• Title/Summary/Keyword: liquid level system

Search Result 315, Processing Time 0.029 seconds

Water Rockets for Engineering Education of Launch Vehicles, Part I: Principles and System Composition (발사체 공학교육을 위한 물로켓, Part I: 원리와 시스템 구성)

  • Kim, Jae-Yeul;Hwang, Won-Sub;Choi, Jeong-Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.7
    • /
    • pp.525-534
    • /
    • 2019
  • Water rocket is a pressurized liquid propellant rocket that shares the same basic principles of space launch vehicles. Water rockets can be used as an engineering educational material for the liquid rocket principles and the launch vehicle systems, far beyond the scope of K-12 level science education. In this paper, the principles and theories of water rocket propulsion and flight dynamics was investigated at the level of undergraduate rocket engineering classes. Also, the system level design and operation of water rocket is summarized by including the components of launch vehicle, launch pad, payload and recovery as well as altitude measurement methods.

Study of Chip-level Liquid Cooling for High-heat-flux Devices (고열유속 소자를 위한 칩 레벨 액체 냉각 연구)

  • Park, Manseok;Kim, Sungdong;Kim, Sarah Eunkyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.2
    • /
    • pp.27-31
    • /
    • 2015
  • Thermal management becomes a key technology as the power density of high performance and high density devices increases. Conventional heat sink or TIM methods will be limited to resolve thermal problems of next-generation IC devices. Recently, to increase heat flux through high powered IC devices liquid cooling system has been actively studied. In this study a chip-level liquid cooling system with TSV and microchannel was fabricated on Si wafer using DRIE process and analyzed the cooling characteristics. Three different TSV shapes were fabricated and the effect of TSV shapes was analyzed. The shape of liquid flowing through microchannel was observed by fluorescence microscope. The temperature differential of liquid cooling system was measured by IR microscope from RT to $300^{\circ}C$.

Transient Analysis of Liquid Rocket Engine around the Nominal Thrust Level (정상상태 부근에서의 액체로켓 엔진의 과도해석)

  • Choi Hwan-Seok;Seol Woo-Seok;Park Soon-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.68-76
    • /
    • 2004
  • It is essential to develop a transient engine system analysis model for turbopump fed type liquid rocket engine development, especially for deriving engine system test number and conditions. In this study, we proposed a mathematical model of turbopump fed type liquid rocket engine, and inspected transient mode changes around the nominal thrust level of a rocket engine according to variations of trust control valve's opening ratio. To verify the results, we solved the same problem with AnaSyn software from Russia, and concluded that the transient code showed the similar results within $2\%$ with AnaSyn.

  • PDF

A System Analysis of the Turbopump Type Liquid Rocket Engine (터보펌프식 액체로켓엔진의 시스템 해석)

  • Lee, Jin-Kun;Kim, Jin-Han
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.5
    • /
    • pp.109-115
    • /
    • 2004
  • A 1-D system design program has been developed for the preliminary design of the turbopump system in liquid rocket engines, which use LOx and kerosene as propellants. Gasgenerator cycle and staged combustion cycle were considered as turbopump type liquid rocket engine systems. In the system analysis, mass flow balance, thrust, specific impulse, mixture ratios, turbopump power, and turbine expansion ratio of engine system were analyzed. Results show that most of the parameters agree well with real engine parameters except gasgenerator. Therefore, the l-D system design program developed in this study can be used to derive the preliminary design parameters of a turbopump with any thrust level liquid rocket engine.

Propellant utilization system on liquid-fuelled rocket (액체추진 발사체의 추진제 소진시스템)

  • Cho, Kie-Joo;Lim, Seok-Hee;Jung, Young-Suk;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.203-206
    • /
    • 2006
  • We have studied, for maximizing the total impulse of liquid propulsion system, Propellant Utilization System (PUS) to minimize outage of propellant. Propellant outage is mainly influenced by propellant mixture ratio during flight and real quantity of loaded propellant. If one employs cryogenic propellant, the variation of propellant density due to the temperature change has major effect on outage control. Feedback control of propellant level of each tank during flight could deplete both tanks simultaneously. To introduce this system, however, the mixture ratio control system of rocket engine is necessary.

  • PDF

Investigation of Validation Guidelines for Performance Verification of High Performance Liquid Chromatograph (고성능 액체크로마토그래프 기기의 성능검증을 위한 밸리데이션 가이드라인에 대한 연구)

  • Yun, Won Nam;Lee, Beom-Gyu;Lee, Wonjae
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.362-368
    • /
    • 2013
  • High performance liquid chromatograph (HPLC) is the most frequently used analytical instrument in analytical laboratories for pharmaceutical analysis. In order to provide a high level of assurance for reliable data generated from the HPLC analysis, the performance qualification of the HPLC system is required. For this purpose, the performance of HPLC system should be regularly monitored by examining the key functions of the typical HPLC system (solvent delivery system, injector system, column oven, UV-VIS detector system). We have investigated the validation guidelines of the performance verification of these key modules for HPLC system. And we proposed and evaluated its validation guidelines and the related verification methods for pharmaceutical analysis that could be practically applied in Korea.

Experimental Examination of Multivariable PID Controller Design on Frequency Domain using Liquid Level Process

  • Eguchi, Kazuki;Iwai, Zenta;Mizumoto, Ikuro;Kumon, Makoto
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.786-791
    • /
    • 2005
  • This paper is concerned with the examination and evaluation concerning a tuning method of multivariable PID controllers based on partial model matching on frequency domain proposed by authors from practical view point. In this case, PID controller parameters are determined by minimizing the loss function defined by the difference between frequency response of ideal model transfer function and actual frequency response on several frequency points. The purpose of the paper is to examine and evaluate the performance of the method through actual experiments of MIMO liquid level experimental process control equipment.

  • PDF

Liquid level control in a spherical tank by microcomputer (마이크로 컴퓨터를 이용한 구형 탱크의 액위 제어)

  • Kang, Won-Young;Oh, Min;Lee, Tae-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.459-462
    • /
    • 1986
  • The liquid level in a spherical tank was controlled with a micro-computer and the dynamic behavior of this non-linear system due to the variation of set point was studied. The adaptive control theory was used and the real values of controlled variables were compared with the theoretical values from a mathematical model.

  • PDF

The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang #3&4 and #5&6 (영광 3&4와 5&6호기에서 액체 방사성폐기물 처리방법의 비교)

  • Yeom, Yu-Seon;Kim, Soong-Pyung;Lee, Seung-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.219-230
    • /
    • 2004
  • Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontami- nation ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP #5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher radioactivity about 20% than the evaporating system, and the actual radioactivity released from the evaporating and IED system were 0.473mCi and 1.098mCi, respectively. The radioactivity released from the IED was 2.32 times higher than that of the evaporating system. The dose of off-site residents was $2.97{\times}10^{-6}$mSv for the evaporating system, and $6.47{\times}10^{-6}$mSv for IED. The decontamination factor(DF) of the evaporator is, in most cases, far lower than the lower limits of detection(LLD) with the Ge-Li detector. Due to the low concentration of the liquid wastes collected from the liquid waste system, the decontamination factor of IED is very low. Since there is not enough data on the amount of solid radioactive wastes generated by the evaporation system, the comparison on these two systems has been conducted on the basis of the design, and the comparison result was that the evaporating system generated more wastes about 40% than IED.

  • PDF

Vibration Measurements of an Intelligent Cantilever Beam in Contact with Fluid

  • Kwon, Tae-Kyu;Park, Seong-Hwa;Yu, Gye-Hyoung;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.97.3-97
    • /
    • 2002
  • This paper presents the vibration characteristics of an intelligent cantilever beam in contact with a fluid using a PZT actuator and PVDF film. The dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition in the fluid domain. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level betw...

  • PDF