• Title/Summary/Keyword: linked treatment process

Search Result 63, Processing Time 0.035 seconds

Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant (하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.52-59
    • /
    • 2012
  • As the result of reviewing the linked treatment of water quality for treating process at public livestock wastewater treatment facilities for fair selection of the proper linked process in case of linking sewage treatment plant for livestock wastewater, in case of wastewater processed by bio-reactor that is only biologically-treated, the load factor showed relatively high as 1.67%(base on design quality), 2.59%(base on operation quality) regarding COD and 3.69%(base on design quality), 7.67%(base on operation quality) regarding $COD_{Mn}$ but it is judged that there is nearly no influence on the operation of sewage treatment plan. And, in case of oxidized flotation-treated water & biofiltlation-treated water that are the advanced wastewater treatment, the load factor is approximately 1% and there is concern about the installation of excessive facilities in case of installing the advanced wastewater treatment. So, in case of considering the economic efficiency & stable operation of sewage treatment plant S, it is judged to be desirable to link with wastewater processed by bio-reactor that is biologically-treated.

Improving the Reactivity and Harmlessness of Recalcitrant Contaminants by Reduction-oxidation-linked Process (환원-산화 연계처리를 통한 니트로벤젠의 반응성 향상 및 무해화 연구)

  • Kwon, Hee-Won;Hwang, Inseong;Kim, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1205-1211
    • /
    • 2020
  • In this study, the applicability of reduction-oxidation-linked treatment was evaluated for nitrobenzene and a by-product by analyzing the reaction kinetics. Nitrobenzene showed very low reactivity to persulfate that was activated using various methods. Nitrobenzene effectively reacted through the reduction process using Zero-Valent Iron (ZVI). However, aniline, a toxic substance, was produced as a by-product. Reduction-oxidation-linked treatment is a method that can allow the oxidative degradation of aniline after reducing nitrobenzene to aniline. The experimental results show improved reactivity and complete decomposition of the by-product. Improved reactivity and decomposition of the by-product were observed even under conditions in which the reduction-oxidation reaction was induced simultaneously. No activator was injected for persulfate activation in the process of reducing oxidant linkage, and the activation reaction was induced by ferrous iron eluted from the ZVI. This indicates that this method can be implemented relatively simply.

A Study on the Effect of Chemical Pretreatment for Livestock Wastewater on the Linked Treatment of Sewage (축산폐수 처리 시 화학적 전처리가 연계처리에 미치는 영향 연구)

  • Han, Jun-Suk;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.89-97
    • /
    • 2010
  • In this study, to investigate the effect of chemical pretreatment for livestock wastewater, laboratory scale test for ozonation and linked treatment of sewage were conducted. and the results were obtained as follows. The ozonation of livestock wastewater showed the COD removal rate per hour to be 17%, 78% and 62% at each pH 4, 7 and 10, respectively. With transformation of NBDCOD to biodegradable BDCOD by ozonation, the ratio of SCODcr/TCODcr was increased from 26% to 38%. Accordingly, pretreatment of livestock wastewater affected to the biological post treatment process to elevate removal efficiency by transformation of nonbiodegradable mass to biodegradable mass. As the results of linked treatment of pre-ozonated livestock wastewater and sewage in the MLE process, the treatment efficiencies of TCODcr 93.8%, T-N 74.3%, T-P 89.7%, SS 97.5% were earned at 100% of internal recycle rate. When the internal recycle rate was increased to 150%, the treatment efficiencies of TCODcr 94.5%, T-N 54.5%, T-P 70.8%, SS 98.5% were earned. Also the removal efficiencies of TCODcr 92.6%, T-N 83.1%, T-P 81.9%, SS 98.5% were earned as the internal recycle rate was increased to 200%. Especially, nitrogen removal efficiency in the linked treatment showed 74.3%, 54.5%, 83.1% at 100%, 150% and 200% of internal recycle ratio, respectively, which revealed the tendency of higher removal efficiency than that of sewage treatment.

Improvement of treatment efficiency for sanitary treatment facilities by process modifications (분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구)

  • Lee, Chan Won;Kim, Seung Hyeon;Kim, Chang Su;Mun, Seong Won;Jeon, Hong Pyo;Yun, Jong Seop
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

Overview of Risk-Sharing Schemes: Focusing on Anticancer Drugs (위험분담제도에 대한 고찰: 항암제 사례를 중심으로)

  • Sohn, Hyun Soon;Shin, Hyun Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.23 no.2
    • /
    • pp.89-96
    • /
    • 2013
  • This article aimed to introduce 'risk sharing' schemes for pharmaceuticals between drug manufacturers and healthcare payer. Published literature review was undertaken to summarize risk sharing concepts and collect information on existing scheme examples in other countries focusing on new anticancer drugs. Risk sharing schemes could be categorized into health outcomes-based and non-outcomes (financial) based ones. Outcome-based schemes could be broken down into performance-linked reimbursement and conditional coverage. Performance-linked reimbursement can be further broken into outcomes guarantee and pattern or process of care and conditional coverage included coverage with evidence development and conditional treatment continuation schemes. Non-outcome based schemes included market share and price volume at population level, and utilization caps and manufacturer funded treatment initiation at patient level. We reviewed the fifteen examples for anticancer drugs that risk sharing agreements in response to the inherent uncertainties and increased costs of eleven anticancer drugs. Of them, eight cases were coverage with evidence development schemes. The anticancer drugs except bevacizumab and cetuximab were all listed on the national health insurance formulary in Korea, with reimbursement criteria defined on the basis of approved indications and administrations. Risk sharing approach may be a useful tool to ensure values for drug expenditure, but there are a number of concerns such as high administration costs, lack of transparency and conflicts of interest, especially for performance-based health outcomes reimbursement schemes.

Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater (소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선)

  • Jaiyeop Lee;Jesmin Akter;Ilho Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

The Effects of Oxygen Plasma and Cross-link Process on Quantum-dot Light Emitting Diodes

  • Cho, Nam-Kwang;Kang, Seong Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.215-215
    • /
    • 2014
  • Red color light emitting diodes (LEDs) were fabricated using CdSe/CdZnS quantum dots (QDs). During the device fabrication process, oxygen plasma treatment on the ITO surface was performed to improve the interfacial contact between ITO anode and the hole injection layer. CdSe/CdZnS quantum dots were cross-linked to remove their surrounded organic surfactants. The device shows red emission at 622 nm, which is consistent with the dimension of the QDs (band gap=1.99 eV). The luminance shows 6026% improvement compared with that of LEDs fabricated without oxygen plasma treatment and quantum dots cross-linking process. This approach would be useful for the fabrication of high-performance QLEDs with ITO electrode and PEDOT:PSS hole injection layers.

  • PDF

Evaluation of the Estrogenic Activity by Yeast Two-hybrid Assay and Enzyme-linked Immunosorbent Assay in Sewage Treatment Plant (하수처리장의 내분비계장애물질에 대한 Yeast Two-hybrid Assay와 Enzyme-linked Immunosorbent Assay에 의한 에스트로겐활성도 평가)

  • Lee, Byoung-Cheun;Ra, Jin-Sung;Kim, Sang-Don;Kawai, Hukiko;Lee, Chul-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.771-777
    • /
    • 2007
  • Several endocrine disrupting chemicals(EDCs) were monitored to evaluate the estrogenic activities and the concentrations by yeast two-hybrid assay and enzyme-linked immunosorbent assay(ELISA) in sewage treatment plant(STP) which consist of industrial and domestic line. In the influent of domestic line, estrone, 17$\beta$-estradiol, 17$\alpha$-ethinylestradiol and alkylphenolethoxylate(APE) were detected up to 167.1, 39.7, 7.3 and 145.4 ng/L, respectively. The average removal efficiency of 17$\beta$-estradiol after the activated sludge process was 77.5% and further removed to 80.8% after the sand filtration-ozonation step. These results suggests that the activated sludge process has limited potential to remove the estrogenic activity effectively. The contributions of the estrogenic chemicals to the estrogenic activities were 70.7, 23.3, 3.7 and 2.3% for estrone, 17$\beta$-estradiol 17$\alpha$-ethinylestradiol and APE, respectively, in the domestic line effluents. Therefore, 17$\beta$-estradiol and estrone contributed most of the estrogenic activity in the domestic line effluents.

Fabrication of Cross-linked Nano-Fibrous Chitosan Membranes and Their Biocompatibility Evaluation

  • Nguyen, Thi-Hiep;Lee, Seong-Jin;Min, Young-Ki;Lee, Byong-Taek
    • Korean Journal of Materials Research
    • /
    • v.21 no.2
    • /
    • pp.125-132
    • /
    • 2011
  • Fibrous chitosan membranes were fabricated as a substrate for skin applications using an electro-spinning process with different solvents and varying concentrations. Scanning electron microscopy (SEM) images confirmed that the formation of the chitosan fibrous membrane in trifluoroacetic acid was better than that in acetic acid. Fourier transform infrared spectroscopy showed that the chitosan fibers were cross-linked with glutaraldehyde, and that the cytotoxicity of the aldehyde groups was reduced by glycine and washing by NaOH and DI water. Chitosan cross-linked fibrous membranes were insoluble in water and could be washed thoroughly to wash away glycine and excess NaOH and prevent the infiltration of other water soluble bio-toxic agents using DI water. MTT assay method was employed to test the cytotoxicity of chitosan membranes during fabricating, treating and washing processes. After the dehydration of cell cultured chitosan membranes, cell attachment behavior on the material was evaluated using SEM method. Effect of the treatment processes on the biocompatibility of the chitosan membranes was shown by comparing of filopodium and lamellipodium of fibroblast cells on grown washed and unwashed chitosan fibrous membrane. The MTT assay and SEM morphology confirmed that the washed chitosan fibrous membrane increased cell attachment and cell growth, and decreased toxicity compared to results for the unwashed chitosan fibrous membrane.

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.