• 제목/요약/키워드: liquid sloshing

검색결과 170건 처리시간 0.031초

유체요소를 이용한 직사각형 유체 저장구조물의 지진해석 (Seismic Analysis of Rectangular Liquid Storage Structures Ssing Fluid Elements)

  • 김영석;김제민;윤정방
    • 한국해양공학회지
    • /
    • 제6권2호
    • /
    • pp.46-54
    • /
    • 1992
  • In this paper, behavior of rectangular storage structures under earthquake loadings are investigated. Linear sloshing is assumed in this study. The effect of the wall flexibility is considered. Eulerian and lagrangian approaches are presented. The Eulerian approach is carried out by solving the boundary value problem for the fluid motion. In the lagrangian approach, the fluid as well as the storage structure is modelled by the finite element method. The fluid region is discretized by using fluid elements. The (1 $\times$ 1)-reduced integration is carried out for constructing the stiffness matrices of the fluid elements. Seismic analysis of the coupled system is carried out by the response spectra method. The numerical results show that the fluid forces on the wall obtained by two approaches are in good agreements. By including the effect of the wall flexibility, the forces due to fluid motion can be increased very significantly.

  • PDF

New coefficients to find natural period of elevated tanks considering fluid-structure-soil interaction effects

  • Maedeh, Pouyan Abbasi;Ghanbari, Ali;Wu, Wei
    • Geomechanics and Engineering
    • /
    • 제12권6호
    • /
    • pp.949-963
    • /
    • 2017
  • The main purpose of the current study is to develop the new coefficients for consideration of soil-structure interaction effects to find the elevated tank natural period. Most of the recommended relations to find the natural period just assumed the fixed base condition of elevated tank systems and the soil effects on the natural period are neglected. Two different analytical systems considering soil-structure- fluid interaction effects are recommended in the current study. Achieved results of natural impulsive and convective period, concluded from mentioned models are compared with the results of a numerical model. Two different sets of new coefficients for impulsive and convective periods are developed. The values of the developed coefficients directly depend to soil stiffness values. Additional results show that the soil stiffness not only has significant effects on natural period but also it is effective on liquid sloshing wave height. Both frequency content and soil stiffness have significant effects on the values of liquid wave height.

지반-구조물 상호작용을 고려한 원통형 유체저장탱크의 지진해석 (Earthquake Analaysis of Cylindrical Liquid Storage tanks Considering Effects of Soil-Structure Interaction)

  • 김재민
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.83-90
    • /
    • 1999
  • This paper presents a method of seismic analysis for a cylindrical liquid storage structure on horizontally layered half-space considering the effects of the interior fluid and exterior soil medium in the frequency domain. the horizontal and rocking motions of the structures are included in this study. The fluid motion is expressed in terms of analytical velocity potential function which can be obtained by solving the boundary value problem including the sloshing behavior of the fluid as well as deformed configuration of the structure. The effect of the fluid is included in the equation of motion as the impulsive added mass and a frequency-dependent convective added mass along the nodes on the wetted boundary with structure. The soil medium is presented using the 3-D axisymmetric finite elements and dynamic infinite elements. The present method can be applied to the structures embedded in ground as well as on ground since it models the soil medium directly as well as the structure. For the purpose of vertification dynamci characteristics of a tank on homogeneous half-space is analyzed. Comparison of the present results with those by others shows good agreement.

