In vivo Evaluation of Flow Estimation Methods for 3D Color Doppler Imaging

  • Yoo, Yang-Mo
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.177-186
    • /
    • 2010
  • In 3D ultrasound color Doppler imaging (CDI), 8-16 pulse transmissions (ensembles) per each scanline are used for effective clutter rejection and flow estimation, but it yields a low volume acquisition rate. In this paper, we have evaluated three flow estimation methods: autoregression (AR), eigendecomposition (ED), and autocorrelation combined with adaptive clutter rejection (AC-ACR) for a small ensemble size (E=4). The performance of AR, ED and AC-ACR methods was compared using 2D and 3D in vivo data acquired under different clutter conditions (common carotid artery, kidney and liver). To evaluate the effectiveness of three methods, receiver operating characteristic (ROC) curves were generated. For 2D kidney in vivo data, the AC-ACR method outperforms the AR and ED methods in terms of the area under the ROC curve (AUC) (0.852 vs. 0.793 and 0.813, respectively). Similarly, the AC-ACR method shows higher AUC values for 2D liver in vivo data compared to the AR and ED methods (0.855 vs. 0.807 and 0.823, respectively). For the common carotid artery data, the AR provides higher AUC values, but it suffers from biased estimates. For 3D in vivo data acquired from a kidney transplant patient, the AC-ACR with E=4 provides an AUC value of 0.799. These in vivo experiment results indicate that the AC-ACR method can provide more robust flow estimates compared to the AR and ED methods with a small ensemble size.

Concurrent Patent Ductus Arteriosus and Congenital Extrahepatic Portosystemic Shunt with Suspected Portal Vein Aplasia in a Dog

  • Chae, Soo-young;Cho, Yu-gyeong;Lee, Young-won;Choi, Ho-jung
    • 한국임상수의학회지
    • /
    • 제34권4호
    • /
    • pp.283-286
    • /
    • 2017
  • A 4-month-old, female Maltese dog was referred with continuous heart murmur. Patent ductus arteriosus was diagnosed via radiography and echocardiography. The patient was untreated because of client's refusal. After 13 months, the dog was referred again with seizure and salivation. Laboratory examination revealed increased liver enzymes, hyperammonemia and decreased total cholesterol and total protein. Microhepatica was identified on abdominal radiography. CT angiography showed a shunt vessel that originated from the portal trunk to the prehepatic caudal vena cava and patent ductus arteriosus connecting proximal descending aorta with the main pulmonary artery. No portal vasculature toward liver is observed after shunt vessel. The patient was diagnosed as concurrent patent ductus arteriosus and congenital extrahepatic portosystemic shunt with suspected portal vein aplasia. In human, cardiac malformations are frequently observed in patients with congenital extrahepatic portosystemic shunt with portal vein aplasia. This report described concurrent patent ductus arteriosus and congenital extrahepatic portosystemic shunt with suspected portal vein aplasia in a dog.

Concurrent Torsion of the Caudate Liver Lobe and Spleen in a German Shepherd Dog

  • Seong-won An;Seung-Min Hwang;Il-Gwon Jung;Sang-Kwon Lee;Young-Sam Kwon
    • 한국임상수의학회지
    • /
    • 제41권1호
    • /
    • pp.30-36
    • /
    • 2024
  • A 3-year-old, 20.6 kg, neutered male German Shepherd dog was referred to Kyungpook National University Veterinary Medicine Teaching Hospital. Clinical examination revealed chronic diarrhea for 6 weeks and a non-tender, distended abdomen without lethargy, anorexia, and vomiting. Diarrhea was watery and had a waxing and waning course despite symptomatic treatment. A complete blood count identified mild leukocytosis and mild anemia. Serum biochemistry analysis showed elevated alanine aminotransferase and aspartate aminotransferase levels, and mild hypoalbuminemia. Abdominal ultrasound examination revealed mixed echogenicity with absent blood flow at the caudate process of the caudate liver lobe and a small amount of ascites. Computed tomography revealed torsion of the caudate process of the caudate liver lobe and spleen and gas dilatation of the intestine. After establishing a diagnosis of organ torsion on imaging, we deemed the condition an emergency and immediately performed surgery. Given that laparotomy confirmed organ torsion, liver lobectomy, total splenectomy, and prophylactic gastropexy were conducted. The patient was discharged 11 days after surgery without complications. In general, liver lobe torsion and splenic torsion are uncommon in dogs and present with nonspecific clinical signs, such as abdominal pain, lethargy, anorexia, and vomiting. In the current case, torsion of the caudate liver lobe and spleen occurred without other clinical signs except for a distended abdomen. Moreover, no reports in dogs have demonstrated the simultaneous occurrence of both diseases.

