• 제목/요약/키워드: liquid measurement

검색결과 1,121건 처리시간 0.026초

고효율 고체산화물 연료전지 개발을 위한 자발 착화 연소 합성법과 고상반응법에 의한 $La_ 0.7Sr_0.3MnO_3$ 양극재료 제조 및 물성에 관한 연구 (Studies on the fabrication and properties of $La_ 0.7Sr_0.3MnO_3$cathode contact prepared by glycine-nitrate process and solid state reaction method for the high efficient solid oxide fuel cells applications 0.3/Mn $O_{3}$)

  • 신웅선;박인식;김선재;박성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권2호
    • /
    • pp.141-149
    • /
    • 1997
  • L $a_{0.7}$S $r_{0.3}$Mn $O_{3}$ powders were prepared by both GNP(Glycine-Nitrate Process) and solid state reaction method in various of calcination temperature(800-1000.deg. C) and time in air. Also, L $a_{0.7}$S $r_{0.3}$Mn $O_{3}$ cathode contacts on YSZ(Yttria-Stabilized Zirconia) substrate were prepared by screen printing and sintering method as a function of sintering temperature(1100-1450.deg. C) in air. Sintering behaviors have been investigated by SEM(Scanning Electron Microscope) and porosity measurement. Compositional and structural characterization were carried out by X-ray diffractometer and ICP AES(Inductively Coupled Plasma-Atomic Emission Spectrometry) analysis. Electrical characterization was carried out by the electrical conductivity with linear 4 point probe method. As the calcination period increased in solid state reaction method, L $a_{0.7}$S $r_{0.3}$Mn $O_{3}$ phase increased. Although L $a_{0.7}$S $r_{0.3}$Mn $O_{3}$ single phase was obtained only for 48hrs at 1000.deg. C, in GNP method it was easy to get single and ultra-fine L $a_{0.7}$S $r_{0.3}$Mn $O_{3}$ powders with submicron particle size at 650.deg. C for 30min. The particle size and thickness of L $a_{0.7}$S $r_{0.3}$Mn $O_{3}$ cathode contact by solid state reaction method did not change during the heat treatment, while those by GNP method showed good sintering characteristics because initial powder size fabricated from GNP method is smaller than that fabricated from solid state reaction method. Based on enthalpy change from thermodynamic data and ICP-AES analysis, it was suggested to make cathode contact in composition of (L $a_{0.7}$S $r_{0.3}$)$_{0.91}$ Mn $O_{3}$ which have little second phase (L $a_{2}$Z $r_{2}$ $O_{7}$) for high efficient solid oxide fuel cells applications. As (L $a_{0.7}$S $r_{0.3}$)$_{0.91}$Mn $O_{3}$ cathode contact on YSZ substrate was sintering at 1250.deg. C the temperature that liquid phase sintering did not occur. It was possible to obtain proper cathode contacts with electrical conductivity of 150(S/cm) and porosity content of 30-40%.m) and porosity content of 30-40%.

  • PDF

CHARM을 이용한 작업환경측정기관 분석실의 화학물질노출 위험성 평가 연구 (Assessment of Risk of Exposure to Chemicals in the Analysis Centers of Organizations for measuring the Working Environment, using CHARM)

