• 제목/요약/키워드: liquid cell

검색결과 1,650건 처리시간 0.032초

Stability-Enhanced Liquid Crystal Mode for Flexible Display Applications

  • Jung, Jong-Wook;Jang, Se-Jin;Lee, You-Jin;Kim, Hak-Rin;Jin, Min-Young;Kim, Jae-Hoon
    • Journal of Information Display
    • /
    • 제6권2호
    • /
    • pp.1-6
    • /
    • 2005
  • We demonstrated stability-enhanced liquid crystal (LC) displays using pixel-isolated LC mode in which LC molecules are isolated in pixel by horizontal polymer layer and vertical polymer wall. The device shows good electro-optic properties against external point or bending pressure due to the polymer structures. The polymer wall acts as supporting structure from mechanical pressure and prevents the cell gap from bending. Moreover, the polymer layer acts as an adhesive to ensure a tight attachment of the two substrates. We present herein various methods for producing polymer structures by using an anisotropic phase separation from LC and polymer composites or patterned micro-structures for stable flexible liquid crystal displays.

Measurement of characteristics of plasma discharge in liquid

  • Kim, Ju-Sung;Min, Boo-Ki;Kang, Seong-Oun;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.153-153
    • /
    • 2015
  • Application of the plasma is already highlighted as a new technology in the last few years. In these days, there are lots of attempt in various application with plasma in that it is known as an effective treatment to animal, plants, material and so on. Plasma in liquid, one of new plasma applications, has advantages in ability to treat bio-cell or solutions. For example, electro-surgery, water purification, radical generation and so on. Especially, plasma discharge in solutions is very useful technique and difficult to generate due to electrolysis, vaporization and something else. In this study, we have performed plasma discharge and checked sustainability of plasma in solution(saline 0.9%). And we have measured basic characteristics of plasma in liquid. Such as electrical energy and plasma density are calculated from discharging current and voltage. Also, its thermal energy is measured with IR camera.

  • PDF

자립형 $1kW_e$ 액체 연료 개질기 운전에 관한 연구 (Experimental study on self-sustaied $1kW_e$ liquid fuel reforming operation)

  • 윤상호;배규종;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.503-506
    • /
    • 2008
  • Liquid hydrocarbon fuels, such as gasoline, kerosene, diesel and JP 8, can be good candidates for SOFC (solid oxide fuel cell) system fuel due to their high hydrogen density. Autothermal reforming (ATR) is suitable for liquid hydrocarbon fuel reforming because oxygen can decompose the aromatics in liquid fuel and steam can suppress the carbon deposition during catalytic reaction. The advantage of ATR is that it has a simple system construction due to exothermicity of ATR reaction. We control the exothermicity of reaction, make the reaction possible design a self-sustaining ATR reactor. A self-sustained 1kW-class kerosene autothermal reformer is introduced in this paper. The 1kW-class kerosene reformer was continuously operated for about 140 hours without degradation of reforming performance.

  • PDF

감온액정을 이용한 층류유동의 온도장에 관한 실험적 연구 (An Experimental Study on Laminar Flow Temperature Using Thermo-sensitive Liquid Crystal)

  • 장태현
    • 한국산업융합학회 논문집
    • /
    • 제6권4호
    • /
    • pp.373-378
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the temperature field in a two-dimensional cross section of fluid flow. This study found the temperature distribution for Re =900~1,500 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for temperature measurement and liquid crystal is used for heat transfer experiments in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

  • PDF

PEM 연료전지 유로에서 물의 거동에 대한 CFD 해석 (CFD analysis on the behavior of liquid water in flow channel of PEM fuel cell)

  • 김현일;남진현;신동훈;정태용;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.23-26
    • /
    • 2007
  • Liquid water in flow channel is an important factor that limits the steady and transient performance of PEM fuel cells. A computational fluid dynamics study based on the volume-of-fluid (VOF) multi-phase model is conducted to understand the transport behavior of liquid water in flow channel. The liquid water transport in $180^{\circ}$ bends is investigated and the effect of chamfering is discussed. The effect of wall adhesion is also considered by varying the contact angle of channel surfaces. The result of this study is believed to provide a useful guideline for design optimization of flow patterns or channel configurations of PEM fuel cells.

  • PDF

Determination of Chromium(VI) and Copper(II) in Organic Solvent - Solution by Liquid Core Optical Fiber Spectrophotometry

  • Wang, JuFang;Fen, Minzhao;Wei, Wang;He, Qushe;Wu, Guanyan
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.457-460
    • /
    • 1995
  • A new hollow fiber filled with the lower refractive index liquid as core constructs a liquid core optical fiber(LCOF). The LCOF have been used as colorimetric cell to determine elements Cr and Cu in the presence of 70%- 50% ethanol or 50% dioxane aqueous solution, based on colored complex of Chromium(VI) with Diphenycarbazid(DPC) and copper with Chromaurd S(CAS) respectively. The sensitivity (1/ng/ml) of calibration curve of Cr and Cu are 0.052, 0.017 over the range 0 - 25, 0 - 24(ng/ml) respectively. The Cr in the animal gum and Nation Standard of China are determined with recoveries of 94 - 102%.

  • PDF

감온액정을 이용한 층류유동의 속도장에 관한 실험적 연구 (An Experimental Study on Laminar Flow Velocity by Using Thermo-sensitive Liquid Crystal)

  • 장태현
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.19-24
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the velocity field in a two-dimensional cross section of fluid flow. This study found the velocity distributions for Re = 1,594 ~ 2,510 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for velocity measurement by using liquid crystal in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

  • PDF

Orientational deformation of ferroelectric liquid crystal molecules by bending performance of plastic substrate

  • Son, Ock-Soo;Lee, Ji-Hoon;Jang, Chi-Woong;Lim, Tong-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.338-341
    • /
    • 2005
  • We have examined the aspects of the orientational ordering deformation of ferroelectric liquid crystal during bending performance of plastic substrate by analyzing the polarizing optical microscope texture and the birefringence of the cell. Striped texture becomes more prominent as the radius of curvature of substrate gets smaller. The optic axis of the adjacent stripes domain was not same and the relative angle between them becomes larger as the radius of curvature gets smaller. Especially, the optic axis rotation angle of one domain was lager than the other and the liquid crystal molecules in each domain became more coherent. In addition, the birefringence data with obliquely incident light shows the polar direction shift of liquid crystal molecule by bending performance.

  • PDF

Writable Cholesteric Liquid Crystal Display and the algorithm used to detect its image

  • Lee, Da-Wei;Shiu, Jyh-Wen;Sha, Yi-An;Chang, Yu-Pei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.356-359
    • /
    • 2007
  • Writable Cholesteric Liquid Crystal Display and the algorithm used to detect its image were developed. We could use any hard tip, ex: the tip of a forefinger, to directly write an image on the surface of Cholesteric Liquid Crystal Display (CHLCD). By measuring the capacitance of one pixel of test cell (12mm x 15mm/1x1), F-state or P-state could be detected. By measuring the capacitance of one pixel of 4.1" CHLCD (241um x 241um/ 320x320), F-state or Pstate could not be detected, due to the effect of parasitic capacitance. Therefore, high frequency measurement and the algorithm were developed to detect the image on CHLCD.

  • PDF

휴대용 혈중pH 측정시스템의 구현 (Development of Portable System for Measuring pH in Blood)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF