• 제목/요약/키워드: liquid air

검색결과 1,734건 처리시간 0.032초

충돌판에 의한 원판형 분무의 공간분포에 관한 실험적 연구 (A Study on the Distribution of Cylindrical Disk Spray by a Impinging Disk)

  • 차건종;김덕줄
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.251-262
    • /
    • 1995
  • The goal of this study is to provide fundamental information on the design of a new diesel injector system. The cylindrical disk spray was made by an impinging disk insited below the exit of air-assist atomizor. The disintegration processes on a twin-fluid atomization by air-assist atomizor were investigated. Liquid jet was disintegrated at the condition that wavelength was equal and longer than the circumference of the liquid jet, .lambda. .geq. .pi.do. However, the wavelength and the diameter of the liquid jet were decreased according to the increasing of air velocity. The relative density distribution of droplets and pattern of spray by impinging disk were investigated with a C-CCD. Optimum design conditions for cylindrical disk spray were also achieved. The pattern of cylindrical spray can classified according to the size of the disk and the distance from the nozzle tip to the disk. When the space of the disk and the nozzle tip was narrow and the diameter of the disk was larger than that of the air orifice of the nozzle exit, the good distribution of spray could be achieved. When the air flowrate was constant, the spray width was decreased according to the increasing of the liquid flowrate. When the liquid flowrate was constant, the spray width was decreased according to the increasing of the air flowrate.

Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.64-69
    • /
    • 2008
  • Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.

Atomize법에 의한 용융소재의 고효율 미세화에 관한 연구(제2보 : 이젝터의 원리를 이용한 액체노즐의 액체공급 및 액막생성 기구와 특성) (A Study on the High-Efficiency Atomisation Molten Materials (PART 2 : A Study on the Mechanism of Liquid Supplying and Film Formation by Applying the Ejector Principle))

  • 오재건;조일영
    • 한국분무공학회지
    • /
    • 제3권2호
    • /
    • pp.14-23
    • /
    • 1998
  • The negative pressure as much as 10's mmHg is demanded at nozzle inside, in case of atomizing the large density molten materials. by conventional air jet nozzle. In this study, suction type fluid nozzle is designed by applying the ejector principle in order to clarify the air flow of nozzle inside, mechanism of liquid suction and liquid film formation. The results of this experimental study areas follows. Suction force of liquid is magnified by using liquid nozzle, and it is able to supply the liquid stable. Negative pressure at nozzle inside is varied by throttle angle of liquid nozzle, position and outer diameter of air jet nozzle, and have a influence on liquid suction quantity and liquid film formation.

  • PDF

액화공기(Liquid Air) 예냉기반 수소액화공정 성능 해석 및 최적화 (Performance Evaluation and Optimization of Hydrogen Liquefaction Process Using the Liquid Air for Pre-Cooling)

  • 박성호;안준건;류주열;고아름
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.490-498
    • /
    • 2019
  • The intermittent electric power supply of renewable energy can have extremely negative effect on power grid, so long-term and large-scale storage for energy released from renewable energy source is required for ensuring a stable supply of electric power. Power to gas which can convert and store the surplus electric power as hydrogen through water electrolysis is being actively studied in response to increasing supply of renewable energy. In this paper, we proposed the novel concept of hydrogen liquefaction process combined with pre-cooling process using the liquid air. It is that hydrogen converted from surplus electric power of renewable energy was liquefied through the hydrogen liquefaction process and vaporization heat of liquid hydrogen was conversely recovered to liquid air from ambient air. Moreover, Comparisons of specific energy consumption (kWh/kg) saved for using the liquid air pre-cooling was quantitatively conducted through the performance analysis. Consequently, about 12% of specific energy consumption of hydrogen liquefaction process was reduced with introducing liquid air for pre-cooling and optimal design point of helium Brayton cycle was identified by sensitivity analysis on change of compression/expansion ratio.

