• Title/Summary/Keyword: liver segmentation

Search Result 48, Processing Time 0.024 seconds

Comparison of SUV for PET/MRI and PET/CT (인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화)

  • Kim, Jae Il;Jeon, Jae Hwan;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Artificial Intelligence based Tumor detection System using Computational Pathology

  • Naeem, Tayyaba;Qamar, Shamweel;Park, Peom
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Pathology is the motor that drives healthcare to understand diseases. The way pathologists diagnose diseases, which involves manual observation of images under a microscope has been used for the last 150 years, it's time to change. This paper is specifically based on tumor detection using deep learning techniques. Pathologist examine the specimen slides from the specific portion of body (e-g liver, breast, prostate region) and then examine it under the microscope to identify the effected cells among all the normal cells. This process is time consuming and not sufficiently accurate. So, there is a need of a system that can detect tumor automatically in less time. Solution to this problem is computational pathology: an approach to examine tissue data obtained through whole slide imaging using modern image analysis algorithms and to analyze clinically relevant information from these data. Artificial Intelligence models like machine learning and deep learning are used at the molecular levels to generate diagnostic inferences and predictions; and presents this clinically actionable knowledge to pathologist through dynamic and integrated reports. Which enables physicians, laboratory personnel, and other health care system to make the best possible medical decisions. I will discuss the techniques for the automated tumor detection system within the new discipline of computational pathology, which will be useful for the future practice of pathology and, more broadly, medical practice in general.

The Exquisite Automatic Segmentation of Liver and Spleen with Gray Value Portion (명암값 분포를 이용한 자동화된 간과 비장의 정교한 추출)

  • Yu, Seung-Hwa;Seong, Yun-Chang;Jo, Jun-Sik;No, Seung-Mu;Sin, Gyeong-Suk;Park, Jong-Won
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.28 no.1_2
    • /
    • pp.20-32
    • /
    • 2001
  • 각 장기는 고유한 명암값의 범위와 각 명암값에 대한 서로 다른 비율을 지니고 있으므로 제안된 연구에서는 이러한 명암값의 비율을 이용하여 장기의 영역과 노이즈를 구분할 수 있도록 하였다. 장기의 영역을 세 종류의 메쉬영상으로 표현하여 이들의 유니온 영상으로 장기의 전반적인 형태인 템플리트를 생성하였다. 템플리트 방식은 기존의 방식에서 명암값의 범위가 같은 노이즈의 제거가 어려운 단점을 해결하여 장기의 영역만을 분리할 수 있었다. 장기의 위치를 탐색하기 위한 위치탐색과정에서는 장기의 존재여부의 파악과 함께 분리된 장기까지 추적할 수 있도록 하였다. 외곽선 표현을 위해서는 템플리트로 이진영상에서 서브트랙션(subtraction)하는 방법을 사용하여 장기의 말단부위까지 세밀하게 표현하였다. 제안된 연구에서 사용된 오프닝과 클로징 방법으로 기존의 structuring element를 사용하는 방법에 비해 처리속도를 단축시킬 수 있었다. 추출된 장기의 면적을 토대로 체적계산을 시행하였고 동물실험을 통하여 임상 실험치를 제시하였다.

  • PDF

Auto-Segmentation Algorithm For Liver-Vessel From Abdominal MDCT Image Using Morphological Filtering (Morphological Filtering을 이용한 복부 MDCT 영상의 간혈관 자동 추출 알고리즘)

  • Park, Chun-Ja;Ryu, Gang-Min;Park, Jong-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.819-822
    • /
    • 2005
  • 본 연구는 MDCT 영상을 이용하여 인체의 장기인 간을 추출하고 그 간 내부의 혈관을 추출하는 알고리즘을 제안하였다. 간에는 2개의 주요혈관이 있는데 생체 간 이식 수술시 필수적인 간의 절개 비율 및 간 내의 혈관 모습들을 제공하여 의료진에게 수술 전 혈관 형태에 대한 정확히 정보를 파악하도록 함으로써 혈관의 손상을 최대한으로 줄일 수 있도록 하여 수술 성공률을 높이는데 중요한 역할을 할 수 있다. 간을 이식 할 때 기증자와 수혜자가 동시에 생존하기 위해서는 기증자의 간으 크기가 중요하며 둘다 생존하기 위해서는 기증자는 자신의 간의 35% 이상을 남겨야 하며 수혜자 또한 생존을 위해 자신의 간의 40% 이상에 해당하는 간을 이식 받아야 하는데 간 이식에 있어서 절단 부분을 결정하는데 중요한 중간 정맥을 찾아내어 보여 줌으로써 중간 정맥을 중심으로 3가닥의 굵은 혈관과 주변혈관의 손상을 최소화하고 비율을 잘 맞추어 절단 할 수 있도록 수술하는데 도움을 줄 수 있다. 각 혈관은 원형성과 다양한 각도를 갖는 막대형의 형태를 가지고 있다는 특징을 이용해 morphological filtering을 통해 추출한 후 조합하여 재구성을 하여 혈관의 모습으로 생성해 낼 수 있었다.