  • PDF

실물크기 구조물에 설치된 동조액체질량감쇠기의 성능실험 (Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure)

  • 허재성;박은천;이성경;이상현;김홍진;조지성;조봉호;주석준;민경원
    • 한국전산구조공학회논문집
    • /
    • 제21권2호
    • /
    • pp.161-168
    • /
    • 2008
  • 본 연구에서는 하나의 제어장치로 서로 직교하는 2방향의 건물응답을 동시에 제어할 수 있는 동조액체질량감쇠기(Tuned Liquid Mass Damper; TLMD)를 제안하고 제어성능을 실험적으로 검증하였다. 본 연구에서 제안된 TLMD는 한 방향으로는 동조액체기둥감쇠기(Tuned Liquid Column Damper; TLCD) 내부에 채워진 액체의 운동에너지를 이용하여 구조물의 응답을 제어하게 된다. 그리고, 다른 한 방향 즉 TLCD의 직각 방향으로는 LM guide(linear motion guide) 위에 놓인 TLCD 수조와 내부의 액체의 질량을 이용하여 동조질량감쇠기(Tuned Mass Damper; TMD)로 거동하게 함으로써 구조물의 응답을 감소시킨다. 이와 같은 TLMD의 양방향 독립거동 특성을 증명하기 위해 실물크기의 구조물에 설치하여 강제진동실험을 수행하였다. 실험결과, 양방향 모두 대상 구조물의 응답을 감소시키는 것을 확인하여 제안된 TLMD의 효용성을 검증하였다.

동요하는 탱크의 내부 변동압력 추정에 관한 연구 (On the Prediction of Inner Pressure for the Tank in Rolling Motion)

  • 이승건;서영석
    • 한국항해항만학회지
    • /
    • 제27권5호
    • /
    • pp.459-464
    • /
    • 2003
  • 강제 횡동요 실험을 통하여 동요하는 탱크의 내부압력을 폭정하고, 탱크의 내부압력을 추정하는 간단한 이론식을 제시하였다. 청수로 채워진 사각 탱크를 동요실험에 사용하였으며, 탱크의 안쪽 벽과 바닥에 압력게이지를 설치하여 내부압력의 시간변화량을 측정하였다. 측정된 탱크의 내부압력의 실험값과 이론식을 이용한 계산값을 비교하였다. 횡동요 하는 탱크내부의 압력을 구하기 위해 압력중심을 고려하여 추정하는 방법을 연구하였다.

Effect of higher modes and multi-directional seismic excitations on power plant liquid storage pools

  • Eswaran, M.;Reddy, G.R.;Singh, R.K.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.779-799
    • /
    • 2015
  • The slosh height and the possibility of water spill from rectangular Spent Fuel Storage Bays (SFSB) and Tray Loading Bays (TLB) of Nuclear power plant (NPP) are studied during 0.2 g, Safe Shutdown Earthquake (SSE) level of earthquake. The slosh height obtained through Computational Fluid dynamics (CFD) is compared the values given by TID-7024 (Housner 1963) and American concrete institute (ACI) seismic codes. An equivalent amplitude method is used to compute the slosh height through CFD. Numerically computed slosh height for first mode of vibration is found to be in agreement the codal values. The combined effect in longitudinal and lateral directions are studied separately, and found that the slosh height is increased by 24.3% and 38.9% along length and width directions respectively. There is no liquid spillage under SSE level of earthquake data in SFSB and TLB at convective level and at free surface acceleration data. Since seismic design codes do not have guidelines for combined excitations and effect of higher modes for irregular geometries, this CFD procedure can be opted for any geometries to study effect of higher modes and combined three directional excitations.

Fluid-structure-soil interaction analysis of cylindrical liquid storage tanks subjected to horizontal earthquake loading

  • Kim, Jae-Min;Chang, Soo-Hyuk;Yun, Chung-Bang
    • Structural Engineering and Mechanics
    • /
    • 제13권6호
    • /
    • pp.615-638
    • /
    • 2002
  • This paper presents a method of seismic analysis for a cylindrical liquid storage structure considering the effects of the interior fluid and exterior soil medium in the frequency domain. The horizontal and rocking motions of the structure are included in this study. The fluid motion is expressed in terms of analytical velocity potential functions, which can be obtained by solving the boundary value problem including the deformed configuration of the structure as well as the sloshing behavior of the fluid. The effect of the fluid is included in the equation of motion as the impulsive added mass and the frequency-dependent convective added mass along the nodes on the wetted boundary of the structure. The structure and the near-field soil medium are represented using the axisymmetric finite elements, while the far-field soil is modeled using dynamic infinite elements. The present method can be applied to the structure embedded in ground as well as on ground, since it models both the soil medium and the structure directly. For the purpose of verification, earthquake response analyses are performed on several cases of liquid tanks on a rigid ground and on a homogeneous elastic half-space. Comparison of the present results with those by other methods shows good agreement. Finally, an application example of a reinforced concrete tank on a horizontally layered soil with a rigid bedrock is presented to demonstrate the importance of the soil-structure interaction effects in the seismic analysis for large liquid storage tanks.