Splenic Absorption of Radiopharmaceutical in Systemic Bone Scans Performed after Liver Transplantation

  • Sang-Hyeong Kil;Kyung-Nam Jo;Yung-Hyun Lim
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.4-6
    • /
    • 2023
  • Technetium-labeled phosphate bone scan was shown to detect bone fractures and bone metastasis in early stage than general radiographs. Therefore, bone scan has become one of the most frequently performed nuclear medicine imaging examination. However, non-osseous radiopharmaceutical uptake on the bone scan are unusual findings. We report a case of diffuse splenic absorption of Tc-99m dicarboxypropane diphosphonate in patients who undergo liver transplantation.

  • PDF

$^{18}F-FDG$ PET/CT 에서 발견된 S상 결장암의 단일 비장 전이 (Isolated Splenic Metastasis of Sigmoid Colon Cancer Detected by $^{18}F-FDG$ PET/CT)

  • 안영실;윤준기;홍선표;최봉회;조철우;윤석남
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.263-264
    • /
    • 2007
  • Splenic metastasis from colon carcinoma are rare and usually occur in the presence of disseminated visceral metastasis. The liver is the most common site of metastatic spread from colon cancer. Several hypotheses have attempted to explain the low incidence of splenic metastasis. It should be difficult for colorectal cancer cells to reach the spleen through the portal venous system, in which the blood flow is usually from the spleen to the liver. Reticuloendothelial system or rhythmic contraction of the spleen may squeeze out the tumor in the spleen. The absence of afferent lymphatic to the spleen, phagocytic activity and humoral anticancer substances are considered to be other reason for low incidence of splenic metastasis. We report the case of $^{18}F-FDG$ PET/CT finding in a 70-year-old woman who develop isolated splenic metastasis of sigmoid colon cancer.

고주파 열치료(Rodiofrequency ablotion)에 이용되는 내부 냉각 전극(Internally cooled needle electrodes)를 이용한 간 소작법의 유용성 실험 (An Experimental Study on Hepatic Ablation using an Internally Cooled Needle Electrodes in Radiofrequency Ablation)

  • 한정환;안정현;박원식
    • 대한방사선협회지
    • /
    • 제30권1호
    • /
    • pp.58-62
    • /
    • 2004
  • The purpose of this study was to determine the factors influencing on the size of Radiofrequency ablation using an internally cooled needle electrodes in cattle liver. Ablation procedures involved the use of cool-tip RF system generator and internally coo

  • PDF

간 질환 감별에 있이 MR영상의 역동적 검사와 EPI의 유용성 (Value of Echo-Planar Imaging and MRI Dynamic Study in Differentiation Liver Diseases)

  • 박병래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.73-78
    • /
    • 1997
  • The goal of this paper is that we know the usefulness of echo-planar imaging(EPI) for discriminate between hepatocellular carcinoma(HCC) and hemangioma. We get a time signal intensity curve for liver diseases from the dynamic contrast enhancement images and compared and analyze both the contrast ratio(CR) and the contrast to noise ratio(CNR) using echo planar imaging. The obtained results are follows : 1. Hepatocellular carcinoma was shown the best contrast after about 20 seconds when Is the earlist time in the main artery, and then reduced. The center where is disease was shown the characteristic that the best contrast is appeared after about 35-45 seconds and then slowly reduced. Liver parenchyma was shown the best contrast and reduced after 60 seconds. 2. The peripheral nodular of hemangioma was shown the better contrast soon. On the other hend, the contrast of center where is disease started to increase after 60 seconds and was equal to that of liver parenchyma. Increasing of the contrast continued after. 3. Turbo SE technic was used, the average of CR for hepatocellular carcinoma was $36.7{\pm}1.2$ and the average of CNR was $2.4{\pm}3.2$, while the average of CNR for hemangioma was $54.9{\pm}1.0$ and the average of CNR was $9.7{\pm}1.3$. 4. EPI technic was used, the average of CR for hepatocellular carcinoma was $47.8{\pm}1.2$ and the average of CNR was $3.4{\pm}2.1$, while the average of CNR for hemangioma was $75.7{\pm}2.2$ and the average of CNR was $9.5{\pm}1.1$. According to above we can find that hemangioma is more bright than hepatocellular carcinoma and the difference of brightness between hepatocellular carcinoma and hemangioma is useful sequence.

  • PDF

Optimization of Scan Parameters for in vivo Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopic Imaging

  • Nguyen, Nguyen Trong;Rasanjala, Onila N.M.D.;Park, Ilwoo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권2호
    • /
    • pp.125-134
    • /
    • 2022
  • Purpose: The aim of this study was to investigate the change in signal sensitivity over different acquisition start times and optimize the scanning window to provide the maximal signal sensitivity of [1-13C]pyruvate and its metabolic products, lactate and alanine, using spatially localized hyperpolarized 3D 13C magnetic resonance spectroscopic imaging (MRSI). Materials and Methods: We acquired 3D 13C MRSI data from the brain (n = 3), kidney (n = 3), and liver (n = 3) of rats using a 3T clinical scanner and a custom RF coil after the injection of hyperpolarized [1-13C]pyruvate. For each organ, we obtained three consecutive 3D 13C MRSI datasets with different acquisition start times per animal from a total of three animals. The mean signal-to-noise ratios (SNRs) of pyruvate, lactate, and alanine were calculated and compared between different acquisition start times. Based on the SNRs of lactate and alanine, we identified the optimal acquisition start timing for each organ. Results: For the brain, the acquisition start time of 18 s provided the highest mean SNR of lactate. At 18 s, however, the lactate signal predominantly originated from not the brain, but the blood vessels; therefore, the acquisition start time of 22 s was recommended for 3D 13C MRSI of the rat brain. For the kidney, all three metabolites demonstrated the highest mean SNR at the acquisition start time of 32 s. Similarly, the acquisition start time of 22 s provided the highest SNRs for all three metabolites in the liver. Conclusion: In this study, the acquisition start timing was optimized in an attempt to maximize metabolic signals in hyperpolarized 3D 13C MRSI examination with [1-13C] pyruvate as a substrate. We investigated the changes in metabolic signal sensitivity in the brain, kidney, and liver of rats to establish the optimal acquisition start time for each organ. We expect the results from this study to be of help in future studies.

건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석 (Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units)

  • 오왕균;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.229-235
    • /
    • 2017
  • 상복부초음파검사에서 간실질의 에코 음영증가와 불명확한 혈관경계 등으로 지방간을 진단하는데, 여러 연구들에 의하면 지방간 진단에 84~95%의 특이도와 60~90%의 민감도를 가지나 결과가 검사자에 의존적이어서 차이가 있을 수 있고 지방의 침윤 상태의 정량적인 측정이 불가능하다. 건강검진의 상복부초음파검사와 흉부 전산화단층촬영(computed tomography; CT) 검사를 같은 날에 시행한 수검자중 초음파검사에서 지방간을 진단 받은 환자의 흉부 전산화단층촬영 영상에서 간(Liver) Hounsfield Units(HU)를 측정하여 지방간 진단의 정확성을 연관분석 하고자 하였다. 연구대상 수검자 720명 중 가정의학과 전문의에게 검사를 받고 지방간 판정을 받은 자는 448명으로 62.2%였다. 지방간 판정자의 CT영상에서 간 HU를 측정한 결과 40 HU 이하의 측정값은 720명 중 175명으로 24.3%이며, 초음파에서 진단 받은 448명에 175명 중 173명이 포함되어 98.9%가 일치하였다. 이는 지방간을 초음파로 진단 시 검사자의 주관적 경험과 능력이 병변을 진단하는데 크게 영향을 미친 것으로 생각되며 검진 CT검사에서 간 HU를 측정하여 40 HU 이하는 영상저장을 통하여 지방간 진단 시 참고자료로 활용될 수 있을 것으로 사료된다.

Radiomics and Deep Learning: Hepatic Applications

  • Hyo Jung Park;Bumwoo Park;Seung Soo Lee
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.387-401
    • /
    • 2020
  • Radiomics and deep learning have recently gained attention in the imaging assessment of various liver diseases. Recent research has demonstrated the potential utility of radiomics and deep learning in staging liver fibroses, detecting portal hypertension, characterizing focal hepatic lesions, prognosticating malignant hepatic tumors, and segmenting the liver and liver tumors. In this review, we outline the basic technical aspects of radiomics and deep learning and summarize recent investigations of the application of these techniques in liver disease.