• Title/Summary/Keyword: liquid flow

Search Result 2,932, Processing Time 0.031 seconds

Performance Enhancement of the Heat Pump Using the Refrigerant Subcooling System (냉매 과냉각 시스템을 이용한 열펌프의 성능향상에 관한 연구)

  • 손창효;윤찬일;박승준;이동건;오후규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.106-111
    • /
    • 2001
  • The performance characteristics of heat pump system using the new refrigerant subcooling system were investigated. The new heat pump system has the ice storage tank to accumulate the latent heat of the refrigerant during the night-time. The heat is released to subcool the saturated refrigerant liquid at the outlet of a condenser in the daytime. The experimental apparatus is a well-instrumented heat pump which consisted of a refrigerant loop and a coolant loop. The test sections(condenser and evaporator) were made of tube-in-tube heat exchanger with the horizontal copper tube of 12.7[mm] outer diameter and 9.5[mm] inner diameter. The evaporating temperatures ranged from $-5[^{\circ}C]$ to $0[^{\circ}C]$ and the subcooling degrees of the refrigerant varied from $15[^{\circ}C]$ to $25[^{\circ}C]$. The test of the ice storage was carried out at evaporating temperature of $-10[^{\circ}C]$ and the ice storage mode is an ice-on-coil type. The main results were summarized as follows ; The refrigerant mass flow rate and compressor shaft power of the heat pump system were independent of the subcooling degrees. The cooling capacity o the heat pump system increases as the evaporating temperature and subcooling degree increases. The cooling capacity of the heat pump system is about 25 to 30% higher than that of normal heat pump system. The COP of the heat pump system which subcooled the refrigerant liquid at the outlet of the condenser is about 28% higher than that of the normal heat pump system.

  • PDF

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

A Technical Review of Endothermic Fuel Use on High Speed Flight Cooling (흡열연료를 이용한 고속비행체 냉각기술 동향)

  • Kim, Joong-Yeon;Park, Sun-Hee;Chun, Byung-Hee;Kim, Sung-Hyun;Jeong, Byung-Hun;Han, Jeong-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.2
    • /
    • pp.71-79
    • /
    • 2010
  • As hypersonic flight speeds and engines efficiencies increase, heat loads on an aircraft and it's engine increase. Because the temperature of the air flow is too high to cool the aircraft structure at hypersonic flight speeds, it is essential to use the aircraft fuel as the primary coolant. Endothermic fuels are liquid hydrocarbon aircraft fuels which are able to absorb the heat loads by undergoing endothermic reactions, such as thermal and catalytic cracking. The endothermic reactions are improved by catalysts which change the extent of reaction and product distribution. At high temperature, liquid hydrocarbons would lead to coke formation that can reduce the effectiveness of heat exchanger and cause rapid degradation of the catalyst, thus endothermic capacity of endothermic fuels is limited to the temperature at which coke doesn't form. In this study, the essential cooling technologies by applying endothermic fuels and the properties of the endothermic fuels are described.

Review of Propellant Vibration and Control of Liquid Rocket Fuselage Feeding System (액체로켓 기체공급계의 추진제 진동특성 및 제어기술 동향)

  • Cho, Nam-Kyung;Kho, Hyun-Seok;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.89-94
    • /
    • 2010
  • Fuselage propellant feeding system should supply propellants to engine with required flow rate, temperature and pressure. Propellant vibration in engine and feeding line changes feeding characteristics, and frequently inhibits to satisfy the required feeding requirements. Sloshing and POGO vibration are known to be the major vibration phenomena. Concerning sloshing and POGO, vehicle control and structural dynamics aspects are extensively studied, whereas, its effect on propellant feeding performance is not clearly understood. This paper focuses on the deviation of required feeding performance due to propellant vibration. Overall characteristics of propellant vibration and its effect on propellant supply to engine are reviewed and control mechanism for suppressing vibration is introduced.

  • PDF

An Experimental Study of Discharge Coefficient with Non-Circular Effervescent Type Twin-fluid Nozzle (비원형 Effervescent Type 이유체노즐의 Discharge Coefficient에 관한 실험적 연구)

  • Lee, Sang Ji;Park, Hyung Sun;Hong, Jung Goo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.682-685
    • /
    • 2017
  • An experimental study was carried out to investigate the injection characteristics of non-circular effervescent type twin-fluid nozzles. For this purpose, two types of non-circular nozzles (E1, E2) and one kind of circular nozzle (C) were used. At this time, the Aerorator mounted on the nozzle used three different diameters to match the aspect ratio with the nozzle exit area. Therefore, experiments were performed according to three aspect ratios for each nozzle, and a total experiments were conducted. Experiments were carried out by controlling the amount of air flowing after fixing the flow rate of the liquid, and the nozzle internal pressure and SMD were measured, and the jet image was taken from the nozzle. The discharge coefficients of the three kinds of nozzles were compared with the conventional equation and the Jedelsky's equation, and the Jedelsky's equation was found to be about 4 times larger. The droplet size (SMD) injected from the nozzle was found to be smaller in the non-circular shape than in the circular shape, which is expected to be caused by the difference of the discharge coefficient values.

  • PDF

High Performance Liquid Chromatographic Analysis of a New Proton Pump Inhibitor KR60436 and Its Active Metabolite O-Demethyl-KR60436 in Rat Plasma Samples Using Column-Switching

  • Lee, Hyun-Mee;Lee, Hee-Yong;Choi, Joong-Kwon;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.207-210
    • /
    • 2001
  • A fully automated high performance liquid chromatography with column-switching was developed for the simultaneous determination of KR60436, a new reversible proton pump inhibitor, and its active metabolite O-Demethyl-KR60436 from rat plasma samples. Plasma sample (50$\mu$l) was directly introduced onto a Capcell Pak MF Ph-1 column ($10{\times}4$ mm I.D.) where primary separation was occurred to remove proteins and concentrate target Substances Using acetonitrile-Potassium Phosphate (PH 7, 0.1 M) (2 : 8, v/v). The drug molecules eluted from MF Ph-1 column were focused in an intermediate column ($10{\times}2$ I.D.) by the valve switching step. The substances enriched in intermediate column were eluted and separated on a Vydac 218MR53 column ($250{\times}3.2$ I.D.) using acetonitrilepotassium phosphate (pH 7, 0.02 M) (47:53, v/v) at a flow rate of 0.5 ml/min when the valve status was switched back to A position. The method showed excellent sensitivity (detection limit of 2 ng/ml) with small volume of samples ($50{\mu}$l), good precision and accuracy, and speed (total analysis time 24 min) without any loss in chromatographic efficiency. The response was linear ($r^2{\geq}0.797$) over the concentration range of 5-500 ng/ml.

  • PDF

Determination of Ketorolac in Human Serum by High-performance Liquid Chromatography

  • Chun, In-Koo;Kang, Hyun-Hee;Gwak, Hye-Sun
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.529-534
    • /
    • 1996
  • A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of ketorolac in human serum using a new extraction method with a good recovery. Human serum samples (1.0 ml) spiked with known concentrations of ketorolac tromethamine and 10${\mu}g$ of ketoprofen as the internal standard (IS) were acidified with 200${\mu}l$ of 1 N HCl and extracted with 7 ml of n-hexane-ether (7:3 v/v). Extracts were centrifuged and organic layer was back-extracted with 400${\mu}l$ of 0.1% tromethamine solution. Twenty .mu.l of centrifuged aqueous layer was injected onto a reversed-phase octyl column and eluted with a mixture of acetonitrile, water, methanol, and triethylamine [35:55:10:0.1 (v/v), pH 3.0] at a flow rate of 1.0 ml/min. Ultraviolet detection of ketorolac and IS was carried out at 300 nm. The calibration curve obtained using peak area ratios showed a good linearity (in concentration range 10-150 ng/ml $r^2$=O.9944; in range 50-2000 ng/ml, r$^{2}$=0.9998). The mean intra-day accuracy and precision for this HPLC method were found to be 3.6 and 3.7%, respectively. The mean inter-day accuracy and precision were found to be 4.0 and 3.7%, respectively, in the concentration range 50-2000 ng/ml. The recovery of ketorolac from serum was 92.0 $({\pm}5.7)$ % at the concentration of 100 ng/ml. This method proved to be readily applicable to the assay of ketorolac in human serum.

  • PDF

High Performance Liquid Chromatographic Assay of a New Fluoroquinolone, LB20304, in the Plasma of Rats and Dogs

  • Seo, Mi-Kyeong;Jeong, Yi-Na;Kim, Hoon-Joo;Kim, In-Chull;Lee, Yong-Hee
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.554-558
    • /
    • 1996
  • High-performance liquid chromatographic method was developed for the determination or LB 20304 (compound 1) in the plasma of rats and dogs. The analyte was deproteinized with 1 volume of methanol and 1/2 volume of 10% zinc sulfate, and the supernatant was injected onto a reversed-phase HPLC column. The mobile phase was a mixture of 24 parts of acetonitrile and 76 parts of 0.1% trifluoroacetic acid. The flow rate was 1 ml/min, and the effluent was monitored by fluorescence detector at an excitation wavelength of 337 nm and an emission wavelength of 460 nm. The retention time of compound 1 was 6.3 min. The assay of compound 1 was linear over the concentration range of 0.2-100.mu.g/ml in the plasma of rats and dogs. The lower limit of quantification was 0.2.mu.g/ml using 100.mu.l of plasma with a 97-99% accuracy and a 12-14% precision. In the 0.5, 5, and 50.mu.g/ml quality control samples, the intra- and inter-day accuracy were 88-95% and 88-97%, whereas intra- and interday precision were 0.5-6.6% and 0.2-9.3%, respectively, in the plasma of rats and dogs. The recoveries were 68-71% independent of concentration and species in the plasma. No interferences from endogenous substances were observed. Taken together, the above HPLC assay method by deproteinization and fluorescence detection was suitable for the determination of compound 1 in the preclinical pharmacokinetics.

  • PDF

Experimental Analysis of Boil-Off Gas Occurrence in Independent Liquefied Gas Storage Tank (독립형 액화가스 저장탱크의 BOG 발생에 대한 실험적 분석)

  • Cha, Seung-Joo;Bae, Jin-Ho;Lee, Dong-Ha;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.380-385
    • /
    • 2018
  • With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid state at $-163^{\circ}C$, which is a cryogenic temperature, using a liquefied gas storage tank. Accordingly, it is necessary to reduce the boil-off gas (BOG) occurrence due to the heat flow according to the temperature difference between the inside and outside of the storage tank. Therefore, in this study, a BOG measurement test on an independent-type storage tank made up of SUS304L was carried out. The test results showed the tendency for BOG occurrence according to the temperature under different filling ratios.

Study on TaeYang Type (태양형(太陽形)에 대한 연구)

  • Kim, In-Jin;Kang, Kyung-Hwa;Lee, Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.1030-1033
    • /
    • 2007
  • Following conclusions about Taeyang meridian and Taeyang type were obtained through studies with reference to the books of ${\ll}$Donguibogam${\gg}$, ${\ll}$Hwangjaenaegyung${\gg}$, and ${\ll}$Special Lectures of Master Jisan on Medical cases${\gg}$ . Park noticed that there was difference in the development of 12 meridians among the individuals and tried to apply it in the diagnosis and the treatment of the disease, thereby creating the theory of the six meridian types. The literal basis is assumed to a phrase in ${\ll}$YoungChu GyungMaek${\gg}$ , ‘人經不同 絡脈異所別也’. Taeyang meridian runs through the back of the human body. The concept of TaeYang includes surface, starting point, diffusion of Yang Gi, and emission. Small intestine meridian of hand Taeyang manages the liquid and Bladder meridian of foot Taeyang manages the muscle. There is much flow of blood and less of Gi in Taeyang meridian which makes the connection to hair, flesh, liquid, muscle and vessel. Taeyang conceals and condenses objects because it belongs to Hansu according to division of Six atmospheric influences and to the winter. The articulation is stiff and urination and elimination are abnormal when disease occurs in this meridian. The pathology of Taeyang meridian would be the invasion of outer filthy Gi affecting the Bladder meridian of foot Taeyang which then again makes Kidney meridian of foot Soeum sick. The two meridians compose the outer part and the inner part of th body. The bladder itself becomes sick sometimes. The condition of less Gi in Taeyang meridian can easily result in the shortage of Gi, and much blood makes the person to have a lofty ideal or to have capricious behavior.