• Title/Summary/Keyword: liquid storage tank

Search Result 210, Processing Time 0.03 seconds

The FEM Analysis of Membrane for LNG Storage Tank (LNG 저장탱크용 멤브레인 개발을 위한 유한요소해석)

  • Oh B.T.;Hong S.H.;Yoon I.S.;Kim Y.K.;Seo H.S.
    • 한국가스학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.35-44
    • /
    • 2001
  • Analytical and experimental studies have been performed to investigate the strength of the membrane and the reaction force at the anchor point. Using nonlinear FEM code and experiments, the stress analysis of the corrugated membrane related the cryogenic liquid pressure and thermal loading is performed to ensure the stability and fatigue strength of the membrane. This paper reports on the FEM results of membrane.

  • PDF

Fault Detection and Diagnosis of the Deaerator System in Nuclear Power Plants (원전 탈기기 시스템의 수위 측정 센서의 고장 검출 및 진단)

  • Kim, Bong-Seok;Lee, In-Soo;Lee, Yoon-Joon;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.107-118
    • /
    • 2003
  • In this paper, dynamic control model is formulated by considering the geometrical structure of the deaerator storage tank in nuclear power plant and input-output flow rate at steady state, and we describe fault detection and diagnosis (FDD) scheme based on the adaptive estimator. The performance and effectiveness of the proposed FDD scheme are evaluated by applying real operating data obtained from the YOUNGKWANG 3 & 4 FSAR.

  • PDF

The Improvement of the Performance of Solar Cooling and Heating Systems (III) - Development of One Dimensional Analytic Model for the Evaluation of Stratification Coefficients - (태양열에 의한 냉방 및 난방시스템의 성능향상 (III) - 성층화계수의 예측을 위한 1차원 해석모델의 개발 -)

  • Yoo, J.K.;Ro, S.T.;Lee, J.S.;Chung, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-63
    • /
    • 1989
  • A one dimensional analytic model for the prediction of the stratification coefficient of a liquid-based solar heating system is developed. The stratification coefficient, $K_s$, is defined as the ratio of the actual useful energy gain to the energy gain that would be achieved if there were no thermal stratification in the storage tank. Previous studies incorporated only collector-side effects, but in this study both the collector and load-side effects are included for the overall performance evaluation.

  • PDF

Earthquake Buckling Analysis of Liquid Storage Tank by Added Mass Model (추가질량 모델에 의한 유체저장 탱크의 지진좌굴해석)

  • Kang, Bo-Ram;Kim, Se-Jeong;Lee, Gye-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.43-46
    • /
    • 2010
  • 본 연구에서는 유체가 담긴 원통형 유체저장탱크의 지진에 의한 좌굴을 수행하였다. 해석에 사용된 유체 저장탱크는 바닥이 앵커로 고정된 3차원 유한요소모델로 모델링 하였으며, 탱크 벽체와 지붕은 쉘 요소로, 지붕보강재는 프레임요소를 사용하여 모델링 하였다. 유체-탱크 모델은 Veletsos와 Shivakumar의 추가 질량법에 근거하여 지진에 의한 유체 압력은 탱크 벽에 수직으로 작용하도록 모델링 하였다. 2007년 일본에서 발생한 지진가속도를 사용하여 범용 유한요소 프로그램인 ABAQUS로 좌굴해석을 수행하였다.

  • PDF

Volume Variation of Liquid Fuel by Seasonal, Regional Temperature Changes (계절적, 지역적 온도 변화에 따른 석유류 체적의 변화)

  • Lim, Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.155-163
    • /
    • 2014
  • At gas stations, liquid fuels expand and contract in volume owing to temperature variations. In Korea, the ambient temperature varies between $-15^{\circ}C$ in winter and $35^{\circ}C$ in summer. The volume expansion coefficients of liquid fuels are about $0.1%/^{\circ}C$. To investigate this issue, we measured daily changes in fuel temperature and the delivered fuel temperature at gas stations. In addition, we scrutinized the daily, monthly, and annual changes in temperature over past 50 years in Korea. The results show that the temperature of the fuel in the storage tank was maintained at a stable value(summer or winter). Many factors, such as the surrounding conditions, fuel filling frequency, and gas station location, influence the delivered fuel temperature. The results of this study can be applied for establishing a national regulation and will contribute to fair transactions.

Design and Economic Analysis of Low Pressure Liquid Air Production Process using LNG cold energy (LNG 냉열을 활용한 저압 액화 공기 생산 공정 설계 및 경제성 평가)