  • 박현아;최서연;우인성;이동호
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.660-668
    • /
    • 2017
  • 본 연구는 작업환경측정기관 분석실에서 많이 다루어지고 있는 유해화학물질에 대해 CHARM(Chemical Hazard Risk Management)을 이용한 위험성평가를 실시하고 위험성을 추정하였다. 이를 위하여 서울 및 경기지역의 위험성평가를 실시한 작업환경측정기관 6곳을 선정하였으며, 그 결과 화학물질 노출 위험성 물질은 29개 물질이 선택 되었다. 성상별로는 액체 16개, 고체 10개 물질이었고, 특별관리물질인(CMR) '발암성(Carcinogenic)' 1A - 11개, 1B - 1개, 2 - 8개, '생식세포변이 원성(Mutagenic)' 1A - 4개, 1B - 3개, 2 - 8개, '생식독성(Repro-toxic)' 1A는 해당물질이 없고, 1B - 1, 2 - 6개 물질이 포함되어 있었다. 위험성 추정 결과 '낮음'에 해당하는 물질은 30.4%, '보통' 66.1%, '높음' 3.6%로 평가 되었다. 또한 6개 기관의 각 물질별 위험성 추정 결과 2개 기관이 위험성 추정 결정 중 '높음'에 해당하는 물질을 포함하고 있었다. 본 연구를 통하여 화학물질 평가도구인 CHARM(Chemical Hazard Risk Management)을 이용한 위험성 평가를 시도하였다는데 그 의의가 있으며, 작업환경측정기관 분석실의 위험성과 관리 화학물질을 우선적으로 도출하여 안전성 평가 및 비상조치 계획 수립과 안전관리 매뉴얼 구축과 작업환경측정기관 분석실에 대한 사고 및 위험성 관리의 제도적 법적 관리의 기초 자료로 활용되기를 기대한다.

개에서 피모벤단-펜톡시필린 분말 제형 합제의 경구투여시 약물약동학 및 약물약력학에 대한 연구 (Pharmacokinetics and Pharmacodynamics Following Oral Administration of Pimobendan-Pentoxifylline Powder Formulation Mixture in Dogs)

  • 노웅빈;송두원;강여림;박유진;유초롱;이종호;김기훈;정상희;강민희
    • 한국임상수의학회지
    • /
    • 제36권1호
    • /
    • pp.46-52
    • /
    • 2019
  • Pimobendan has inotropic and vasodilating effects on cardiovascular system, and pentoxifylline is known to decrease blood viscosity and improve blood flow to the heart. This study investigated the pharmacokinetics and pharmacodynamics following oral administration of pimobendan-pentoxifylline powder mixture in dogs. Eight healthy dogs were included and were divided into control (n = 4) and experimental (n = 4) groups. Vehicle powder and pimobendan-pentoxifylline powder mixture (pimobendane 0.25 mg/kg, pentoxifylline 15 mg/kg) were administrated orally to control and experimental groups, respectively. Plasma samples and measurement of echocardiographic indices were obtained for 24 hours following administration. Pimobendan and pentoxifylline concentrations were investigated using liquid chromatography-mass spectrometer (LC-MS) assay. The elimination half-life ($T_{1/2}$) were $2.65{\pm}1.42hours$ for pimobendan and $0.29{\pm}0.23hours$ for pentoxifylline. The time to reach maximum concentration ($T_{max}$) were $1.08{\pm}0.72hours$ for pimobendan and $0.29{\pm}0.14hours$ for pentoxifylline. The maximum blood concentration ($C_{max}$) were $2.83{\pm}1.50ng/mL$ for pimobendan and $1184.33{\pm}932.37ng/mL$ for pentoxifylline. Among echocardiographic indices, fractional shortening (FS), left ventricular internal diameter at end systole (LVIDs), and pre-ejection period (PEP) showed significant changes at 1-4 hours after the administration of pimobendan-pentoxifylline powder mixture. No adverse effects were observed during the investigation. This study demonstrates that pimobendan-pentoxifylline powder mixture can be used to control cardiovascular diseases in dogs.

대체 세정제의 선정을 위한 세정성 평가방법 연구 (A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents)

  • 신진호;이재훈;배재흠;이민재;황인국
    • 청정기술
    • /
    • 제15권2호
    • /
    • pp.81-90
    • /
    • 2009
  • 본 연구에서는 산업체에서 대체 세정제를 객관적이고 체계적으로 선정하는데 도움을 주고자 여러 가지 세정성 평가방법을 실험을 통하여 비교 평가하였다. 세정성 평가방법으로는 중량법, OSEE (optically simulated electron emission)법, 접촉각법과 FTIR, UV-VIS, HPLC와 같은 정밀분석기기를 이용한 분석법을 사용하여 flux, solder, grease 등의 오염물질에 대한 세정성 평가를 수행하였다. 그 결과 중량법은 쉽고 간단하게 세정제의 세정효율을 측정할 수 있었지만 중량측정의 한계로 정밀측정이 어려웠다. 반면에 OSEE법은 세정제의 세정성 평가를 빠르고 정밀하게 수행할 수 있었다. 접촉각 측정법은 피세정물 표면에 오염물질과 세정제에 의한 얇은 친유성 막의 형성으로 인하여 접촉각 변화에 영향을 주기 때문에 세정성 평가에 특별한 주의가 요구되었다. 중량법으로 수행하기 어려운 정밀세정성 평가의 경우 UV-VIS, FTIR, HPLC와 같은 정밀분석기기를 이용하여 피세정물에 잔류한 flux, solder, grease 등의 극미량의 오염물을 특수 용제로 추출하여 아주 작은 농도의 오염물을 정량분석할 수 있었다.

LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구 (A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process)

  • 김준범;강준혁;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.

DNA 길이와 혼합 종 개수 예측을 위한 합성곱 신경망 (Convolution Neural Network for Prediction of DNA Length and Number of Species)

  • 승희;김예원;이효민
    • Korean Chemical Engineering Research
    • /
    • 제62권3호
    • /
    • pp.274-280
    • /
    • 2024
  • 기계학습법의 신경망 기술을 이용한 자료분석은 질병 유전자 탐색 및 진단, 신약 개발, 약인성 간 손상 예측 등과 같은 다양한 분야에서 활용되고 있다. 질병 특징 발견을 위한 자료분석은 DNA 정보를 기반으로 이루어질 수 있다. 본 연구에서는 DNA의 분자 정보 중 DNA의 길이와 용액 내 DNA의 길이별 종 개수를 예측하는 신경망을 개발하였다. 겔 전기영동을 통한 기존 방법론의 시간 소요 한계점을 해결하고자, 미세유체역학적 농축 장치의 동역학 자료를 분석 대상으로 하여 실험 분석 과정 중의 시간 소요 문제점을 해결하였다. 동역학 자료를 공간시간 지도로 재구성하여 학습 및 예측에 필요한 계산용량을 낮추었으며, 공간시간 지도에 대한 분석 정확도를 높이기 위해 합성곱 신경망을 활용하였다. 그 결과, 단일 변수 회귀로써의 단일 DNA 길이 예측과 복합 변수 회귀로써의 다종 DNA 길이의 동시 예측 및 이진 분류로써의 DNA 혼합 종 개수 예측을 성공적으로 수행하였다. 추가적으로, 예측 과정 중 발생할 수 있는 예측 편향을 학습 자료 구성 방식을 통한 해결책을 제시하였다. 본 연구를 활용한다면, 광학 측정 자료를 이용하는 액체생검 기반의 세포유리 DNA 분석 및 암 진단 등의 의학 자료 분석을 효과적으로 수행할 수 있을 것이다.

측정법에 따른 갑상선자극호르몬 결합억제면역글로블린(TBII)의 임상적 유용성 검토 (Clinical Usefulness of Thyrotropin Binding Inhibitor Immunoglobulin (TBII) Assay by the Comparative Method)

  • 박희원;신희정;김태훈;노경운;김현주
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.175-180
    • /
    • 2009
  • 서론 : 갑상선 기능 항진을 보이는 환자를 대상으로 항갑상선제 치료후 재발유무를 예측하거나 정확한 그레이브스병을 진단하기 위해 임상에서는 갑상선자극호르몬 결합악제면 역글로블린을 측정하는데 지금까지 1세대 liquid phase (RIA Precipitate)를 사용하였다. 그 후 예민도가 높아진 다음 세대 측정법이 다양하게 개발되었으며 실제 임상적 유용성이 보고되었다. 따라서 세대별 갑상선자극호르몬 결합억제면역글로블린 측정법 임상적 유용성 검토해 보고자 한다. 실험재료 및 방법 : 2009년 1월에서 3월까지 본원 강남건강증진센터에 내원한 환자 중 TSH, FT4, Microsome Ab 측정값이 정상범위에 드는 30명 (남자 20명, 여자 10명)을 대조군으로 하였다. 마찬가지로 2009년 1월에서 3월까지 본원 내분비내과를 내원한 환자 중 TSH<$0.05\;{\mu}IU/mL$, FT4>1.80 ng/dL인 갑상선기능항진증 진단을 받은 58명 (남자14명, 여자 44명)을 실험군으로 하였다. 측정법은 각 세대별로 1세대에서 3세대까지 각각 2가지종류의 시약을 사용하였으며, 확진 검사로 TS-Ab 검사를 실시하였다. 결과 : 대조군을 대상으로 각 세대별 측정법의 특이도를 확인하였다. (Specificity=100%, n=30) 실험군에서 민감도는 1세대 RSR<%> (79.3%, n=58), 1세대 RSR (51.7%, n=58), 2세대 RSR-CT (93.1%, n=58), 2세대 BRAHMS-CT (98.3%, n=58), 3세대 ELISA (94.6%, n=56), 3세대 ECLIA (97.7%, n=58), TS-Ab<%> (93.5%, n=46)이었다. 결론 : 갑상선자극호르몬 결합억제면역글로블린 측정법의 세대별 검토 결과 TS-Ab(%)를 확진 검사로 기준했을 때 3세대 ECLIA에 대해 2세대 BRAHMS-CT 측정법이 가장 높은 상관성을 보였다($R^2$=0.923). 따라서 기존에 사용했던 1세대 측정법을 대신하여 2세대 측정법을 사용함으로써 보다 정확하고 신속한 결과보고에 유용할 것으로 판단된다.

  • PDF

면류에서 HPLC를 이용한 데옥시니발레놀 분석법의 검증과 불확도 산정 (Single Laboratory Validation and Uncertainty Estimation of a HPLC Analysis Method for Deoxynivalenol in Noodles)

  • 옥현이;장현주;강영운;김미혜;전향숙
    • 한국식품위생안전성학회지
    • /
    • 제26권2호
    • /
    • pp.142-149
    • /
    • 2011
  • 본 연구에서는 면류에서 면역친화컬럼을 이용한 데옥시니발레놀의 HPLC분석법을 검증하고, 분석과정에서 발생될 수 있는 불확도를 GUM 지침에 따라 측정하였다. 검출한 계와 정량한계는 7.5 ${\mu}g$/kg과 18.8 ${\mu}g$/kg이었고 검량선은 20~500 ${\mu}g$/kg 농도범위 에서 0.9999의 높은 상관성을 보였다. 대표적인 밀 가공품인 건면과 라면에 데옥시니 발레놀을 200 ${\mu}g$/kg과 500 ${\mu}g$/kg을 첨가하여 회수율과 반복성올 측정한 결과, 건면에서는 $82{\pm}2.7%$$87{\pm}1.3%$의 결과를 얻었고, 라면에서는 $97{\pm}1.6%$$91{\pm}12.0%$로 측정되었다. 한편, 불확도 측정을 위한 첫 단계로, 분석과정에서의 불확도 요인은 시료량 측정, 최종 시료부피, 보관표준용액, 작업표준용액, 표준용액, 기기, 매질, 검량선 작성으로 구분하였다. 불확도 요인의 구성요인은 저울의 안정성, 분해능, 재현성, 표준물질의 순도, 분자량, 농도, 표준용액 희석, 검량선, 회수율 및 분석기기의 재현성 풍이 작용하였다. 건면과 라면에 데옥시니발레놀을 200과 500 ${\mu}g$/kg을 첨가하여 분석한 결과 건면에서는 $163.8{\pm}52.1\;{\mu}g$/kg, $435.2{\pm}91.6\;{\mu}g$/kg으로 측정되었고 라면에서는 $194.3{\pm}33.0\;{\mu}g$/kg, $453.2{\pm}91.1\;{\mu}g$/kg으로 측정되었다. 확장불확도는 합성표준불확도에 포함인자(k=2, 신뢰수준 95%)를 곱하여 산출하였다. 건면과 라면에서 데옥시니발레놀을 분석함에 있어 불확도에 영향을 주는 주요인자는 시료의 회수율과 검량선 작성인 것으로 파악되었다. 따라서 면류 시료에서 데옥시니발레놀 것으로 분석의 정밀성을 높이기 위해서는 회수율과 검량선 작성에 영향을 끼칠 수 있는 분석과정을 확인하고 오차를 최소화 할 수 있는 방안을 모색해야 할 것으로 사료된다.

만성변비환자의 방사선학적 접근방법에 관한 고찰 (Study of Radiological Approach to Treat a Chronic Constipation)

  • 윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권3호
    • /
    • pp.5-12
    • /
    • 2004
  • I. 서 론 : 변비(便秘)는 우리가 임상에서 흔히 접하는 위장관의 증상으로서, 사람들은 배변의 횟수가 너무 적거나, 대변을 힘들게 보는 경우, 대변이 너무 딱딱하거나 양이 적은 경우 혹은 배변이 너무 고통스럽거나 불완전한 배변감이 있는 경우 등과 같이 다양한 형태로서 변비라고 생각하여 병원을 찾게 된다. 그러나 변비는 식이와 사회 및 의료 환경 등의 요인에 의해 많은 영향을 받기 때문에 변비 환자의 진단 및 치료적 접근에 앞서 이러한 다양한 인자 등을 감안하여 객관적인 표준화된 정의를 설정하는데 있어 방사선학적 진단이 유용하고 이에 관한 진단적 접근방법에 대해 알아보고자 한다. II. 본 론 : 대장의 운동기능을 평가하는 검사법 가운데 가장 기본이 되는 검사가 대장통과시간(Colon transit time, CTT) 검사이다. 대장통과시간은 만성 변비증 환자의 병태생리에 따른 유형 분류와 치료 계획의 설정에 커다란 도움을 주고 있다. 방사선 비투과성 표지자(Radiopaque marker)를 이용하는 방법, 다수 표지자 사용법(Multiple marker technique), 신티그라피 측정법(Scintigraphic measurement)이 있다. 배변조영술은 항문 직장의 해부학적 정보뿐만 아니라 배변 시 항문, 직장의 변화와 골반저의 운동상태를 파악할 수 있는 기능적 방사선학 검사이다. 배변 시 항문 직장의 역동적 관찰은 배변이상 환자의 진단 및 치료방침 결정 그리고 추적검사에 도움을 준다. 마지막으로 병력에서 빠뜨려서는 안되는 것이 행동 장애나 정서 장애와 같은 정신심리학적 요인이 동반되어 있는지를 세심하게 판단하는 것이다. 이런 경우에는 이러한 정신과적 문제와 관련된 약물 복용의 유무와 종류에 대해서도 파악을 하여야 한다. III. 결 론 : 변비의 흔한 원인에는 섬유질 섭취가 충분하지 못한 경우, 수분 섭취가 충분하지 못한 경우가 많으며, 변비환자에서의 이러한 검사의 목적은 변비의 기질적 병인을 확인하기 위함으로서, 통상 이러한 방사학적 검사를 통해 결장과 항문직장의 기능에 대한 정보를 얻을 수 있는 것은 아니다. 변비 환자의 병태생리에 따른 유형을 구분하여 향후 검사 및 치료방침을 설정하는 데 중요한 정보를 제공하고 환자의 예후를 예측하는데도 도움이 될 것으로 생각된다.

  • PDF

HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정 (A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC)

  • 이홍민;곽병만;안장혁;전태홍
    • 한국식품과학회지
    • /
    • 제40권2호
    • /
    • pp.152-159
    • /
    • 2008
  • HPLC를 이용하여 조제분유 중 비타민 A 함량을 분석 할 경우 표준품 분취량 및 시료의 샘플 분취량에 따라 달라지는 불확 도 크기를 산정하기 위하여, 분석결과에 영향을 주는 여러 가지 불확도 인자를 파악하고 각각의 불확도를 계산하였다. 계산은 GUM과 Draft EURACHEM CITAC Guide에 근거한 수학적 계산 및 통계처리 방법에 의해 처리하였다. 측정 불확도의 원인으로서 측정량 계산에 사용되는 시료의 무게, 시료의 최종전량, 그리고 기기에 의한 측정결과값 등이 작용하였다. 측정 불확도 원인의 개별구성요소는 저울의 안정성, 분해능, 재현성, 표준액의 순도, 분자량, 농도, 표준액 희석, 검정선, 회수율 그리고 분석기기의 재현성 등이 작용하였으며, 반복측정된 값을 통계적인 방법에 의해 구할 수 있는 불확도는 A type, 그리고 교정성적서, 제조자의 시방서, 공개된 정보 및 상식에서 얻을 수 있는 모든 정보를 이용 하여 구할 수 있는 불확도는 B type으로 구분하여 불확도를 산정하였다. 표준품을 100 mg 계량하여 1,000 mg/L 로 제조하고 다시 적절한 농도로 희석하여 산출한 결과는 627 ${\pm}$ 33 ${\mu}$g R.E./100 g 이었고, 10 mg을 계량하여 100 mg/L 로 제조하여 산출한 경우는 627 ${\pm}$49 ${\mu}$g R.E./100 g 으로 측정 및 계산되었다. 시료량을 약 1 g, 2 g, 또는 5 g으로 차등을 준 결과 및 불확도는 각각 622 ${\pm}$ 48, 627 ${\pm}$ 33, 491 ${\pm}$ 23 ${\mu}$g R.E./100 g 으로 나타났다. 시료량이 커짐에 따라 불확도의 값이 적어지나 시료 5 g의 경우에는 결과값에 이상이 있음을 알 수 있듯이, 정확한 분석을 위해 식품공전에 명시되어 있는 시료량을 취하는 것에 주의해야 할 것이다. 비타민 A 함량 분석의 결과값에 영향을 주는 주요인자로 전처리 과정중의 검화와 액액분배 과정으로 파악되었으며, 이는 시험자의 숙련도에 따라 결과값의 편차가 발생할 수 있는 실험단계이다. 본 연구에서는, 회수율 실험의 결과와 인증표준물질의 표기값에 만족하였으므로, 검화와 액액분배에서 발생될 수 있는 오차를 최소화시킨 결과값을 도출 한 것으로 사료된다. 따라서 정확한 결과값을 도출하기위해 분석자의 숙련도 향상에 충분한 고찰이 필요할 것이다. 또한 도출된 결과값이 갖는 불확실성을 나타내는 측정불확도는 시료의 전처리 및 기기분석을 통하여 결과를 도출하는 과정 중 발생할 수 있는 모든 불확도인자를 산출하여 합성하였다. 본 연구의 결과에 의하면, 비타민 A의 정확한 분석결과를 산출하고 불확도를 최소화하기 위해 표준품은 0.1 g을 계량하여 적절한 농도로 희석 사용해야하며, 시료량은 조제분유의 경우 약 2g 정도 취하여 vitamin A를 검화하고 추출해야함을 알 수 있었다. 즉, 검화 플라스크에서 검화를 할 경우의 시료량은 vitamin A 함량에 따라 그 시료량을 달리하여 분석을 수행하여야 한다. 그리고 USP(retinyl acetate 30 mg/g) 표준품과 같이 농도가 낮은 표준품의 경우에는 최소한 0.1 g 이상을 계량하여 모용액을 제조하여 사용하여야 표준용액 제조 및 검량선에 의한 오차를 최소화할 수 있을 것으로 사료된다. 측정불확도에 대하여 시험자가 시험수행시마다 파악하고 계산하기란 시간적, 인력적 제약과 업무효율적 측면에서 현실적으로 어려운 점이 많으나, 본 연구에서와 같이 시험과정 중의 분석오차 발생인자들을 파악하고 이중 영향이 큰 주요인자들을 집중 관리하여, 그 인자들을 최소화하는 방법을 끊임없이 모색하여야 최종 시험 결과의 오차를 크게 줄일 수 있을 것으로 사료된다.