• Title/Summary/Keyword: linearity analysis

Search Result 1,164, Processing Time 0.024 seconds

Analysis of impact response and damage in laminated composite cylindrical shells undergoing large deformations

  • Kumar, Surendra
    • Structural Engineering and Mechanics
    • /
    • v.35 no.3
    • /
    • pp.349-364
    • /
    • 2010
  • The impact behaviour and the impact-induced damage in laminated composite cylindrical shell subjected to transverse impact by a foreign object are studied using three-dimensional non-linear transient dynamic finite element formulation. A layered version of 20 noded hexahedral element incorporating geometrical non-linearity is developed based on total Langragian approach. Non-linear system of equations resulting from non-linear strain displacement relation and non-linear contact loading are solved using Newton-Raphson incremental-iterative method. Some example problems of graphite/epoxy cylindrical shell panels are considered with variation of impactor and laminate parameters and influence of geometrical non-linear effect on the impact response and the resulting damage is investigated.

Analysis of Ginsenosides by Thermospray LC/MS (열분무 LC/MS에 의한 인삼사포닌의 분석)

  • Park, Man-Ki;Park, Jeong-Hill;Hwang, Gwi-Seo;Lee, Mi-Young;Park, In-Jeong
    • Journal of Ginseng Research
    • /
    • v.19 no.2
    • /
    • pp.134-137
    • /
    • 1995
  • Ginseng saponins were analyzed by thermospray (TSP) LCMS method using ODS column and with acetonitrile/ammonium acetate solution. Optimal condition for TSP Lchfs was found as follows: capillary temperature: 33$0^{\circ}C$ repelled voltage: 200 V, and concentration of ammonium acetate: 0. 05 M. Panaxadiol and panaxatriol type saponins showed characteristic fragment ions. The calibration curve of ginseng saponin showed good linearity with a correlation coefficient of 0.99. Detection limits using selected ion monitoring (SIM) technique were improved by 10~200 times compared to conventional HPLCnnr detection method.

  • PDF

Miniaturized Fluorometer Based on Total Internal Reflector and Condensing Mirror

  • Jang, Dae-Ho;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.81-85
    • /
    • 2013
  • A miniaturized fluorescence detection system based on total internal reflection (TIR) configuration, which is applicable to detecting the presence of biological materials labeled with fluorescence dye in micro total analysis systems (${\mu}TAS$), is proposed. In conventional fluorescence testing and analysis devices, interference between the excitation light beam and the emitted light from dyes is unavoidable. This paper presents a fluorescence detection system based on TIR configuration that allows the excitation light beam and the emitted light to be spatially perpendicular to each other so as to minimize the interference where fluorescence emission is detected at the orthogonal angle to the excitation beam. We achieved the limit of detection of about 5 nmol/L with a high linearity of 0.994 over a wide range of 6-FAM mol concentration, being comparable to that in earlier studies.

Nonlinear thermal displacements of laminated composite beams

  • Akbas, Seref D.
    • Coupled systems mechanics
    • /
    • v.7 no.6
    • /
    • pp.691-705
    • /
    • 2018
  • In this paper, nonlinear displacements of laminated composite beams are investigated under non-uniform temperature rising with temperature dependent physical properties. Total Lagrangian approach is used in conjunction with the Timoshenko beam theory for nonlinear kinematic model. Material properties of the laminated composite beam are temperature dependent. In the solution of the nonlinear problem, incremental displacement-based finite element method is used with Newton-Raphson iteration method. The distinctive feature of this study is nonlinear thermal analysis of Timoshenko Laminated beams full geometric non-linearity and by using finite element method. In this study, the differences between temperature dependent and independent physical properties are investigated for laminated composite beams for nonlinear case. Effects of fiber orientation angles, the stacking sequence of laminates and temperature on the nonlinear displacements are examined and discussed in detail.

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.

An Empirical Study on Dimension Reduction

  • Suh, Changhee;Lee, Hakbae
    • Journal of the Korean Data Analysis Society
    • /
    • v.20 no.6
    • /
    • pp.2733-2746
    • /
    • 2018
  • The two inverse regression estimation methods, SIR and SAVE to estimate the central space are computationally easy and are widely used. However, SIR and SAVE may have poor performance in finite samples and need strong assumptions (linearity and/or constant covariance conditions) on predictors. The two non-parametric estimation methods, MAVE and dMAVE have much better performance for finite samples than SIR and SAVE. MAVE and dMAVE need no strong requirements on predictors or on the response variable. MAVE is focused on estimating the central mean subspace, but dMAVE is to estimate the central space. This paper explores and compares four methods to explain the dimension reduction. Each algorithm of these four methods is reviewed. Empirical study for simulated data shows that MAVE and dMAVE has relatively better performance than SIR and SAVE, regardless of not only different models but also different distributional assumptions of predictors. However, real data example with the binary response demonstrates that SAVE is better than other methods.

Voltammetry of Constant Phase Elements: Analyzing Scan Rate Effects

  • Hyeonsu Je;Kwok-Fan Chow;Byoung-Yong Chang
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.427-435
    • /
    • 2024
  • Here we introduce a new method for characterizing the constant phase element (CPE) in electrochemical systems using cyclic voltammetry (CV), presenting an alternative to the conventional electrochemical impedance spectroscopy (EIS) approach. While CV is recognized for its diagnostic capabilities in electrochemical analysis, it traditionally encounters difficulties in accurately measuring CPE systems due to a lack of clear linearity with scan rates, unlike capacitors. Our research demonstrates a linear relationship between current and scan rate on a log-log plot, enabling the calculation of n and Y0 values for CPE from the slopes of these linear relationships. For validation of our method, it is applied to two kinds of capacitors and the results agree with those measured by EIS. Although EIS is known to be accurate in measuring CPE systems, our alternative approach offers a timely and reasonably precise diagnostic tool, balancing between ease of use and accuracy, especially beneficial for preliminary assessments before conducting further in-depth analysis.

Optimization of Analytical Method for Annatto Pigment in Foods (식품 중 안나토색소 분석법 최적화 연구)

  • Lee, Jiyeon;Park, Juhee;Lee, Jihyun;Suh, Hee-Jae;Lee, Chan
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.4
    • /
    • pp.298-309
    • /
    • 2021
  • In this study we sought to develop a simultaneous analysis method for cis-bixin and cis-norbixin, the main components, to detect annatto pigment in food. To establish the optimal test method, the HPLC analysis methods of the European Food Safety Authority (EFSA), Japan's Ministry of Health, Labor and Welfare (MHLW), and National Institute of Food and Drug Safety Evaluation (NIFDS) were compared and reviewed. In addition, a new pretreatment method applicable to various foods was developed after selecting conditions for simultaneous high-performance liquid chromatography (HPLC) analysis in consideration of linearity, limit of detection (LOD), limit of quantification (LOQ), and analysis time. The HPLC analysis method of NIFDS showed the best linearity (R2 ≥ 0.999), exhibiting low detection and quantification limits for cis-norbixin and cis-bixin as 0.03, 0.05 ㎍/mL, and 0.097, 0.16 ㎍/mL, respectively. All previously reported pretreatment methods had limitations in various food applications. However, the new pretreatment method showed a high recovery rate for all three main food groups of fish meat and meat products, processed cheese and beverages. This method showed an excellent simultaneous recovery rate of 98% or more for cis-bixin and cis-norbixin. The HPLC analysis method with a new pretreatment method showed high linearity with a coefficient of determination (R2) of 1 for both substances, and the accuracy (recovery rate) and precision (%RSD) were 98% and between 0.4-7.9, respectively. From this result, the optimized analytical method was considered to be very suitable for the simultaneous analysis of cis-bixin and cis-norbixin, two main components of annatto pigment in food.

Efficient non-linear analysis and optimal design of biomechanical systems

  • Shojaei, I.;Kaveh, A.;Rahami, H.;Bazrgari, B.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.4
    • /
    • pp.207-223
    • /
    • 2015
  • In this paper a method for simultaneous swift non-linear analysis and optimal design/posture of mechanical/biomechanical systems is presented. The method is developed to get advantages of iterations in non-linear analysis and/or generations in genetic algorithm (GA) for the purpose of efficient analysis within the optimal design/posture. The method is applicable for both size and geometry optimizations wherein material and geometry non-linearity are present. In addition to established mechanical systems, the method can solve biomechanical models of human musculoskeletal system. Optimization-based procedures are popular methods for resolving the redundancy at joints wherein the number of unknown muscle forces is far more than the number of equilibrium equations. These procedures involve optimization of a cost function(s) which is assumed to be consistent with the central nervous system's strategy when activating muscles to assure equilibrium. However, because of the complexity of biomechanical problems (i.e., due to non-linear biomaterial, large deformation, redundancy of the problem and so on) efficient analysis are required within optimization procedures as suggested in this paper.

Development of Geometrically Nonlinear Finite Element Analysis Examples for Computational Structural Analysis (전산구조해석을 위한 기하학적 비선형 유한요소해석 예제 개발)

  • Na, Won-Bae;Lee, Sun-Min
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.24 no.5
    • /
    • pp.699-711
    • /
    • 2012
  • An undergraduate course named computational structural analysis becomes more significant in recent years because of its important role in industries and the recent innovation in computer technology. Typically, the course consists of introduction to finite element method, utilization of general purpose finite element software, and examples focusing on static and linear analyses on various structural members such as a beam, truss, frame, arch, and cable. However, in addition to the static and linear analyses, current industries ask graduates to acquire basic knowledge on structural dynamics and nonlinear analysis, which are not listed in the conventional syllabus of the computational structural analysis. Therefore, this study develops geometrically nonlinear examples, which can help students to easily capture the fundamental nonlinear theory, software manipulation, and problem solving skills. For the purpose, five different examples are found, developed for the analyses of cables and cable nets, which naturally have strong geometrical non-linearity. In the paper, these examples are presented, discussed, and finally compared for a better subject development.