송풍형 로터리 버너의 특성 연구 (A study on the Characteristics of the Blowing type Rotary Burner)

  • 윤석주;최영하;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.303-306
    • /
    • 2002
  • Liquid atomization by means of a spinning cup is widely used as a device for combustion, in cooling and spray drying. In this study, the blowing type rotary atomizer was experimental carried out the investigations on the characteristics of the blowing type rotary atomizer which is an air flow energy of blower instead of an electric motor most commonly used to a driven energy. The analysis on the rotary cup speed, air velocity with the blower conditions was performed and also the drop size was measured using LDPA. It was tried to analyzed on air-nozzle size and liquid flowrate as the result. It was found that the increase of the relative velocity between liquid and air improve significantly atomization liquid, and decrease of the liquid flowrate improved the maximum drop size though the mean drop size is really the same.

  • PDF

ANALYTIC APPROACH FOR THE STUDY OF AIR AND/OR LIQUID FILLED GEOMEMBRANE TUBE SECTIONS ON A HORIZONTAL

  • Choi, Yoon-Rak
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제17권3호
    • /
    • pp.181-195
    • /
    • 2013
  • This study considers an air and liquid-filled geomembrane tube section resting on a horizontal foundation. All quantities are normalized to obtain geometrically similar solutions in the static equilibrium condition. Analytic solutions are expressed in closed form. The solution for the air or liquid-filled tube section is derived systematically as an extreme case of the air and liquid-filled tube section. The validity of these solutions is confirmed by comparing to previous study, and some results are shown for the characteristic parameters and shapes of air and/or liquid-filled cases. Using the result of present study, one can estimate the shape and characteristic parameters of a tube section without numerical integrations or iterations.

Riser의 기액유동 특성에 따른 Air-lift 펌프의 성능예측 (A Prediction of the Air-lift Pump Performance by gas-liquid Flow Charac teristics of Riser)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.252-258
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to on board ship and to raise hazardous or abrasive liquids air-lift pump provides a reliable mechanism due to its simple config-uration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newto-nian liquids. it is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates and furthermore attachment of downcomer gives little effects on riser performance the conveyed liquid flow rate increases with larger submergence rate.

  • PDF

Evaluation of Liquid Pressure Amplifier Technology

  • Reindl Douglas T.;Hong Hiki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권3호
    • /
    • pp.119-127
    • /
    • 2005
  • Liquid pressure amplifiers have been proposed as an energy saving technology for vapor compression refrigeration systems configured with direct-expansion evaporators. The technology utilizes a refrigerant pump in the high pressure liquid line as a means of maintaining a suitable pressure differential across the expansion valve while lowering condensing pressure to achieve the reduction of compressor energy consumption. Applications have been proposed on systems ranging from small unitary air-conditioning to large supermarket and commercial refrigeration systems. This paper clarifies the role of such a device in a vapor compression refrigeration system. Limitations are presented and discussed. Finally, results of detailed analyses are presented to quantify the energy consumption both with and without a liquid pressure amplifier in a unitary air conditioning system. The estimated energy savings associated with the installation of a liquid pressure amplifier are minimal.

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

평행공기류에 의한 액막류 표면파의 분열기구에 관한 실험적 연구 (An experimental study on mechanism for the disintegration of liquid film surface waves by a parallel air flow)

  • 이규영;양옥용
    • 오토저널
    • /
    • 제14권6호
    • /
    • pp.81-90
    • /
    • 1992
  • This paper deals with an experimental study on the initial condition of liquid film surface waves disintegration and investigation on the behavior of liquid film surface waves formed by the high speed air flow on the solid plane surface. The authors conducted the qualitative and quantitative study to in vestigate the liquid film flow phenomena, the liquid film disintegration mechanism, and droplet formation process with breaking the liquid film surface wave. The newly devised transparent rectangular test section which has semi-two-dimensional flow at the center of the bottom was introduced to perform the experimental study, and it can generate the uniform thickness liquid film at the bottom. The strobo streak camera was used to obtain the instantaneously transformed photographs. The electronic measuring device was also used to measure the liquid film thickness variation in order to perform the easy and effective analysis of complex flow phenomena in the air-water cocurrent flow.

  • PDF