• 제목/요약/키워드: linear-board

검색결과 221건 처리시간 0.036초

제주-대한해협 해역에서 에어로졸의 화학적 특성과 침적 (Chemical Characteristics and Deposition of Aerosols in the Cheju-Korea Straits)

  • 김석현;이현미;문덕수
    • Ocean and Polar Research
    • /
    • 제44권4호
    • /
    • pp.297-310
    • /
    • 2022
  • To understand the chemical composition of aerosols in the Cheju-Korea Straits and their contribution to the ocean by deposition, aerosol samples were collected on board R/V Eardo from November 1997 to May 1999. The average concentrations of Al, NO3-, non-sea-salt (nss)-SO42-, and NH4+ in aerosols were 2.19, 5.59, 6.16 and 2.08 ㎍ m-3, respectively. The Al concentration in the high yellow dust period was about 100 times higher than that in the non-yellow dust period. The concentration ratio of NO3-/nss-SO42- ranged between 0.47 and 1.5, indicating that the aerosols in the Cheju-Korea Straits are under the effects of NOx and SOx emitted from China, Korea and Japan. The equivalent concentration ratio of [NH4+]/[nss-SO42-+ NO3-] with the average of 0.58±0.29 indicates that nss-SO42- and NO3- are not neutralized by NH4+. A high activity concentration of 210Pb with 1.13-1.23 mBq m-3 was observed during the high yellow dust period, indicating that 210Pb is easily adsorbed in the yellow dust originating from the continent of Asia. The distribution of 7Be and NH4+ concentrations showed a strong negative linear correlation during the low yellow dust period, April 1998. The total mineral dust flux in the Cheju-Korea Straits was estimated to be 1.21×106 tons yr-1, accounting for about 12% of the annual sediment discharge via the Nakdong River. The combined annual deposition of NH4+ and NO3- was 0.103 mole N m-2 yr-1 was estimated to support 4% of the annual primary productivity in the East China Sea.

교량 상판 하부 안전점검 로봇개발 (Development of Robotic Inspection System over Bridge Superstructure)

  • 남순성;장정환;양경택
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.180-185
    • /
    • 2003
  • 도로를 통과하는 차량 통행량의 증가는 장기적으로 교량에 구조적인 손상을 유발시키기 때문에 교량의 유지관리 측면에서 심각한 문제로 대두되고 있으며 준공 단계부터 구조물의 유지관리에 대하여 관심을 기울이지 않으면 공용기간 중 만족할 만한 기능의 유지 및 확보는 불가능하다. 또한, 공황 중에 균열이나 변형 등과 같은 열화손상을 조기에 발견하여 기능상의 장애나 사고를 미연에 방지하기 위해서는 정기적인 점검을 통하여 유지관리를 실시해야 하나 이에 관한 관심도가 상대적으로 낮아 구조물 유지관리에 대한 새로운 인식의 전환과 이와 관련된 기술개발이 절실히 요구되고 있다. 본 연구는 현재 굴절차 또는 점검차에 점검 인력이 직접 탑승하여 실시하는 육안조사를 대체하기 위하여 작은 카메라가 부착된 로봇(Machine Vision System)이 장착된 Linear Motion Control of System을 교량 하부에 설치하고 작업자는 교량 상부에서 외관조사를 수행함으로써 점검자에 따라 주관적으로 점검결과가 도출되는 문제를 근본적으로 해결하고 점검시 안전성을 대폭 개선하며 화상에 검측된 열화 손상 자료를 이미지 프로세싱 기법을 이용하여 객관적이고 정량적인 자료로 저장 및 제공함으로써 교량 유기관리시스템을 위한 데이터베이스를 구축하는데 기여할 수 있는 교량 하부 외관조사 자동화 시스템을 개발하는 데에 그 목적을 두고 있으며 본 시스템을 통하여 교량의 보수 보강 시기를 보다 객관적으로 산정할 수 있어서 현재 매년 기하급수적으로 늘어나는 교량의 보수 보강 비용을 상당히 절감할 수 있을 것으로 기대된다.저장기간을 계산하면, 아세설팜칼륨의 혼용 비율이 높아질수록 저장기간이 길어져서, $50\%$로 혼용하였을 때 가장 긴 저장기간이 산정되어 $20^{\circ}C$에서는 178일, $30^{\circ}C$에서는 88일이 예측되었다. 아스파탐과 아세설팜칼륨의 혼용비율을 5:5, 7:3, 9:1로 달리하여 구연산 완충액 상에 녹인 후, 20, 40, $60^{\circ}C$에서 저장하였다 크기 추정법을 이용하여 단맛을 측정한 결과 20일간의 저장 기간 동안 $20^{\circ}C$$40^{\circ}C$에서는 단맛이 유지되는 것으로 나타났다.산도 $0.4\~0.8\%^{(10)}$에서도 식품 유해가능성을 가진 균이 상당수 검출되므로 원료의 수송, 김치의 제조 및 유통과정에서 병원균에 대한 오염방지에 유의하여야 할 것이다. 확인할 수 있었다. 이상의 결과에 의하면 고농도의 유기물이 함유된 음식물쓰레기는 Hybrid Anaerobic Reactor (HAR)를 이용하여 HRT 30일 정도에서 충분히 직접 혐기성처리가 가능하며, 이때 발생된 $CH_{4}$를 회수하여 이용하면 대체에너지원으로 활용 가치가 높은 것으로 판단된다./207), $99.2\%$(238/240), $98.5\%$(133/135) 및 $100\%$ (313)였다. 각각 두 개의 요골동맥과 우내흉동맥에서 부분협착이나

