• 제목/요약/키워드: liquid sloshing

검색결과 171건 처리시간 0.025초

2차원 사각형 주상체의 횡동요 및 2자유도 운동에 미치는 슬로싱의 영향 (The Sloshing Effect on the Roll Motion and 2-DoF Motions of a 2D Rectangular Cylinder)

  • 김윤호;성홍근;조석규;최항순
    • 대한조선학회논문집
    • /
    • 제50권2호
    • /
    • pp.69-78
    • /
    • 2013
  • This study is constructed to investigate the sloshing effect on the motions of a two-dimensional rectangular cylinder experimentally and numerically. The modes of motion under consideration are sway and roll, and also experimental cases are divided by two categories; 1-DoF roll motion and 2-DoF motion (Coupling sway and roll). It is found that the sway response is considerably affected by the motion of the fluid, particularly near the sloshing natural frequency, while the roll response changes comparatively small. The dominant mode of motion is analyzed for 2-DoF experiments as well. The measured data for 1-DoF motions is compared with numerical results obtained by the Multi-modal approach. The numerical schemes vary in detail with the number of dominant sloshing modes; i.e. there is a single dominant mode for the Single-dominant method, while the Model 2 method assumes that the first two modes are superior. For the roll motion, numerical results obtained by the two different methods are relatively in good agreement with the experiments, and these two results are similar in most wave frequency range. However, the discrepancies are apparent where the fluid motion is not governed by a single mode. But both of numerical methods over-predict the motion at the vicinity of the sloshing natural frequency. In order to correct the discrepancy, the modal damping needs to be investigated more precisely. Furthermore, another multi-modal approach, such as the Boussinesq-type method, seems to be required in the region of the intermediate liquid.

배플개수 및 내경변화에 따른 액체 저장탱크의 동억제 효과 (Dynamic Suppression Effects of Liquid Container to the Baffle Number and Hole Diameter)

  • 조진래;김민정;이상영;허진욱
    • 한국전산구조공학회논문집
    • /
    • 제15권1호
    • /
    • pp.147-154
    • /
    • 2002
  • 수직방향 가속도를 받는 원통형 액체 저장탱크는 내부유체의 슬로싱(sloshing)에 의한 동하중에 의하여 구조 및 제어성능 안정성에 심각한 영향을 받을 수 있다. 더욱이 유체의 슬로싱 진동수가 제어계 혹은 탱크구조물의 고유진동수 근처에 있게되면 발사체에 큰 동하중과 모멘트를 유발하게 된다. 이와 같은 유체의 동적 효과를 억제하기 위하여 일반적으로 링형 탄성체 배플(baffle)을 채용하고 있다. 본 논문에서는 배플의 개수와 내경을 변수로 설정하여 배플의 동적억제효과를 평가 및 분석하기 위한 수치해석을 수행한다. 배플내경에 따른 파라메트릭 해석과, 탱크높이 및 유체높이를 각각 균등 분할하여 설치된 배들에 대한 동억제 효과를 분석한다. 유체와 구조물 사이의 정확하고 효과적인 연계해석을 위하여 ALE(arbitrary Lagrangin-Eulerian) 수치해석 기법을 적용한다.

The efficiency and robustness of a uni-directional tuned liquid damper and modelling with an equivalent TMD

  • Tait, M.J.;Isyumov, N.;El Damatty, A.A.
    • Wind and Structures
    • /
    • 제7권4호
    • /
    • pp.235-250
    • /
    • 2004
  • The current study reports the results of an experimental program conducted on a structure fitted with a liquid damper (TLD) and subjected to harmonic excitation. Screens were placed inside the TLD to achieve the required inherent damping. In the first part of the study, reduced scale models of the building-TLD systems were tested under two levels of excitation. The efficiency of the damper was assessed by evaluating the effective damping provided to the structure and comparing it to the optimum effective damping value, provided by a linear tuned mass damper (TMD). An extensive parametric study was then conducted for one of the three models by varying both the excitation amplitude and the tuning ratio, defined as the ratio of the TLD sloshing frequency to the natural frequency of the structure. The effectiveness and robustness of a TLD with screens were assessed. Results indicate that the TLD can be tuned to achieve a robust performance and that its efficiency is not significantly affected by the level of excitation. Finally, the equivalent amplitude dependent TMD model, developed in the companion paper is validated using the system test results.

Testing of tuned liquid damper with screens and development of equivalent TMD model

  • Tait, M.J.;El Damatty, A.A.;Isyumov, N.
    • Wind and Structures
    • /
    • 제7권4호
    • /
    • pp.215-234
    • /
    • 2004
  • The tuned liquid damper (TLD) is increasingly being used as an economical and effective vibration absorber. It consists of a water tank having the fundamental sloshing fluid frequency tuned to the natural frequency of the structure. In order to perform efficiently, the TLD must possess a certain amount of inherent damping. This can be achieved by placing screens inside the tank. The current study experimentally investigates the behaviour of a TLD equipped with damping screens. A series of shake table tests are conducted in order to assess the effect of the screens on the free surface motion, the base shear forces and the amount of energy dissipated. The variation of these parameters with the level of excitation is also studied. Finally, an amplitude dependent equivalent tuned mass damper (TMD), representing the TLD, is determined based on the experimental results. The dynamic characteristics of this equivalent TMD, in terms of mass, stiffness and damping parameters are determined by energy equivalence. The above parameters are expressed in terms of the base excitation amplitude. The parameters are compared to those obtained using linear small amplitude wave theory. The validity of this nonlinear model is examined in the companion paper.

수평진동이 있는 용기내 자성유체 액면 동요 현상에 관한 연구 (A Study on Fluid Surface Movement Phenomena of Magnetic Fluids in a Container Subjected to a Horizontal Oscillation)

  • 김대완;박정우;서이수
    • 한국자기학회지
    • /
    • 제22권5호
    • /
    • pp.183-187
    • /
    • 2012
  • 본 논문에서는 수평진동이 있는 용기내 자유표면을 갖는 자성유체에 용기하부로부터 수직자장을 인가시킨 경우 유동을 실험하였다. 실험은 직사각형 및 원통형 용기에 대해 자성유체에 인가된 자기력이 공진주파수, 액면변위에 미치는 영향을 조사하였다. 인가자장의 증가는 최대 공진점 및 액면변위에 영향을 미치고 그 결과 표면파의 진폭과 슬로싱 유동의 변동주기를 변화시킨다.

Response of base-isolated liquid storage tanks to near-fault motions

  • Jadhav, M.B.;Jangid, R.S.
    • Structural Engineering and Mechanics
    • /
    • 제23권6호
    • /
    • pp.615-634
    • /
    • 2006
  • Seismic response of the liquid storage tanks isolated by the elastomeric bearings and sliding systems is investigated under near-fault earthquake motions. The fault normal and parallel components of near-fault motion are applied in two horizontal directions of the tank. The continuous liquid mass of the tank is modeled as lumped masses known as sloshing mass, impulsive mass and rigid mass. The corresponding stiffness associated with these lumped masses has been worked out depending upon the properties of the tank wall and liquid mass. It is observed that the resultant response of the isolated tank is mainly governed by fault normal component with minor contribution from the fault parallel component. Further, a parametric study is also carried out to study the effects of important system parameters on the effectiveness of seismic isolation for liquid storage tanks. The various important parameters considered are: aspect ratio of tank, the period of isolation and the damping of isolation bearings. There exists an optimum value of isolation damping for which the base shear in the tank attains the minimum value under near-fault motion. The increase of damping beyond the optimum value will reduce the bearing and sloshing displacements but increases the base shear. A comparative performance of five isolation systems for liquid storage tanks is also studied under normal component of near-fault motion and found that the EDF type isolation system may be a better choice for design of isolated tank in near-fault locations. Finally, it is also observed that the satisfactory response can be obtained by analysing the base-isolated tanks under simple cycloidal pulse instead of complete acceleration history.

Experimental study on models of cylindrical steel tanks under mining tremors and moderate earthquakes

  • Burkacki, Daniel;Jankowski, Robert
    • Earthquakes and Structures
    • /
    • 제17권2호
    • /
    • pp.175-189
    • /
    • 2019
  • The aim of the study is to show the results of complex shaking table experimental investigation focused on the response of two models of cylindrical steel tanks under mining tremors and moderate earthquakes, including the aspects of diagnosis of structural damage. Firstly, the impact and the sweep-sine tests have been carried out, so as to determine the dynamic properties of models filled with different levels of liquid. Then, the models have been subjected to seismic and paraseismic excitations. Finally, one fully filled structure has been tested after introducing two different types of damages, so as to verify the method of damage diagnosis. The results of the impact and the sweep-sine tests show that filling the models with liquid leads to substantial reduction in natural frequencies, due to gradually increasing overall mass. Moreover, the results of sweep-sine tests clearly indicate that the increase in the liquid level results in significant increase in the damping structural ratio, which is the effect of damping properties of liquid due to its sloshing. The results of seismic and paraseismic tests indicate that filling the tank with liquid leads initially to considerable reduction in values of acceleration (damping effect of liquid sloshing); however, beyond a certain level of water filling, this regularity is inverted and acceleration values increase (effect of increasing total mass of the structure). Moreover, comparison of the responses under mining tremors and moderate earthquakes indicate that the power amplification factor of the mining tremors may be larger than the seismic power amplification factor. Finally, the results of damage diagnosis of fully filled steel tank model indicate that the forms of the Fourier spectra, together with the frequency and power spectral density values, can be directly related to the specific type of structural damage. They show a decrease in the natural frequencies for the model with unscrewed support bolts (global type of damage), while cutting the welds (local type of damage) has resulted in significant increase in values of the power spectral density for higher vibration modes.

멤브레인형 LNG 화물창의 강도평가를 위해 적용된 분사모델을 이용한 유체구조 연성해석에 관한 연구 (Fluid Structure Interaction Analysis of Membrane Type LNG CCS Experiencing the Sloshing Impact by Impinging Jet Model)

  • 황세윤;이장현
    • 한국전산구조공학회논문집
    • /
    • 제28권1호
    • /
    • pp.71-78
    • /
    • 2015
  • LNG 선박에서 발생하는 슬로싱 충격하중은 다상유동 및 기체의 압축효과에 따라 CCS에서 발생하는 압력과 구조응답에 큰 영향을 미칠 수 있다. 본 연구에서는 슬로싱 운동 시 LNG의 유동에 의해 발생하는 슬로싱 충격을 시뮬레이션하기 위해서 다상유동을 적용한 수치해석 모델을 제시하였으며, 그 결과를 실험과 비교하여 타당성을 검토하였다. 또한 효율적인 구조 응답 계산을 위해 분사모델을 이용한 유체구조 연성해석 방법에 대해서 검토하고 멤브레인형 Mark III 화물창의 강도평가에 적용하여 LNG 화물창의 강도평가를 위한 가능성을 검토하였다.

Moment of inertia of liquid in a tank

  • Lee, Gyeong Joong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권1호
    • /
    • pp.132-150
    • /
    • 2014
  • In this study, the inertial properties of fully filled liquid in a tank were studied based on the potential theory. The analytic solution was obtained for the rectangular tank, and the numerical solutions using Green's 2nd identity were obtained for other shapes. The inertia of liquid behaves like solid in recti-linear acceleration. But under rotational acceleration, the moment of inertia of liquid becomes small compared to that of solid. The shapes of tank investigated in this study were ellipse, rectangle, hexagon, and octagon with various aspect ratios. The numerical solutions were compared with analytic solution, and an ad hoc semi-analytical approximate formula is proposed herein and this formula gives very good predictions for the moment of inertia of the liquid in a tank of several different geometrical shapes. The results of this study will be useful in analyzing of the motion of LNG/LPG tanker, liquid cargo ship, and damaged ship.

유체-구조물-지반 상호작용을 고려한 면진된 유체저장탱크의 3차원 지진응답 (Seismic Response of Base-Isolated Liquid Storage Tanks Considering Liquid-Structure-Soil Interaction)

  • 조성용;김문겸;임윤묵
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.98-105
    • /
    • 2002
  • The effects of the base-isolation system and elastic soil foundation on the behavior of a liquid storage tank are studied. To evaluate the seismic response of liquid storage tank accurately, the coupled dynamic system considering base isolation and soil interaction problem is formulated in time domain. Results show that the base isolation system reduces effectively the radial displacements, base shears, overturning moments, axial resultant stresses and the hydrodynamic pressure by providing flexibility and energy dissipation capability. Base Isolation may, however, increase the relative liquid sloshing amplitude due to the effect of liquid-structure interaction and cause excessive large relative displacements between structure and foundation. In addition to base-isolator, the dynamic behavior of liquid storage tank is related to the flexibility of base foundation, so the analysis of soil-structure interaction s achieved.

  • PDF