Seismic behavior of liquid storage tanks with 2D and 3D base isolation systems

  • Kilic, Samet;Akbas, Bulent;Shen, Jay;Paolacci, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.627-644
    • /
    • 2022
  • In past major earthquakes (1994 Northridge, 1995 Kobe, Chi-Chi 1999, Kocaeli 1999), significant damages occurred in the liquid storage tanks. The basic failure patterns were observed to be the buckling of the tank wall and uplift of the anchorage system. The damages in the industrial facilities and nuclear power plants have caused the spread of toxic substances to the environment and significant fires. Seismic isolation can be used in liquid storage tanks to decouple the structure and decrease the structural demand in the superstructure in case of ground shaking. Previous studies on the use of seismic isolation systems on liquid storage tanks show that an isolation system reduces the impulsive response but might slightly increase the convective one. There is still a lack of understanding of the seismic response of seismically isolated liquid storage tanks considering the fluid-structure interaction. In this study, one broad tank, one medium tank, and one slender tank are selected and designed. Two- and three-dimensional elastomeric bearings are used as seismic isolation systems. The seismic performance of the tanks is then investigated through nonlinear dynamic time-history analyses. The effectiveness of each seismic isolation system on tanks' performance was investigated. Isolator tension forces, modal analysis results, hydrodynamic stresses, strains, sloshing heights and base shear forces of the tanks are compared. The results show that the total base shear is lower in 3D-isolators compared to 2D-isolators. Even though the tank wall stresses, and strains are slightly higher in 3D-isolators, they are more efficient to prevent the tension problem.

액체 저장구조물의 유체-구조물 상호작용 해석 (FLUID-STRUCTURE INTERACTION ANALYSIS OF LIQUID STORAGE STRUCTURES)

  • 윤정방;김진웅;서정문;전영선
    • 전산구조공학
    • /
    • 제5권4호
    • /
    • pp.103-111
    • /
    • 1992
  • 본 논문에서는 직사각형 형태의 사용후 핵연료 저장구조물에 대한 내진해석을 다루었다. Eulerian과 Lagrangian의 두가지 해석방법을 사용하여, 그 결과를 비교하였다. Eulerian접근방법에서는 유체 운동에 대한 Laplace방정식의 경계치 문제를 푼 반면, Lagrangian 접근방법에서는 저장구조물은 고체 유한요소로 모형화 하였고, 내부유체는 유체 유한요소로 모형화 하였다. 유체영역을 모형화 하는데 사용된 유체요소의 강성을 적절히 산정하기 위하여 (1*1)의 감차적분을 적용하였다. 응답스펙트럼해석법으로 유체-구조물 상관관계의 내진해석을 수행한 결과, 두 접근방법으로 구한 벽면에 작용하는 유동압이 잘 일치함을 알 수 있었다. 또한 벽면 유연성의 영향을 포함할 경우, 지진 발생시 벽면에 작용하는 유동압이 크게 증가할 수 있음을 알았다.

  • PDF

다양한 수평 수직 단면적비를 가지는 LCVA의 진동특성 평가 (Vibration Characteristics of Liquid Column Vibration Absorber with Various Area Ratio)

  • 정란;이정우;박현진;이상현;우성식;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.121-125
    • /
    • 2007
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA is larger than the calculated one when the area ratio is larger than 1. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF