• Title/Summary/Keyword: liquid phase

Search Result 4,301, Processing Time 0.036 seconds

Feasibility Evaluation for Remediation of Groundwater Contaminated with Heavy Metal using Calcium Polysulfide in Homogeneous media (균질한 매질 내 Calcium polysulfide 주입에 따른 고농도 중금속 오염 지하수 정화 타당성 검토)

  • Hyeon Woo Go;Jin Chul Joo;Kyoungphile Nam;Hee Sun Moon;Sung Hee Yoon;Dong Hwi Lee;So Ye Jang
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • In this study, column tests using relatively uniform Jumunjin sand media were conducted to evaluate the feasibility of calcium polysulfide (CaSx, CPS) in removing high concentration of Zn2+ in groundwater. The injected CPS solution reacted rapidly with Zn2+ in artificial groundwater and effectively reduced Zn2+ by more than 99% through metal sulfide precipitation. Since the density (d = 1.27 g/cm3 ) of CPS solution was greater than that of water, CPS solution settled down rapidly while capturing Zn2+ and formed stable CPS layer similar to dense nonaqueous phase liquid. Mass balance analysis on Zn2+ in CPS solution suggested that CPS solution effectively reacted with Zn2+ to form metal sulfide precipitates except for high groundwater seepage velocity of 400 cm/d. With greater groundwater seepage velocity, injected CPS did not completely dissolve at the CPS-water interface, but a partially-misible CPS layer continuously moved and reacted with Zn2++ in the direction of groundwater flow. Since hydraulic conductivity (Kh) decreased slightly due to the generated metal precipitates in the inter-pores of media, injection of CPS solution should be optimized to prevent clogging. As evidenced by both XRF and SEM/EDS results, ZnS precipitates were clearly observed through the reaction between the CPS solution and Zn2+. Further study is warranted to evaluate the feasibility of CPS to remove high-concentration heavy metalcontaminated groundwater in complex and heterogeneous media.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

Vitrification of Highly Active Liquid Waste(II) (The thermal decomposition of HARVEST feed slurries and the characterization of the product)

  • Chun, K.S.;Morris, J.B.
    • Nuclear Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.203-212
    • /
    • 1979
  • The thermal decomposition of simulated Magnox highly active waste and of HARVEST feed slurries (SW and SG) which include tile glass forming chemicals has been studied. The waste and the slurries are almost completely calcined by 500-55$0^{\circ}C$. The colour of the solids from the slurries varies little until about 90$0^{\circ}C$ when it darkens considerably. The slurries begin to vitrify at this temperature and are completely vitrified at 1000-105$0^{\circ}C$. On the other hand. the sulphate impurity in SN slurry causes a yellow phase to separate above 75$0^{\circ}C$. The density of the intermediate solids is fairly low until 650$^{\circ}$-$700^{\circ}C$ is reached. This temperature seems to mark the onset of fluxing as tile density rises quickly to 2g/㎤ at 700$^{\circ}$ -80$0^{\circ}C$. The strengh of the solids decreases with temperature up to 50$0^{\circ}C$, and then rises as the solids begin to sinter. Below 50$0^{\circ}C$ the SN solids are the stronger. suggesting that the impurity renders this silica more reactive.

  • PDF

Effect of Nano-sized Calcium-silicate-hydrate (C-S-H) Crystals on Cement Hydration (나노 크기 칼슘-실리케이트-하이드레이트(C-S-H) 결정이 시멘트 수화에 미치는 영향 분석)

  • Gyeong-Tae Kim;Su-Ji Woo;Sung-Won Yoo;Young-Cheol Choi
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.2
    • /
    • pp.153-160
    • /
    • 2023
  • In this study, nano-sized C-S-H crystals were synthesized using the liquid phase reaction method and their properties were investigated. The synthesized C-S-H crystals were added to the cement composite in suspension form to determine their effect on the hydration properties of the cement. The amount of chemical admixture was varied to obtain nano-sized C-S-H crystals with optimal agglomerated morphology, and SEM photographs were analyzed. A cleaning process was added to remove harmful substances other than the synthesiz ed C-S-H crystals. It was found that the concentration of harmful substances was reduced in the case of C-S-H crystals subjected to the cleaning process. The synthesized C-S-H suspensions were prepared with and without the cleaning process, and cement composites were prepared with the cement weight content as the main variable. The effect of C-S-H crystals on the initial hydration properties of the cement was confirmed by microhydration heat analysis. In addition, mortar specimens were prepared to measure the compressive strength over time. The test results showed that the nano-sized C-S-H crystals act as nucleation sites in the cement paste to promote the early hydration of the cement and increase the early compressive strength.

Characteristics of Water Level and Velocity Changes due to the Propagation of Bore (단파의 전파에 따른 수위 및 유속변화의 특성에 관한 연구)

  • Lee, Kwang Ho;Kim, Do Sam;Yeh, Harry
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.575-589
    • /
    • 2008
  • In the present work, we investigate the hydrodynamic behavior of a turbulent bore, such as tsunami bore and tidal bore, generated by the removal of a gate with water impounded on one side. The bore generation system is similar to that used in a general dam-break problem. In order to the numerical simulation of the formation and propagation of a bore, we consider the incompressible flows of two immiscible fluids, liquid and gas, governed by the Navier-Stokes equations. The interface tracking between two fluids is achieved by the volume-of-fluid (VOF) technique and the M-type cubic interpolated propagation (MCIP) scheme is used to solve the Navier-Stokes equations. The MCIP method is a low diffusive and stable scheme and is generally extended the original one-dimensional CIP to higher dimensions, using a fractional step technique. Further, large eddy simulation (LES) closure scheme, a cost-effective approach to turbulence simulation, is used to predict the evolution of quantities associated with turbulence. In order to verify the applicability of the developed numerical model to the bore simulation, laboratory experiments are performed in a wave tank. Comparisons are made between the numerical results by the present model and the experimental data and good agreement is achieved.

Rapid and simultaneous determination of metabolites of organic solvents in human urine by high-performance liquid chromatography using a monolithic column (Monolithic 칼럼을 이용한 뇨 중 유기용매 대사체의 신속한 HPLC 동시 분석)

  • Han, Sang Beom;Lee, Sang-Ju;Lee, Cheol-Woo;Yoon, Seo Hyun;Joung, Sun Kyung;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.433-440
    • /
    • 2006
  • A HPLC/UV method was developed and validated for the rapid and simultaneous determination of urinary metabolites of organic solvents, mandelic acid, hippuric acid, phenylglyoxylic acid, ortho-, meta- and para-methylhippuric acid, using a monolithic column. The mobile phase was composed of tetrabutylammonium bromide as ion-pairing reagent with a flow rate of 2.4 mL/min. The total run time was less than 2.5 min for all six analytes. Good linearities were obtained for all the metabolites with correlation coefficients above 0.9993. Intra-day precision, accuracy and inter-day precision was 0.01~7.32%, 83.9~116.3% and 0.01~7.16%, respectively. The method was validated and confirmed by quantification of the quality assurance samples of Industrial Safety and Health Research Institute, Korea Occupational Safety and Health Agency.

Levels of sulfonamides for animals in food (식품 중 설폰아마이드계 동물용의약품의 잔류실태)

  • Jeong, Jiyoon;Hong, Mooki;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.84-90
    • /
    • 2007
  • To determine levels of 11 sulfonamides for animals in food, simultaneously, a selective method of high performance liquid chromatography with UV detector has been applied. The targets were sulfachlorpyridazine (SCP), sulfadiazine (SDZ), sulfadimethoxine (SDM), sulfisoxazole (SSX), sulfamerazine (SMZ), sulfamethazine (SMT), sulfamethoxazole (SMX), sulfamethoxypyridazine (SMP), sulfamonomethoxine (SMM), sulfaquinoxaline (SQX) and sulfathiazole (STZ). Food samples were beef, pork, chicken, milk and whole egg that were collected at the main 6 cities in Korea as Seoul, Busan, Daejon, Incheon, Mokpo and Gangneung. After homogenizing food samples with sodium phosphate solution and acetonitrile, it was extracted with n-hexane. The mobile phase gradient was a mixture of 5 mM potassium phosphate (pH 3.25) and methanol with a gradient ratio from 100:0 to 30:70. The UV wavelength was 270 nm. The overall recoveries were ranged from 75% to 95% and the limit of detection was minimum 0.004 mg/kg for SMT, and 0.007 mg/kg for STZ at signal/noise > 3, respectively. As results, sulfonamide drugs were not detected in most of the selected food samples, however, sulfamonomethoxine was detected in meat. The determined level of sulfamonomethoxine were 0.03 and 0.06 mg/kg for beef that were below the MRLs.

