hr biliary recovery of the dose was 6.4% for IV dosing and 4.5% for oral dosing in rats. In summary, the pharmacokinetic properties of LB20304 were characterized by its good oral absorption, long plasma half-life, and good tissue distribution.

  • PDF

Anti-obesity effects of Tenebrio molitor larvae powder in high-fat diet-induced obese mice

  • Park, Bo Mi;Lim, Hyung Ju;Lee, Bong Joo
    • Journal of Nutrition and Health
    • /
    • v.54 no.4
    • /
    • pp.342-354
    • /
    • 2021
  • Purpose: Obesity is a serious public health issue for the modern society and is considered a chronic health hazard. There are many surgical and pharmacological approaches to treat obesity. However, various potentially hazardous side effects remain the biggest challenge. Therefore, diets based on foods derived from natural products have gained increasing attention compared to anti-obesity drugs. Recently, research on edible insects as a food source has been a topic of considerable interest in the scientific communities. This study examined the anti-obesity effects of ingesting an edible insect by feeding a high-fat diet (HFD)-induced obese mouse models with a diet containing Tenebrio molitor larvae powder (TMLP). Methods: Six-week-old female C57BL/6J mice were divided into 4 groups according to treatment: 100% normal diet (ND), 100% HFD (HFD), HFD 99% + TMLP 1% (TMLP), and HFD 97% + TMLP 3% (TMLP 3%). TMLP was added to the HFD for 6 weeks for the latter two groups. Results: Compared to the HFD group, mice in the TMLP group showed weight loss, and micro-computed tomographic imaging revealed that the volume of the adipose tissue in the abdominal area also showed significant reduction. After an autopsy, the fat weight was found to be significantly reduced in the TMLP group compared to the HFD group. In addition, the degree of fat cell deposition in the liver tissue and the size of the adipocytes significantly decreased in the TMLP group. Reverse transcription polymerase chain reaction analysis for the mRNA expression of adipogenesis-related genes namely CCAAT-enhancer-binding proteins (C/EBP-β, C/EBP-δ), and fatty acid-binding protein 4 (FABP4) showed that the expression levels of these genes were significantly reduced in the TMLP group compared to the HFD group. Serum leptin level also decreased significantly in the TMLP group in the comparison with the HFD group. In addition, total cholesterol, triglyceride, and glucose levels in mouse serum also decreased in the TMLP group. Conclusion: Taken together, our results showed that TMLP effectively inhibited adipocyte growth and reduced body weight in obese mice.

Assessment of Abdominal Organs Movement by Respiration Using Computed Tomography in Dogs: A Pitfall for Radiation Therapy

  • Ah Reum Kim;Soyon An;Gunha Hwang;Moonyeong Choi;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.104-112
    • /
    • 2023
  • The change in the position of the abdominal organs due to movement by respiration is one of the reasons behind inaccurate irradiation of organs during radiotherapy (RT). Although studies in human medicine have revealed on the respiratory movements of abdominal organs, there is little information and no reference data for dogs. The purpose of this study was to establish the reference values of abdominal organs movement in various postures using computed tomography (CT), and to compare the movements of organs between dorsal recumbency and ventral, right and left lateral recumbency during respiration. CT images for kidney, adrenal gland, medial iliac lymph node, urinary bladder, gallbladder, liver, stomach, and thoracic and lumbar vertebral body of five beagle dogs were acquired. The movements of organs were evaluated by comparing the end-expiratory and end-inspiratory images. Movements of the organs were evaluated by dividing it into right-to-left, dorsal-to-ventral, and cranial-to-caudal directions. The movements of abdominal organs according to the change in postures and respiration were establish. The movement of the bilateral organs was the least when the organs were in the downward position (p < 0.017). The movement of cranial-to-caudal direction was greater than the movement of the other directions in most of the organs. Data obtained in this study may be useful in selecting the appropriate posture that can reduce the movements of organs to be treated with RT, and the data could be useful for setting the planning target volume to consider the movements of the abdominal organs by respiration.

Ablative Outcomes of Various Energy Modes for No-Touch and Peripheral Tumor-Puncturing Radiofrequency Ablation: An Ex Vivo Simulation Study

  • Dong Ik Cha;Min Woo Lee;Kyoung Doo Song;Seong Eun Ko;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.189-201
    • /
    • 2022
  • Objective: To compare the outcomes of radiofrequency ablation (RFA) using dual switching monopolar (DSM), switching bipolar (SB), and combined DSM + SB modes at two different interelectrode distances (25 and 20 mm) in an ex vivo study, which simulated ablation of a 2.5-cm virtual hepatic tumor. Materials and Methods: A total of 132 ablation zones were created (22 ablation zones for each protocol) using three separable clustered electrodes. The performances of the DSM, SB, and combined DSM + SB ablation modes were compared by evaluating the following parameters of the RFA zones at two interelectrode distances: shape (circularity), size (diameter and volume), peritumoral ablative margins, and percentages of the white zone at the midpoint of the two electrodes (ablative margin at midpoint, AMm) and in the electrode path (ablative margin at electrode path, AMe). Results: At both distances, circularity was the highest in the SB mode, followed by the DSM + SB mode, and was the lowest in the DSM mode. The circularity of the ablation zone showed a significant difference among the three energy groups (p < 0.001 and p = 0.002 for 25-mm and 20-mm, respectively). All size measurements, AMm, and AMe were the greatest in the DSM mode, followed by the DSM + SB mode, and the lowest were with the SB mode (all statistically significant). The white zone proportion in AMm and AMe were the greatest in the SB mode, followed by the DSM + SB mode and DSM in general. Conclusion: DSM and SB appear to be complementary in creating an ideal ablation zone. RFA with the SB mode can efficiently eradicate tumors and create a circular ablation zone, while DSM is required to create a sufficient ablative margin and a large ablation zone.

Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy (호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가)

  • Cho, Yoon-Jin;Jeon, Mi-Jin;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Sook;Im, Jung-Ho;Lee, Ik-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: It is essential to minimize the respiratory-induced motion of involved organs in the Tomotherapy for tumor located in the chest and abdominal region. However, the application of breathing control system to Tomotherapy is limited. This study was aimed to investigate the possible application of the ABCHES system and its efficacy as a means of breathing control in the tomotherapy treatment. Materials and Methods: Five subjects who were treated with a Hi-Art Tomotherapy system for lung, liver, gallbladder and pancreatic tumors. All patients undertook trained on two breathing methodes using an ABCHES, free breathing methode and shallow breathing methode. When the patients could carry out the breathing control, 4D-CT scan was a total of 10 4D tomographic images were acquired. A radiologist resident manually drew the tumor region, including surrounding nomal organs, on each of CT images at the inhalation phase, the exhalation phase and the 40% phase (mid-inhalation) and average CT image. Those CT images were then exported to the Tomotherapy planning station. Data exported from the Tomotherapy planning station was analyzed to quantify characteristics of dose-volume histograms and motion of tumors. Organ motions under free breathing and shallow breathing were examined six directions, respectively. Radiation exposure to the surrounding organs were also measured and compared. Results: Organ motion is in the six directions with more than a 5 mm displacement. A total of 12 Organ motions occurred during free breathing while organ motions decreased to 2 times during shallow breathing under the use of Abches. Based on the quantitative analysis of the dose-volume histograms shallow breathing showed lower resulting values, compared to free breathing, in every measure. That is, treatment volume, the dose of radiation to the tumor and two surrounding normal organs (mean doses), the volume of healthy tissue exposed to radiation were lower at the shallow breathing state. Conclusion: This study proposes that the use of ABCHES is effective for the Tomotherapy treatment as it makes shortness of breathing easy for patients. Respiratory-induced tumor motion is minimized, and radiation exposure to surrounding normal tissues is also reduced as a result.

  • PDF

Study of overlapping setting up of Planning Target Volume for Improving Target Coverage adjacent Organ At Risk (손상위험장기에 인접한 표적 Coverage 개선을 위한 Planning Target Volume 중복 설정에 관한 연구)

  • Lee, Jung Woong;Kim, Bo Kyum;Mun, Jun Ki;Woo, Hun;Lee, Yang Hoon;Jeon, Chang Woo;Lee, Jea Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the reduction of coverage of PTVs adjacent to organ at risk (OAR) by setting up overlapping Planning Target Volume (PTV) during Volumetric Modulated Arc Therapy(VMAT). Materials and Methods: In patients who received Whole Brain, Gall Bladder and Rectum radiation therapy, We compared the cover change, maximum dose, Homogenicity Index and Conformity Index of PTV and also compared the maximum dose and average dose change of Organ At Risk by organizing treatment plans that are not applied overlaped PTV and treatment plans that are applied overlaped PTV in areas where coverage is insufficient. Results: overage of treatment plans with overlapping PTVs was increased in all patients, and overall coverage was also increased in each of the four patients. The maximum dose for PTV was increased in five patients, and the Homogenicity Index and Conformity Index for all patients did not differ much. The maximum dose of the lens was increased by 1.12 times, and the maximum dose was decreased in two patients for brain stem. The mean dose of the eyeball was increased by a maximum of 1.15 times, and there was no significant difference between both parotid gland. In case of gallbladder cancer patients, the mean dose in the liver and colon was decreased, and the mean dose in the duodenum was increased. In the case of rectal cancer patients, the mean dose was reduced for both femur and bladder set as OARs. The overall MU was shown to be similar in four patients, excluding one. Conclusion: If the critical dose of OAR is considered and used properly, I think it is a useful way to improve coverage of PTV.

Dosimetric Comparison of Intensity Modulated Radiation, Proton Beam Therapy and Proton Arc Therapy for Para-aortic Lymph Node Tumor (대동맥림프절 종양에 대한 세기조절방사선치료, 양성자치료, 양성자회전치료의 선량 비교평가)

  • Kim, JungHoon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.331-339
    • /
    • 2014
  • To test feasibility of proton arc therapy (PAT) in the treatment of para-aortic lymph node tumor and compare its dosimetric properties with advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT) and conventional 3D conformal proton beam therapy (PBT). The treatment plans for para-aortic lymph node tumor were planned for 9 patients treated at our institution using IMRT, PBT, and PAT. Feasibility test and dosimetric evaluation were based on comparisons of dose volume histograms (DVHs) which reveal mean dose, $D_{30%}$, $D_{60%}$, $D_{90%}$, $V_{30%}$, $V_{60%}$, $V_{90%}$, organ equivalent doses (OEDs), normal tissue complication probability (NTCP), homogeneity index (HI) and conformity index (CI). The average doses delivered by PAT to the liver, kidney, small bowel, duodenum, stomach were 7.6%, 3%, 17.3%, 26.7%, and 14.4%, of the prescription dose (PD), respectively, which is higher than the doses delivered by IMRT (0.4%, 7.2%, 14.2%, 15.9%, and 12.8%, respectively) and PBT (4.9%, 0.5%, 14.12%, 16.1% 9.9%, respectively). The average homogeneity index and conformity index of tumor using PAT were 12.1 and 1.21, respectively which were much better than IMRT (21.5 and 1.47, respectively) and comparable to PBT (13.1 and 1.23, respectively). The result shows that both NTCP and OED of PAT are generally lower than IMRT and PBT. This study demonstrates that PAT is better in target conformity and homogeneity than IMRT and PBT but worse than IMRT and PBT for most of dosimetric factor which indicate that PAT is not recommended for the treatment of para-aortic lymph node tumor.

Research for Lateral Penumbra and Dose Distribution When Air Gap Changing in Proton Therapy Case (양성자치료시 Air Gap 변화에 따른 Lateral Penumbra와 선량분포 변화에 대한 비교 및 연구)