  • Mun, Haneul;Jung, Geonho;Lee, Inkyu
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.345-358
    • /
    • 2021
  • This study focuses on the development of the liquid air production process that uses LNG (liquefied natural gas) cold energy which usually wasted during the regasification stage. The liquid air can be transported to the LNG exporter, and it can be utilized as the cold source to replace certain amount of refrigerant for the natural gas liquefaction. Therefore, the condition of the liquid air has to satisfy the available pressure of LNG storage tank. To satisfy pressure constraint of the membrane type LNG tank, proposed process is designed to produce liquid air at 1.3bar. In proposed process, the air is precooled by heat exchange with LNG and subcooled by nitrogen refrigeration cycle. When the amount of transported liquid air is as large as the capacity of the LNG carrier, it could be economical in terms of the transportation cost. In addition, larger liquid air can give more cold energy that can be used in natural gas liquefaction plant. To analyze the effect of the liquid air production amount, under the same LNG supply condition, the proposed process is simulated under 3 different air flow rate: 0.50 kg/s, 0.75 kg/s, 1.00 kg/s, correspond to Case1, Case2, and Case3, respectively. Each case was analyzed thermodynamically and economically. It shows a tendency that the more liquid air production, the more energy demanded per same mass of product as Case3 is 0.18kWh higher than Base case. In consequence the production cost per 1 kg liquid air in Case3 was $0.0172 higher. However, as liquid air production increases, the transportation cost per 1 kg liquid air has reduced by $0.0395. In terms of overall cost, Case 3 confirmed that liquid air can be produced and transported with $0.0223 less per kilogram than Base case.

The Hybrid Rocket Internal Ballistics with Two-phase Fluid Modeling for Self-pressurizing $N_2O$ I (자발가압 성질을 가진 아산화질소의 2상유체 모델링을 통한 하이브리드 로켓 내탄도 해석 I)

  • Lee, Jung-Pyo;Rhee, Sun-Jae;Woo, Kyoung-Jin;Oh, Ji-Sung;Jung, Sik-Hang;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.45-49
    • /
    • 2011
  • The blow-down oxidizer feed system with self-pressurizing $N_2O$ has more advantages than the regulated system. However, it is difficult to predict the exhaust flow rate because there exist two phases in the $N_2O$ tank - liquid phase and gas phase, and the properties of $N_2O$ in storage tank are varied continuously during blow-down. In this paper, a method that can analyse simply the blow-down oxidizer feed system is studied. The properties of saturated $N_2O$ are found from the NIST data base, and mass flow through the orifice is modeled as NHNE. Cold flow test with hybrid rocket combustor is performed for the comparison where the results should found from the good agreement.

  • PDF

Studies on the Sorption and Fixation of Cesium by Vermiculite (II)

  • Lee, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.97-111
    • /
    • 1974
  • The adsorption mechanism of Cs-137 in low level radioactive solution by vermiculite treated with Na ion is studied in order to investigate its effective utilization for the radioactive effluent treatment. The beneficial role of Na-vermiculite is that Na ion can induce the wider c-axis spacing in which Cs ion can be sorbed in vermiculite. Cation exchange capacity and distribution coefficient of cesium seems to be influenced by the variation of c-axis spacing of vermiculite. Comparative identification and detection with the characteristic analyses of X-ray diffraction and electron diffraction patterns, diffrential thermal analysis and electron microscopy of Na-, K- and Cs-vermiculite are studied for the phemomena of Cs adsorption by vermiculite. This importance of the utilization in terms of adsorption and fixation of cesium involving vermiculite is discussed. It is found that the Na-vermiculite is valuable outside charging material for high level radioactive liquid waste storage tank of underground to protect the pollution of the underground water.

  • PDF

Analysis of cooling phenomenon of water with the supercooled (과냉각을 동반한 순수물의 냉각현상 해석)

  • Chu, Mi-Seon;Yun, Jeong-In;Kim, Jae-Dol;Kamata, Yoshinobu;Kato, Toyofumi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.862-872
    • /
    • 1997
  • Ice formation in a horizontal circular cylinder has been studied numerically. From the numerical analysis results, it was found that there were three types of freezing pattern and that freezing phenomenon was affected largely by density inversion and cooling rate. The type of freezing pattern largely depends on the secondary flow which is generated by density inversion. When supercooling energy is released before the development of the secondary flow, the annular ice layer grows. If the energy is released when the secondary flow is considerably developed and the supercooled region is removed to the upper half part of the cylinder, an asymmetric ice layer grows. And if the energy is released after perfect development of the secondary flow, instantaneous dendritic ice formation over the full region occurs. Furthermore, this secondary flow was found to have an effect on heat transfer characteristics. The heat transfer rate becomes small at the instant when the secondary flow is generated, but becomes large with the development of the flow. It's concluded that for the facilitation of heat transfer it is desirable to keep water in liquid phase until the secondary flow is perfectly developed. This study gave an instruction of performance improvement of capsule type ice storage tank.

Numerical Analysis on Melting Phenomena and Phase Interface Change of Frozen Urea-aqueous Solution by Electric Heater (전기 히터 방식의 동결 우레아 해동 현상 및 상경계면 이동에 대한 수치해석)

  • Woo, Seongmin;Choi, Byungchul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.13-19
    • /
    • 2014
  • Urea-SCR system is the selective catalytic reduction to reduce nitrogen oxides ($NO_x$) emitted from diesel vehicles. The objective of this study is numerical analysis of 3-dimensional unsteady melting problems of frozen urea by using an electric heater. It can be applied to determine capacity of power with respect to time and the location of the urea suction pipe in urea storage tank. The study includes the change of liquid volume fraction, temperature profiles and a influence of natural convection by using the commercial software STAR-CCM+(v7.06). The accuracy of the numerical analysis is estimated by comparisons with experimental data. After validation, a numerical analysis for freezing urea is conducted with four different heating power. From the results, it was found that relation of velocity of phase interface and amount of melting urea by increasing heating power in a container. There is also a difference in trend between velocity of phase interface and amounts of melting urea because of effect of natural convection.