Analysis of clenbuterol in bovine muscle and milk by LC-ESI/MS/MS (LC-ESI/MS/MS를 이용한 소고기와 우유에서의 클렌부테롤 분석)

  • Hong, Selyung;Jeong, Jiyoon;Park, Hyejin;Lee, Soonho;Lee, Jongok
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.535-542
    • /
    • 2008
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed for the determination and confirmation of clenbuterol in bovine muscle and milk. Clenbuterol and clenbuterol-D9 using as an internal standard in samples were extracted with ethyl acetate after hydrolysis and evaporated to dryness. The extracts were dissolved in 20% methanol and cleaned using HLB solid-phase extraction cartridge. The analytes were detected by LC-ESI/MS/MS on a $C_{18}$ column. Mass spectral acquisition was done in selected reaction monitoring (SRM) in positive ion mode to provide a high degree of sensitivity. Using MS/MS with SRM mode, the transitions (precursor to product) monitored were m/z 277${\rightarrow}$203 for clenbuterol, and m/z 286${\rightarrow}$204 for internal standard. The limits of quantitation (LOQ) and mean recoveries of clenbuterol in bovine muscle were $0.2{\mu}g/kg$ and 84.3~91.1%, respectively. The LOQ and mean recoveries in milk were $0.05{\mu}g/kg$ and 87.7~98.3%, respectively.

Biodegradation of VOC Mixtures using a Bioactive Foam Reactor I: Reactor Performance (계면활성제 미생물반응기의(혼합 VOCs) 생분해 I: 반응기 거동평가)

  • Shin, Shoung Kyu;Jang, Hyun Sup;Hwang, Sun Jin;Song, Ji Hyeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.689-694
    • /
    • 2006
  • The system performance of a bioactive foam reactor (BFR), that consists of a foam column using a surfactant and a biodegradation basin containing suspended bacteria, was investigated for the treatment of gaseous toluene or a mixture of four volatile organic compounds (VOCs, benzene, toluene, p-xylene, and styrene). Overall, the BFR achieved stable VOC removal efficiencies, indicating that it can be used as a potential alternative over conventional packed-bed biofilters. Furthermore, a dynamic loading test showed that relatively constant removal was maintained at the elevated loading due to a high mass transfer rate in the foam column. However, as the inlet concentration of VOCs increased, a portion of the VOCs mass-transferred to the liquid phase was stripped out from the biodegradation basin, resulting in a decrease in the overall removal efficiency. In the BFR, the removal efficiency of the individual VOC was mainly determined depending on the biodegradation rate (styrene > toluene > benzene > p-xylene), rather than the mass transfer rate. Consequently, increases in the microbial activity and the volume of the basin could improve the overall performance of the BFR system. Further investigation on microbial activity and community dynamics is required for the BFR when subjected to high loadings of VOC mixtures.

Research Trends on Hydrocarbon-Based Polymer Electrolyte Membranes for Direct Methanol Fuel Cell Applications (직접 메탄올 연료전지용 탄화수소계 고분자 전해질 막 연구개발 동향)

  • Yu-Gyeong Jeong;Dajeong Lee;Kihyun Kim
    • Membrane Journal
    • /
    • v.33 no.6
    • /
    • pp.325-343
    • /
    • 2023
  • Direct methanol fuel cells (DMFCs) have been attracting attention as energy conversion devices that can directly supply methanol liquid fuel without a fuel reforming process. The commercial polymer electrolyte membranes (PEMs) currently applied to DMFC are perfluorosulfonic acid ionomer-based PEMs, which exhibit high proton conductivity and physicochemical stability during the operation. However, problems such as high methanol permeability and environmental pollutants generated during decomposition require the development of PEMs for DMFCs using novel ionomers. Recently, studies have been reported to develop PEMs using hydrocarbon-based ionomers that exhibit low fuel permeability and high physicochemical stability. This review introduces the following studies on hydrocarbon-based PEMs for DMFC applications: 1) synthesis of grafting copolymers that exhibit distinct hydrophilic/hydrophobic phase-separated structure to improve both proton conductivity and methanol selectivity, 2) introduction of cross-linked structure during PEM fabrication to reduce the methanol permeability and improve dimensional stability, and 3) incorporation of organic/inorganic composites or reinforcing substrates to develop reinforced composite membranes showing improved PEM performances and durability.