  • PDF

영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석 (Analysis of the Imaging Dose for IGRT/Gated Treatments)

  • 신정석;한영이;주상규;신은혁;홍채선;안용찬
    • Radiation Oncology Journal
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2009
  • 목적: 영상유도방사선치료(IGRT)와 호흡동조방사선치료(4DRT)의 도입은 치료계획 및 치료부위 확인에서 환자에게 방사선 조사량을 증가시킬 가능성이 있다. 따라서 IGRT/4DRT용 영상장비와 기존 장비에서 영상선량을 측정 및 비교하였다. 대상 및 방법: IGRT 및 4DRT를 위해 새로이 도입된 4DCT (GE, Ultra Light Speed 16)와 모의치료기(Varian Acuity), 그리고 치료기(Varian IX)에 장착된 kVp (OBI)의 영상장비 및 EPID (aSi 1000)를 대상으로, RANDO 팬톰의 표면 선량을 측정하여 기존의 장비들(single slice CT (GE, Light Speed), 모의치료기(Varian, Ximatron), L-gram (Varian 2100C))과 비교하였다. 측정은 열형광선량계를 이용하여 두뇌부, 눈, 갑상선, 흉부, 복부 및 골반부의 표면에서 측정하였다. 결과: 기존 CT와 비교하여 4DCT모드에서는 흉부와 복부에서 10배 이상의 선량증가를 보였다($1.74{\pm}0.34$ vs $23.23{\pm}3.67$ cGy). Acuity에서의 선량은 모든 측정부위에서 Ximatron보다 감소하였다($0.91{\pm}0.89$ vs $6.77{\pm}3.56$ cGy). EPID는 기존 L-gram 선량의 약 50% ($1.83{\pm}0.36$ vs $3.80{\pm}1.67$ cGy)였다. OBI의 투시영상선량은 $0.97{\pm}0.34$ cGy며, CBCT 선량은 $2.3{\pm}0.67$ cGy였다. 결론: 4DCT가 선량증가의 가장 큰 원인이며, OBI와 CBCT에 의한 선량은 적으나 매번 치료에 적용 시 총 선량 증가에 대한 고려가 필요하다.

지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가 (Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation)

  • 윤명오;고재선;박형주;박성은
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.23-33
    • /
    • 2001
  • 지하공동구는 최근 통신의 발달로 인해 국가 중추기능으로서의 주요 역할을 하는 시설로, 사고시 신속한 대처가 힘들고 케이블 연소시 발생하는 유독가스에 의한 검은 연기로 공동구 내에 진입하여 소화화기가 힘들다. 따라서, 화재발생시 막대한 재산피해 및 통신의 두절 등 국가의 중추신경이 마비됨은 물론 시민 불편사항을 초래시켰다. 본 논문은 지금까지 발생되어온 공동구 화제를 바탕으로 실제 공동구 모형을 제작하여 화재를 재현함으로서, 과학적으로 화재의 성상을 분석하고 지하공동구 내에 소방설비를 갖춘 후에 일정온도에서 각각의 소방설비들이 제대로 작동하는지를 검증하는데 그 목적이 있다. 화재실험은 지하 공동구 내에 정온식 감지선형 감지기, 방화문, 연결살수설비 및 환기설비를 설치하고 송.배전케이블은 일정구간 내화도료로 도장하며 난방관은 내화피복된 상태에서 실험하였다. 그 결과 최고 온도가 $932^{\circ}c$로 측정되었고 일정온도에서 정온식 감지선형 감지기가 작동하여 화재위치를 정확히 수신반에 나타내었다. 그리고 송.배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복된 난방관은 약 30분 정도의 내화 성능이 있는 것으로 나타났다. 컴퓨터 화재 시뮬레이션은 실제 화재 시험시의 화재하중을 입력하여 실시한 결과 최고 온도가 $943^{\circ}c$로 실제 화재시의 최고 온도인 $932^{\circ}c$와 거의 일치하였다. 따라서 공동구 화재하중만으로 화재 시뮬레이션을 실시하여 화재의 성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻는 열방출량, 연기층의 높이, 산소, 일산화탄소, 이산화탄소의 농도 등의 결과 값들을 실제 화재 실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 0.05ppb보다 높은 수준으로 예측되어 유럽의 허용기준치를 초과하는 것으로 나타났다.확보를 위한 위생관리 업무 향상을 위해서는 본 연구에서 가장 취약한 부분으로 드러난 시설 및 기기들을 우선 보완해야 할 것으로 사료된다.ons. Specific growth rate of dechlorinators showed little difference between the slurry and the low-moisture sediments; however, growth yield was high in the sediments of reduced moisture content. The reduction of sediment moisture decreased the dechlorination rate and extent of PCBs but did not inhibit the growth of PCB dechlorinators.1.4mg, 여학생이 159.3mg이었다. 이상의 결과로 보아 에너지, 단백질, 칼슘, 비타민 A 등 대부분의 영양소 섭취량이 권장량에 미치지 못하여 성장기에 있는 아동들의 영양소 섭취 상태에 문제가 있음을 시사해 주었다. 5. 조사 대상자의 식습관과 영양소 섭취량의 상관관관계는 식사 시간의 규칙성은 단백질, 식이성 섬유소, 비타민 A 및 티아민섭취량과 양의 상관을 나트륨섭취량과는 음의 상관관계가 있었다. 음식의 간(염도)은 인과 콜레스테롤 섭취와 음의 상관관계를 나타냈다. 들깨가루나 들기름 사용 여부는 열량, 탄수화물 및 인의 섭취량과 음의 상관을, 지방, 철분, 리보플라빈 및 나이아신섭취량과는 양의 상관관계를 나타냈었다. 결식여부는 지방, 철분 및 나이아신섭취량과는 양의 상관관계를, 열량, 탄수화물, 인 나트륨, 및 콜레스테롤섭취량과는 음의 상관을 보였다. 외식이

  • PDF

Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석 (Analysis of Respiratory Motional Effect on the Cone-beam CT Image)

  • 송주영;나병식;정웅기;안성자;남택근;윤미선
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.81-86
    • /
    • 2007
  • 영상유도 방사선치료의 대표적 방법의 하나로 선형가속기에 부착된 on-board imager (OBI) 영상장치를 사용하여 획득한 cone-beam CT (CBCT) 영상이 정밀 방사선치료 시 환자 정렬 오류를 보정하는데 활용되고 있다. 본 연구에서는 CBCT 영상 획득 시 환자 호흡에 의한 영상 품질과 정보의 변화를 분석하고자 호흡 움직임을 모사할 수 있는 팬텀과 CBCT 영상획득용 팬텀을 제작하고, 여러 움직임 조건에서 획득한 CBCT 영상들과 정지상태에서 얻은 CBCT 영상과의 비교, 분석을 수행하였다. 분석대상 움직임 조건을 구성하는 요소로서 움직임 주기는 5가지(2초, 3초, 4초, 5초, 6초)를 선정하였고, 움직임 변위 크기는 4가지(0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm)를 선정하여 총 20가지의 움직임 조건에서 CBCT 영상을 획득하였다. CBCT 영상의 CT값의 상대적 크기로 비교한 영상 화소 값 강도의 평균 변화는 정지 상태의 영상과 비교하여 변위가 0.7 cm의 경우 71.07%, 1.6 cm의 경우 48.88%, 2.4 cm의 경우 30.60%, 3.1 cm의 경우 17.38% 값을 보였고, 팬텀 움직임 방향의 영상 길이는 정지상태에서 2.1 cm, 움직임 변위가 0.7 cm의 경우 2.66 cm, 1.6 cm의 경우 3.06 cm, 2.4 cm의 경우 3.62 cm, 3.1 cm의 경우 4.04 cm 값을 보여 움직임 변위 크기가 클수록 영상 품질 저하와 형태적 정보의 왜곡정도도 증가하였다. 움직임 주기에 의한 영상품질의 변화는 움직임 변위 크기가 작은 경우를 제외하고는 특별한 영향이 없었다. 본 연구를 통해 환자 호흡에 의한 움직임 변위가 큰 부위의 CBCT 영상을 획득할 때, 영상 품질과 정보에 변화가 발생할 수 있어 이 점을 고려하여 임상에 사용해야 하며, 궁극적으로 호흡 신호와 연동된 CBCT 영상이 필요함을 확인할 수 있었다.로버 + 혼파초지에 비하여 낮은 결과를 보였다(p<0.05). 2년 평균 CPDM 수량은 레드 클로버 + 혼파초지가 2,832kg으로 관행 혼파초지(2,372kg)나 잔디형 초종 + 혼파초지(2,266kg)에 비하여 높은 결과를 나타내었다(p<0.05). 2년 평균 DDM 수량은 레드 클로버 + 혼파초지가 8,881kg으로 관행 혼파초지(8,255kg)나 잔디형 초종 + 혼파초지(7,314kg)에 비하여 높은 결과를 얻었다(p<0.05). 2005년 5회 예취시의 식생비율은 관행 혼파초지는 orchardgrass는 45%, tall fescue 22%, Kentucky bluegrass 5% 및 white clover 24%이었으며, 레드 클로버 + 혼파초지는 orchardgrass 40%, tall fescue 22%, Kentucky bluegrass 4% 및 red clover 31%이었고, 잔디형 초종 + 혼파 초지는 orchardgrass 37%, 잔디형 초종 37%(tall fescue 23%, Kentucky bluegrass 6%, perennial ryegrass 8%) 및 white clover 23%를 유지하였다. 이상의 결과를 종합할 때, 초종과 파종비율에 따른 혼파초지의 건물수량과 사료가치의 차이를 확인할 수 있었으며, 레드 클로버 + 혼파 초지가 건물수량과 사료가치를 높이는데 효과적이었다.\ell}$ 이었으며 , yeast extract 첨가(添加)하여 배양시(培養時)는 yeast extract 농도(濃度)가 증가(增加)함에 따라 단백질(蛋白質) 함량(含量)도 증가(增加)하였다. 7. CHS-13 균주(菌株)의 RNA 함량(含量)은 $4.92{\times}10^{-2 }\;mg/m{\ell}$이었으며 yeast extract 농도(濃度)가 증가(增加)함에 따라 증가(增加)하다가 농도(濃度) 0.2%에서 최대함량(最大含量)을 나타내고

  • PDF

직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구 (In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma)

  • 이황규;지금난;홍수진;고재향
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.133-143
    • /
    • 2013
  • 목적 : 직결장암 조직의 자기공명영상과 고주파 초음파검사를 시행한 후 종양의 탐지와 침윤 깊이에 대해 각각의 영상 소견과 병리 소견을 비교하여 진단적 정확도를 두 영상 기기 간 비교하고, 자기공명영상의 경우 종양의 침윤 깊이를 주변 정상 조직과 가장 명확히 보여주는 펄스 연쇄 (pulse sequence)에 대해 알아보았다. 대상 및 방법 : 직결장암으로 절제술을 시행한 45명의 환자에서 얻은 45예의 제거된 종양 조직을 수조에 넣고 생리 식염수에 담가서 고주파수 (5-17 MHz)의 선형 탐촉자를 이용하여 초음파영상을 얻었으며 8-channel 두경부 코일에 넣어 자기공명영상을 얻었다. 이 연구에 대하여 기관감사위원회의 공지에 입각한 동의는 면제되었다. 자기공명영상은 정- 및 탈위상 경사에코 T1 강조영상, 급속스핀에코 T2 강조영상 및 이의 지방억제 영상, fast imaging employing steady-state acquisition (FIESTA)와 이의 지방억제영상, 확산강조영상 등 일곱 가지 펄스 연쇄를 시행하였다. 각 조직의 자기공명영상과 초음파영상 소견을 각각 독립적으로 종양의 탐지와 침윤 깊이에 대하여 두 명의 영상의학과 의사가 합의 하에 평가하였고 각각의 영상 소견을 병리 조직 소견과 비교하여 두 영상 기기 간 진단적 정확도를 비교하였다. 자기공명영상의 일곱 가지 펄스 연쇄 중에 종양의 침윤 깊이를 주변 정상 조직과 구분하여 명확히 보여주는 펄스 연쇄에 대해 알아보았다. 결과 : 직결장암 조직의 종양 탐지와 침윤 깊이를 평가하는데 있어 자기공명영상과 초음파의 진단적 정확도는 각각 91.1%와 86.7%로 높게 나타났다. 조기 직결장암의 경우 초음파 검사의 정확도는 87.5%, 자기공명영상 검사의 정확도는 75.0%로 나왔다. 두 영상 기기 간에 통계적으로 유의한 차이는 없었다 (p > 0.05). MR의 펄스 연쇄 중에 종양의 침윤 깊이를 주변 정상 조직과 구분하여 명확하게 보여주는 영상은 직결장암 및 조기 직결장암 모두 급속 스핀에코 T2 강조영상이었다. 결론 : 자기공명영상과 초음파 검사는 직결장암 조직의 종양 탐지와 침윤 깊이를 평가하는데 높은 진단적 정확도를 가지고 있으며, 자기공명영상의 급속스핀에코 T2 강조영상이 직결장암 조직의 종양 침윤 깊이를 평가하는데 가장 우수하였다.