  • PDF

Parenchymal-sparing anatomical hepatectomy based on portal ramification of the right anterior section: A prospective multicenter experience with short-term outcomes

  • Truong Giang Nguyen;Thanh Khiem Nguyen;Ham Hoi Nguyen;Hong Son Trinh;Tuan Hiep Luong;Minh Trong Nguyen;Van Duy Le;Hai Dang Do;Kieu Hung Nguyen;Van Minh Do;Quang Huy Tran;Cuong Thinh Nguyen
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2024
  • Backgrounds/Aims: Parenchymal-sparing anatomical hepatectomy (Ps-AH) based on portal ramification of the right anterior section (RAS) is a new technique to avoid unnecessarily transecting too much liver parenchyma, especially in cases of major anatomical hepatectomy. Methods: We prospectively assessed 26 patients with primary hepatic malignancies having undergone major Ps-AH based on portal ramification of the RAS from August 2018 to August 2022 (48 months). The perioperative indications, clinical data, intra-operative index, pathological postoperative specimens, postoperative complications, and follow-up results were retrospectively evaluated. Results: Among the 26 patients analyzed, there was just one case that had intrahepatic cholangiocarcinoma The preoperative level of α-Fetoprotein was 25.2 ng/mL. All cases (100%) had Child-Pugh A liver function preoperatively. The ventral/dorsal RAS was preserved in 19 and 7 patients, respectively. The mean surgical margin was 6.2 mm. The mean surgical time was 228.5 minutes, while the mean blood loss was 255 mL. In pathology, 5 cases (19.2%) had microvascular invasion, and in the group of HCC patients, 92% of all cases had moderate or poor tumor differentiation. Six cases (23.1%) of postoperative complications were graded over III according to the Clavien-Dindo system, including in three patients resistant ascites or intra-abdominal abscess that required intervention. Conclusions: Parenchymal-sparing anatomical hepatectomy based on portal ramification of the RAS to achieve R0-resection was safe and effective, with favorable short-term outcomes. This technique can be used widely in clinical practice.

The Impact which An cultural environment along a social stratum has on Clothes taste and Sense of value Formation (사회계층에 따른 문화적 환경이 취향과 가치관 형성에 미치는 영향)

  • ;Akinori Ogimura
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.4 no.3
    • /
    • pp.89-95
    • /
    • 2002
  • Object of this study presents marketing of new market segmentation as what I classify a social stratum, and analyze sense of value about each social class clothes and a taste, but is. The study way used a questionnaire as an investigation study way, and I did execution from September to October in 1999, and the investigation object picked up an any table with the woman university student who lived in Seoul and did investigation, and analysis targeted total 550 people. I used a measurement item of economic capital and cultural capital as a classification item of a social stratum and selected a dwelling, a kind of property, an annual salary of parents as an index of economic capital. Presentation held an occupation of parents, scholarship, culture activity as an index of cultural capital. It is social stratum structure an occupation arranges in 12 job categories by, for your reference, I do a social orbit of the P. Bourdieu which is a French sociologist and an index of inheritance cultural capital, and having set up eight phases of evaluation, and to do a Y, Cultural Capital with X with economic capital. Sense of value about clothes and attitude selected social value, aesthetic appreciation enemy value, authority a few value in sense of value of the 6 type that E. Spranger(1922) presented, and a proposal did type in 3 about clothes. The measurement way used a 11 question item and measured I with five phases of Likert-type criteria and executed factors analysis by main ingredient analysis and varimax revolution law. I named a more than inherent 1 with the liver which was social man, aesthetic appreciation enemy man, an authority enemy with a basis. The results are as follows : People of the group which they belong to the same social class, and there is have a similar taste and select a similar product, and scholarship and an occupation of parents please lay a taste of children and sense of value, a hierarchical difference of attitude too and do it.

  • PDF

Three-dimensional Model Generation for Active Shape Model Algorithm (능동모양모델 알고리듬을 위한 삼차원 모델생성 기법)

  • Lim, Seong-Jae;Jeong, Yong-Yeon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.28-35
    • /
    • 2006
  • Statistical models of shape variability based on active shape models (ASMs) have been successfully utilized to perform segmentation and recognition tasks in two-dimensional (2D) images. Three-dimensional (3D) model-based approaches are more promising than 2D approaches since they can bring in more realistic shape constraints for recognizing and delineating the object boundary. For 3D model-based approaches, however, building the 3D shape model from a training set of segmented instances of an object is a major challenge and currently it remains an open problem in building the 3D shape model, one essential step is to generate a point distribution model (PDM). Corresponding landmarks must be selected in all1 training shapes for generating PDM, and manual determination of landmark correspondences is very time-consuming, tedious, and error-prone. In this paper, we propose a novel automatic method for generating 3D statistical shape models. Given a set of training 3D shapes, we generate a 3D model by 1) building the mean shape fro]n the distance transform of the training shapes, 2) utilizing a tetrahedron method for automatically selecting landmarks on the mean shape, and 3) subsequently propagating these landmarks to each training shape via a distance labeling method. In this paper, we investigate the accuracy and compactness of the 3D model for the human liver built from 50 segmented individual CT data sets. The proposed method is very general without such assumptions and can be applied to other data sets.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF