• Title/Summary/Keyword: liquid absorption

Search Result 539, Processing Time 0.023 seconds

Study on Absorption Characteristics of $CO_2$ in Aqueous Alkanolamine Solutions (알카놀아민 수용액을 이용한 이산화탄소 흡수특성 연구)

  • Oh, Sang-Kyo;Rhee, Young-Woo;Nam, Sung-Chan;Yoon, Yeo-Il;Kim, Young-Eun
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.241-246
    • /
    • 2008
  • Increase of $CO_2$ by using fossil fuels makes mainly global warming and the international efforts to reduce the $CO_2$ emission is being promoted. Absorption process using aqueous alkanolamine solution to remove acid components in the mixed gases has been used commercially. This method was used to remove $CO_2$ in the flue gas in recent years. $CO_2$ Absorption characteristics of several aqueous alkanolamine solutions such as MEA, DEA and AMP was studied by measuring vapor-liquid-equilibrium(VLE) and absorption velocity in this study. VLE measuring equipment, shell and reactor type, was used to acquire VLE data, equilibrium $CO_2$ pressure(${P_{CO_2}}^*$) and time at each pulse gas input. We also acquired the $CO_2$ absorption velocity by measuring the time to arrive the VLE at $40{\sim}80^{\circ}C$ and first gas input. The $CO_2$ absorption capacity of MEA 10wt% solution was higher than two alkanolamine solutions at $40^{\circ}C$ and the equilibrium $CO_2$ loading was 0.5. Absorption capacity was excellent as follows; AMP>DEA>MEA. But absorption velocity was fast as follows; MEA>AMP>DEA. Though good absorbent was considered by many variables, absorption velocity and capacity was more important factor.

The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application (방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가)

  • Shin, Jung-Wook;Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Yul;Kim, Jin-Young;Lee, Gun-Hwan;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

Preparation of Temazepam Soft Elastic Gelatin Capsule (Softgel) and Bioavailability in Rabbits (테마제팜 연질캅셀제의 제조와 가토에 있어서 생체이용율)

  • Park, Gee-Bae;Jung, Eui-Cha;Cho, Jung-Ki;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.49-54
    • /
    • 1992
  • This study was carried out for the purpose of developing an effective temazepam soft elastic gelatin capsule (softgel) which exhibits an excellent bioavailability and of comparing the rate and extent of absorption of temazepam from the marked elixir and prepared softgel using hydrophilic liquid such as polyethylene glycol 400 as a suspending agent by rotary die method. Both softgel and elixir containing 3 mg of temazepam were given to 7 healthy male New Zealand White rabbits in a single oral dose cross-over study. Plasma temazepam concentrations were measured by HPLC. The mean peak concentrations of temazepam following a single oral dosing as softgel and elixir dosage form were 13.84 and 13.25 ng/ml, respectively. And the mean time to peak concentration was 1.29 hr for the softgel and 1.07 hr for the elixir. There was no significant difference in the extent of drug absorption (AUC) for the two different dosage froms (p>0.05). While the softgel exhibited mean lag time of 0.63 hr, the elixir did not show any lag time. Statistical moment parameters such as the mean residence time and variance of the mean residence time did not differ significantly for the two formulations.

  • PDF

Effect of High Solid Coating and Water Absorption Uniformity of Base Paper on Print Mottle - Evaluation of print mottle with PEA module - (고농도 도공과 원지의 흡수특성이 인쇄모틀에 미치는 영향 - PEA Module를 이용한 인쇄모틀 평가 -)

  • Yoo, Sung-Jong;Cho, Byoung-Uk;Kim, Yong-Sik;Lee, Yong-Kyu;Lee, Se-Hyun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.2 s.120
    • /
    • pp.17-24
    • /
    • 2007
  • PEA(Print Evenness Analyzer) Module can be utilized as a tool to evaluate print mottle. The tester is de-signed to measure the uniformity of liquid penetration into paper at very short contact time. To evaluate effects of base paper properties on print mottle, the experiments were performed with 3 types of base pa-per whose sizing degree, roughness and porosity were varied. Coated papers were produced with high solid coating color (70%) and low solid coating color (67%). Uniformity of water absorption into base paper and coated paper was measured with PEA. It was found that, in order to minimize print mottle, base paper shall be produced with a high sizing degree and low roughness and the concentration of coating color shall be kept as high as possible, providing that it has proper rheology properties for coating process.

Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor (실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구)

  • 동종인;구우회;임대현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.

A study on the Band Gap Energy Measurement of Liquid Phase Photocatalytic Sols (액상 광촉매 졸의 밴드갭 에너지 측정 연구)

  • Yoon, Cho-Rong;Qamar, Mohamad;Oh, Hyo-Jin;Hwang, Jong-Seon;Kim, Sun-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.39-42
    • /
    • 2006
  • Titania sols or powders were are very promising materials for environment as photocatalyst. The band gap energy of $TiO_2$ has been known to be 2.8 to 3.2 eV. But the measuring system of its band gap is usually depend on absorption properties. Thus, in this study, absorption properties of $TiO_2$ sols prepared by hydrothermal process were researched with the effect of various particle sizes and concentrations. The mean particle size in $TiO_2$ sols increased as 15 nm to 60 nm, absorption graph measured by UV-Vis spectrometer shows to move red-shift. When dilute solution added with $2^n$ in $TiO_2$, the band gap energy increases as linear function.

  • PDF

Microstructure and mechanical properties of ternary pastes activated with multi-colors glass and brick wastes

  • I.Y. Omri;N. Tebbal;Z. Rahmouni
    • Advances in concrete construction
    • /
    • v.17 no.3
    • /
    • pp.167-177
    • /
    • 2024
  • Disposal of waste glass derived from bottle or packaging glass, flat glass, domestic glass is one of the major environmental defies. Moreover, the remnants of bricks resulting from the remnants of buildings are also considered an important factor in polluting the environment due to the difficulty of filling or getting rid it. The aim of this study is to valorize these wastes through chemical activation to be an environmentally friendly material. The Microstructure, compressive strength, setting time, drying shrinkage, water absorption of different pastes produced by clear glass (CG), green glass (GG) and brick waste (BP) activated were tested and recorded after curing for 3, 7, 28 and 365 days. Five samples of pastes were mixed in proportions represented by: 100% GP (GP), 100% GGP (GGP), 100% BP (BP), 90% GP + 10% BP (GPB) and 90% GGP + 10% BP (GGPB). Various parameters considered in this study include sodium hydroxide concentrations (10 mol/l); 0.4 as alkaline liquid to binder ratio; 2.5 as sodium silicate to sodium hydroxide ratio and cured at 60℃ for 24 hours. Experimental results revealed that the addition of 10% of BP resulted in an increased strength performance of geopolymer paste especially with GGPB compared to GGP in 365 days. In addition, the 10% amount of BP increases the absorption and shrinkage rate of geopolymer pastes (GPB and GGPB) by reducing the setting time. SEM results revealed that the addition of BP and GP resulted in a dense structure.

Effects of Non-Absorbable Gases on the Absorption Process of Aqueous LiBr Solution Film in a Vertical Tube (I) (수직관내 리튬브로마이드 수용액막의 흡수과정에 대한 비흡수가스의 영향)

  • Kim, Byeong-Ju;Lee, Chan-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.489-498
    • /
    • 1998
  • Among the heat/mass exchange units composing an absorption system, the absorber, where the refrigerant vapor is absorbed into the liquid solution is the one least understood. In the present study, the effects of non-absorbable gas on the absorption process of aqueous lithium bromide solution falling film inside a vertical tube were experimentally investigated. In the range of film Reynolds number of 30 ~ 195, heat and mass transfer characteristics were investigated as a function of non-absorbable gas volumetric concentration, 0.2 ~ 20%. An increase of non-absorbable gas volumetric concentration degraded the mass transfer rate dramatically in the absorption process. The reduction of mass transfer rate was significant for the addition of small amount of non-absorbable gas to the pure vapor. At film Reynolds number of 130, an increase of non-absorbable gas concentration from 0.2 to 6.0% resulted in the decrease of mass transfer rate by 36% and 20% of non-absorbable gas by 59%. However the decrease of film Nusselt number with the increase of volumetric concentration of non absorbable gas was relatively smaller than the decrease of Sherwood number. Critical film Reynolds number was identified to exist for the maximum heat and mass transfer regardless of the volumetric concentration of non-absorbable gases.

A Comparison of the Intestinal Absorption of Amino Acids in Piglets When Provided in Free Form or as a Dipeptide

  • Li, Defa;Zhao, X.H.;Yang, T.B.;Johnson, E.W.;Thacker, P.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.939-943
    • /
    • 1999
  • Three 28 day-old $Duroc{\times}Large$ $White{\times}Landrace$ litter mate gilts weighing an average of 6.5 kg were used to study the intestinal absorption of amino acids when provided in dipeptide form or in the form of a free amino acid mixture. The pigs were given one of three treatments. The control involved a duodenal infusion containing no amino-acids (phosphate buffer plus 5% sorbitol) while the remaining two treatments involved either a duodenal infusion containing a glycine-lysine dipeptide (1 g) or a mixture of the free amino acids glycine and lysine at the same concentration as in the dipeptide. Blood was drawn from a cannula inserted in the portal vein, at 5 to 20 minute intervals, for two hours following infusion. The concentration of intact dipeptide as well as free glycine and lysine in the portal blood was determined by high performance liquid chromatography. The intact dipeptide was never detected in the portal blood at any time after infusion. Lysine appeared in the portal blood more rapidly after infusion of dipeptide than after infusion of free lysine and the concentration of lysine in portal blood was higher in the pig infused with the dipeptide than after infusion of free lysine at almost all time points measured. The cumulative absorption of lysine and glycine from the intestine during the two hour period after infusion was greater in the pig infused with dipeptide than in the pig infused with free amino acids. The results suggest that although intact dipeptide did not reach he portal circulation, a special transport mechanism for absorption of dipeptide by intestinal cells appears to be present in pigs similar to that observed in other species.