세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가 (Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy)

  • 도경민;정덕양;김영범
    • 대한방사선치료학회지
    • /
    • 제21권2호
    • /
    • pp.83-88
    • /
    • 2009
  • 목 적: 온 보드영상(OBI)장치를 이용한 콘빔CT는 환자 치료 중 실시간으로 전산화모의치료 영상과 비교하여 환자의 자세 및 표적용적의 움직임과 셋업오차를 확인 할 수 있다. IMRT 시 콘빔CT를 이용해 환자의 자세 및 표적용적의 변화와 움직임을 확인하여 치료계획과의 오차정도를 산출하고, Automatic Match System을 이용하여 위치 보정을 한 후 전자포털영상 장치를 통하여 위치보정의 정확성을 검증하고, IMRT에서 콘빔CT의 유용성과 Automatic Match System의 정확성에 대하여 알아보고 자 한다. 대상 및 방법: 본원에서 치료받은 IMRT 환자 중 두 경부 치료환자 3명, 골반부 치료환자 1명을 대상으로 치료 자세의 변동과 그에 따른 조사용적의 위치변동을 알아보기 위해 선형가속기에 장착된 온 보드 영상 장치를 이용해 콘빔 CT를 촬영하였다. IMRT 전 매 치료 시 마다 콘빔CT를 촬영하여 전산화단층모의치료 영상과 비교하여 좌표별로 치료계획과의 오차값을 확인하고 3D/3D Match의 Automatic Match System을 통하여 치료계획과 일치하도록 이동 보정한 후 전자포털영상 장치를 이용하여 검증, 평가하였다. 결 과: 치료 전 콘빔 CT와 전산화단층모의치료 영상 비교 시 두 경부에서 좌표별 평균오차는 Vertical 0.99 mm, Longitudinal 1.14 mm, Lateral 0.84 mm, Rotation $0.49^o$이고, 골반부의 평균오차는 Vertical 2.78 mm, Longitudinal 2.04 mm, Lateral 4.91 mm, Rotation $1.07^o$로 부위별로 다소 근소한 차이를 보였다. 보정 후 검증에서는 전자포털영상 장치에 의한 영상과 DRR 영상 비교 결과 0.5 mm 이내의 오차로 정확한 보정이 이루어졌음을 알 수 있었다. 결 론: 치료 전 콘빔CT 영상은 환자의 셋업오차와 장기 및 표적의 위치변화를 2차원적 영상의 비교와 달리 하나의 체적으로 재구성된 3차원적 영상으로 비교함으로써 보다 정확하게 위치변화와 표적용적의 변동 등을 측정, 보정하여 정확한 치료를 할 수 있으며, 그 오차 값을 산출하여 비교할 수 있다. 이상의 연구로 보아 콘빔CT는 치료계획과 일치하는 정확한 치료전달과 반복적인 치료재현성에 유용하였으며, 만족스러운 결과를 얻을 수 있었다. 콘빔CT에 의해 향상된 정확도는 복잡한 모양의 표적용적과 급격한 선량분포의 변화가 나타나는 IMRT에서 더욱 필요하며 각 치료 부위별, 치료 목적별로 Match focus에 대한 기준을 연구해야 될 것으로 사료된다.

