Volume Variation of Liquid Fuel by Seasonal, Regional Temperature Changes  

Lim, Ki Won (Korea Research Institute of Standards and Science Center for Fluid Flow &Acoustics)
Publication Information
Transactions of the Korean Society of Mechanical Engineers B / v.38, no.2, 2014 , pp. 155-163 More about this Journal
Abstract
At gas stations, liquid fuels expand and contract in volume owing to temperature variations. In Korea, the ambient temperature varies between $-15^{\circ}C$ in winter and $35^{\circ}C$ in summer. The volume expansion coefficients of liquid fuels are about $0.1%/^{\circ}C$. To investigate this issue, we measured daily changes in fuel temperature and the delivered fuel temperature at gas stations. In addition, we scrutinized the daily, monthly, and annual changes in temperature over past 50 years in Korea. The results show that the temperature of the fuel in the storage tank was maintained at a stable value(summer or winter). Many factors, such as the surrounding conditions, fuel filling frequency, and gas station location, influence the delivered fuel temperature. The results of this study can be applied for establishing a national regulation and will contribute to fair transactions.
Keywords
Liquid Fuel; Thermal Expansion Coefficient; Automatic Temperature Compensator; Flow Measurement; Gas Station; Petroleum;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lim, K. W., 2001,"A study on the Measurement Uncertainty of Flowmeter Calibrator,"Trans. Korean Soc. Mech. Eng. B, Vol. 25, No. 1, pp 561-571.   과학기술학회마을
2 JFI Standard 1001, 1975,"Meter Accuracy Tests of Positive displacement Flowmeters I," Japan Flow Meter Industry Association, Japan (in Japanese)
3 Energy Economics Institute, 2011," 2010 yearbook of Energy Statics," Ministry of Knowledge Economy, ISSN 1226-606X, Korea (in Korean)
4 Paton, R., Boam, D., Millington, B. C. and Kinghorn, F.C., 1999, "Temperature Compensation of Liquid Fuels," NEL, Repot No. 184/99, UK
5 California Energy Commission, 2009, "Fuel Delivery Temperature Study," Report No. CEC-600-2009-002- CTF, USA.
6 Weight and Measure Act, Regulation of Liquid Fuels, 2004, "Field Inspection Manual-Volumetric Measuring Device (Automatic Temperature Compensator Test)," Canada
7 Korea Regulation, 2009 "Regulation Related to Safety Supervision of Dangerous Substance - Standard of Structure and Arrangement for Underground Storage Tank(article 32 Related)," National Emergency Management Agency, Korea (in Korean).