  • Kim, Jae-Won;Sim, Jin-Seob;Jang, Yo-Jong;Kang, Dong-Yun;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • Purpose: In the treatment of high-energy protons Air gap (the distance between the patient and the exit Beam) Lateral Penumbra of the changes to the increase in the radiation fields can form unnecessary and Increase the maximum dose at the site of treatment and reduced the minimum dose homogeneity of dose distributions can decline. Air gap due to this change in dose distribution compared to investigate studied. Materials and Methods: Received proton therapy at our institution Lung, Liver patients were selected and the size of six other Air gap in Field A and Field B 2, 4, 6, 8, 10 cm Proton external beam planning system by setting up a treatment plan established. Air gap according to the Lateral Penumbra area and DVH (Dose Volume Histogram) to compare the maximum dose and minimum dose of PCTV areas were compared. In addition, the dose homogeneity within PCTV Homogeneity index to know the value and compared. Results: Air gap (2, 4, 6, 8, 10 cm) at each change in field size were analyzed according to the Lateral Penumbra region Field A Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 28.7% and Field B Change in the Air gap 2~10 cm by 1.36~1.75 cm, the average continuously increased about 31.6%. The result of DVH analysis for relative dose of the maximum dose According to Air gap 2~10 cm is the mean average of 110.3% from 108.1% to a sustained increased by approximately 2.03% and The average relative dose of minimum dose is the mean average of 93.9% percent to 90.8 percent from the continuous decrease of about 3.31 percent. The result of Homogeneity index value to the according to Air gap 2~10 cm is the 2-fold increase from 1.09 to 2.6. Conclusion: In proton therapy case, we can see the increasing of lateral penumbra area when airgap getting increase. And increasing of Dmax and decreasing Dmin in the field are making increase homogeneity index, So we can realize there are not so good homogeneity in the PCTV. Therefore we should try to minimize air gap in proton therapy case.

  • PDF

Effects of a Combined Diet of Jerusalem Artichoke's Inulin, Lotus Leaf and Herb Extracts in Obesity-induced White Rat with Fat Diet (돼지감자의 이눌린, 연잎, 허브의 병합식이가 고지방식이로 유도된 비만흰쥐에 미치는 영향)

  • Lee, Eun-Hye;Lee, Ye-Jin;Choi, Ok-Byung;Kang, Sang-Mo
    • Applied Biological Chemistry
    • /
    • v.50 no.4
    • /
    • pp.295-303
    • /
    • 2007
  • A preliminary diet experiment utilizing Jerusalem artichoke's inulin, lotus leaf powder, nettle powder and eucalyptus powder extract indicated that combining all four elements gave the most effective result. Therefore, a study was conducted to evaluate the effectiveness of combined diet for weight loss. In this study, Sprague-Dawley, male white rats about 200 g in weight was fed with high fat diet for 8 weeks in order to induce obesity followed by 4 week administration of combined diet to look into the effect of the diet. After a total of 12 weeks of feeding, factors relevant to weight, blood, and lipid metabolism by liver in the body were researched and histologic change was examined with optical microscope. In terms of weight change, both high fat diet group and regular diet group gained weight from high fat diet for 8 weeks compared to normal group. Then, for another 4 weeks, while normal group and high fat diet group kept gaining weight, combined diet group which was provided with high fat diet for 8 weeks, lost weight to the normal group level after 3 week administration of diet. However, after the 4th week of administration, the group weighted significantly less than the normal group and the efficiency of diet also significantly dropped. In the biochemical analysis of blood, total cholesterol, LDL-cholesterol, triglyceride, glucose, GOT, GPT, ${\gamma}-GTP$ and creatine showed significant increase in high fat diet group and there was no significant difference between diet group and normal group except for GPT, ${\gamma}-GTP$ and creatine. In the biochemical analysis of liver, there was significant increase in LDL-cholesterol, triglyceride of high fat diet group compared to normal group, while there was no significant difference in term of total cholesterol and HDL-cholesterol. Compared to normal group, diet group had higher HDL-cholesterol, while total cholesterol dropped significantly. There was no significant difference in terms of LDL-cholesterol and triglyceride. Besides, in high fat diet group, observation of histologic change in liver and change in ultrastructure showed volume increase of hepatic cell and severe fatty degeneration in hepatic cell around hepatic vein. However in diet group, like normal group, no pathological change was observed in terms of cytoplasm, nucleus and capillary in hepatocyte and the alignment of hepatocyte had regularity thanks to the administration of combined diet. Therefore, combined diet utilizing Jerusalem artichoke's inulin, lotus leaf powder, nettle powder and eucalyptus powder was proven to be an effective measure to prevent and improve obesity as a result of abnormal adipose deposition.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.