  • PDF

동해 극전선역의 영양염류 순환 과정 III. 1995년 10월 동해 중부 및 북부 해역의 수괴와 영양염의 분포 (Regeneration Processes of Nutrients in the Polar Front Area of the East Sea III. Distribution Patterns of Water Masses and Nutrients in the Middle-Northern last Sea of Korea in October, 1995)

  • 조현진;문창호;양한섭;강원배;이광우
    • 한국수산과학회지
    • /
    • 제30권3호
    • /
    • pp.393-407
    • /
    • 1997
  • 1995년 10월 탐양호를 이용하여 동해 중부 및 북부해역의 28개 정점에서 CTD 관측과 동시에 영양염의 분포 특성을 최대 500m 깊이까지 조사하였다. 수온${\cdot}$염분 및 용존산소로서 조사해역의 수괴는 동해표층저염수 (Low Saline Surface Water, LSSW), 대마난류표층수 (Tsushima Surface Water, TSW), 대마난류중층수 (Tsushima Middle Water, TMW), 북한한류수(North Korean Cold Water, NKCW) 및 동해고유수 (East Sea Proper Water, ESPW) 등의 5개 주수괴와 각 수괴들의 혼합수로 이루어졌다. 특히 조사해역의 남쪽 지점의 수심 $0\~30m$에서 출현한 동해표층저염수는 이 곳에 특별한 달수 공급원이 없는 것으로 보아 중국의 양자강 유출수가 유입된 것으로 판단된다. 산소 최대층은 조사해역 북쪽에서는 표층 근처에 나타나고 남쪽으로 갈수록 그 수심이 깊어졌으며 대마난류중층수의 특징인 용존산소 최소층은 남쪽 해역에서만 출현하였다. 영양염은 표층에서 낮고 수온약층에서 증가하여 동해고유수에서 최대이었다. 동해고유수에서 규산염과 인산염의 비 (Si/P ratio)가 13.63으로 이제까지 동해에서 보고된 수치에 비하여 매우 낮았는데 괴는 P가 수심에 따라 계속 증가하는 양상이었기 때문이다. 질산염과 인산염의 비 (N/P ratio)는 약 6.92로 대마난류표층수를 제외하고 질산염이 식물플랑크톤 성장의 제한 요소로 작용하고 있었다. N과 P는 양의 직선관계를 보였으나 Si와 P의 관계는 지수적 증가를 보여 규산염의 재생산 속도가 느림을 보여주고 있다.

  • PDF

ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링 (Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System)

  • 한희조;김학진;정대현;조우재;조영열;이공인
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.141-152
    • /
    • 2020
  • 본 연구는 양액 내 존재하는 다량 영양소의 농도를 실시간으로 측정하기 위해 이온 선택 전극 (ISE) 으로 구성된 임베디드 시스템의 개발을 보여준다. NO3, K 및 Ca 이온을 감지하기위한 PVC ISE, H2PO4를 감지하기위한 코발트 전극, 기준 전극, 샘플 용액이 담기는 챔버, 펌프 및 밸브를 사용하여 측정하는 시스템으로 구성된다. 양액 샘플양 조절과 데이터 수집을 위해서 데이터 Due 보드가 사용되었고, 각각의 샘플 측정 전에, 측정 중 발생하는 드리프트를 최소화시키기 위해 2 점 정규화 방법을 사용하였다. PVC 멤브레인을 기반으로 한 NO3 및 K 전극의 농도 예측 성능은 표준 분석기의 결과와 근접한 일치 (R2 = 0.99) 나타내며 만족스러운 결과를 나타냈다. 하지만, Ca II 이온 투과체 제조된 Ca 전극은 고농도 양액 농도에서 Ca 농도를 55 %로 낮게 측정하였다. 코발트 전극 기반 인산 측정은 반복측정 중에 발생한 코발트 전극의 불안정한 신호로 인해 표준 방법과 비교하여 45 ~ 155 mg / L의 인산 농도 범위에서 24.7 ± 9.26 %의 비교적 높은 오차를 나타냈다. 수경 P 감지의 예측 능력을 향상시키기 위해 코발트 전극의 신호 컨디셔닝에 대한 추가 연구가 필요함으로 판단된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF