• Title/Summary/Keyword: linear scanning method

Search Result 135, Processing Time 0.049 seconds

Skew Detection for Thai Printed Document Images

  • Premchaiswad, Wichian;Duangphasuk, Surakarn
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.326-328
    • /
    • 2000
  • The paper proposes the scheme of skew detection for Thai printed document images by using linear regression algorithm. It intends to use with the Thai character recognition systems to reduce the skew detection time. This scheme begins by finding the center of gravity of a document image. This point is used as the starting point for gathering data in the scheme. The data is obtained by scanning incrementally one pixel in vertically with the width of 20-pixels. After the scanning process, if data Is different from it's neighbor more than ${\pm}$ 15 pixels, it will be considered as noise or data in other lines and will be deleted. The last step is the operation by using linear regression algorithm on these selected data and the skew angle will be obtained. The proposed method has been tested with 45 document images with different fonts, sizes and skew angles. The experiment results show that the proposed method can detect the skew angle with the error of less then one degree. The average processing time is about 19 times faster than that of the Hough Transform method.

  • PDF

Development of On-machine Flatness Measurement Method (평면도 기상 측정 방법 개발)

  • 장문주;홍성욱
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • This paper presents an on-machine measurement method of flatness error fur surface machining processes. There are two kinds of on-machine measurement methods available to measure flatness errors in workpieces: i.e., surface scanning method and sensor scanning method. However, motion errors are often engaged in both methods. This paper proposes an idea to realize a measurement system of flatness errors and its rigorous application for estimation of motion errors of the positioning system. The measurement system is made by modifying the straightness measurement system, which consists of a laser, a CCD camera and processing system, a sensor head, and some optical units. The sensor head is composed of a retroreflector, a ball and ball socket, a linear motion guide unit and adjustable arms. The experimental .results show that the proposed method is useful to identify flatness errors of machined workpieces as well as motion errors of positioning systems.

Design and Control of Ultra-precision Dual Stage with Air bearings and Voice coil motor for nm scanning system (나노 정밀도 스캐닝 용 공기베어링과 보이스 코일 모터의 초정밀 이중 스테이지 설계 및 제어)

  • Kim K.H.;Choi Y.M.;Kim J.J.;Lee M.G.;Lee S.W.;Gweon D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1883-1886
    • /
    • 2005
  • In this paper, a decoupled dual servo (DDS) stage for ultra-precision scanning system with large working range is introduced. In general, dual servo systems consist of a fine stage for short range and a coarse stage for long range. The proposed DDS also consists of a $XY\theta$ fine stage for handling and carrying workpieces and one axis coarse stage. Its coarse stage consists of air bearing guide system and a coreless linear motor with force ripple. The fine has four voice coil motors(VCM) as its actuator. According to a VCM's nature, there are no mechanical connections between coils and magnetic circuits. Moreover, VCM doesn't have force ripples due to imperfections of commutation components of linear motor systems - currents and flux densities. However, due to the VCM's mechanical constraints the working range of the fine is about $25mm^2$. To break that hurdle, the coarse stage with linear motors is used to move the fine about 500mm. Because of the above reasons, the proposed DDS can achieve higher precision scanning than other stages with only one servo. With MATLAB's Sequential Quadratic Programming (SQP), the VCMs are optimally designed for the highest force under conditions and constraints such as thermal dissipations due to its coil, its size, and so on. And for their movements without any frictions, guide systems of the DDS are composed of air bearings. To get precisely their positions, a linear scale with 5nm resolution are used for the coarse stage's motion and three plane mirror laser interferometers with 5nm for the fine's $XY\theta$ motions. With them, on scanning the two stages have same trajectories. The control algorithm is named Parallel method. The embodied ultra-precision scanning system has sub 100nm following error and in-positioning stability.

  • PDF

Kinetic Measurements on Elastomer by Differential Scanning Calorimetry (Differential Scanning Calorimetry에 의(依)한 탄성체(彈性體)의 속도론적(速度論的) 연구(硏究))

  • Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.22 no.4
    • /
    • pp.333-339
    • /
    • 1987
  • A modern kinetic evaluation method for nonisothermal reactions measured with Differential Scanning Calorimetry(DSC) is presented. It is based on multiple linear regression analysis using a number of curve points in a selectable range of conversion. The obtained kinetic data are the basis to compute a reaction process under any condition e.g. isothermal or adiabatic. The DSC measurements was performed on a Mettler TA3000 SYSTEM with the built in evaluation software. Mainly the following reactions are discussed: vulcanization of natural rubber compounds containing vulcanizing accelerators. The purpose of this work is to analyse the vulcanization kinetics of typical NR vulcanization systems using DSC. These systems were chosen because they are typically reactive elastomer and are commercially important.

  • PDF

Implementation of Optimal User Interface based on the Voice Output Embedded System for People with Profound Communication Disorder (중증언어장애자를 위한 음성 출력 임베디드 시스템을 기반으로 한 최적의 사용자 인터페이스 구현)

  • Yoo, Byung-Hyuk;Lee, Sang-Hun;Seo, Hee-Don
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.885-886
    • /
    • 2006
  • The purpose of this study is to develop the optimal system(AAC device), which helps a person with a profound communication disorder to communicate with other people. Therefore, this system includes the user interface enhancement that is the user adaptation mode algorithm. The symbol is made with a text and an icon which is converted into Korean. The message contiol operates scanning and adjusts rate control of row-column scanning and linear scanning. This embedded system includes voice input/output and voice recording as well suggested method that could apply optimal device access algorithm from clinical environment. Therefore, we are experting that even the current system itself will be able to improve the life quality of people who need to communicate with the help of devices.

  • PDF

Correction of Photometric Distortion of a Micro Camera-Projector System for Structured Light 3D Scanning

  • Park, Go-Gwang;Park, Soon-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • This paper addresses photometric distortion problems of a compact 3D scanning sensor which is composed of a micro-size and inexpensive camera-projector system. Recently, many micro-size cameras and projectors are available. However, erroneous 3D scanning results may arise due to the poor and nonlinear photometric properties of the sensors. This paper solves two inherent photometric distortions of the sensors. First, the response functions of both the camera and projector are derived from the least squares solutions of passive and active calibration, respectively. Second, vignetting correction of the vision camera is done by using a conventional method, however the projector vignetting is corrected by using the planar homography between the image planes of the projector and camera, respectively. Experimental results show that the proposed technique enhances the linear properties of the phase patterns that are generated by the sensor.

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

Determination of the Virtual Focus Position for Electron Beam with Air Scanning (전자선에서 Virtual Source Distance의 위치 결정)

  • Kwon Kyung Tea;Youn Wha Ryong;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.89-93
    • /
    • 1994
  • Authors have measured virtual source distance of electron beam from CL/1800 medical linear accelerator, with newly designed method. Beam scanning was performed with the direction of beam axis in the air. Compared results between this study and well established in phantom measurement shows good agreement with in experimental error. And we have found that build-up cap plays very important role in air measurement because of charge build up. The method of in-air measurement of virtual source distance is very easy to set-up and generate accurate results.

  • PDF

A Study on the Microdetermination of Nicotine in Contaminated Beverage by Thin-Layer Chromatography (커피음료중(飮料中)에 위화(僞和)된 Nicotine의 미량분석(微量分析)에 관(關)한 연구(硏究))

  • Lee, Duk-Heng;Lee, Yong-Joo
    • Korean Journal of Pharmacognosy
    • /
    • v.10 no.1
    • /
    • pp.23-25
    • /
    • 1979
  • A trace amount of nicotine, main constituent in tobacco, contaminated in coffee, was identified by the T.L.C method. The Eastman chromagram plate was used and determined with the linear scanning by transmission method. It was possible to identify nicotine in coffee beverage regardless of types of tobacco. Ten micrograms of nicotine could be determined in a cup of coffee (75ml), which was acidified with hydrochloric acid.

  • PDF

The Basic Study on Design of Linear Pulse Motor for Embroidery Machine Characteristics (자수기 특성을 고려한 LPM의 설계에 관한 기초연구)

  • Park, Chang-Soon;Kwon, Tae-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.765-767
    • /
    • 2001
  • Linear pulse Motors(LPM) are widely used in fields where smooth linear motion is required, and their position accuracy is higher than other motors. Hybrid linear pulse motors(HLPM) are regarded as an excellent solution to positioning problems that require high accuracy, rapid acceleration and high-speed. The LPM has low mechanical complexity, high reliability, precise open-loop operation and low inertia etc. in many application areas such as factory automation speed positioning, computer peripherals and numerically controlled machine tools. This motor drive system is especially suitable for machine tools the high position accuracy and repeatability. This paper describes about that need of the embroider machine, we want to design position-scanning device for the embroidery machine. At first, to be analysed characteristics of the machine and next designed the LPM. we used the field analysis program, The finite element method(FEM) program tool is employed for calculation the force. The reluctance models will be used the magnetic permeance of air gap by static- conditions. The forces between forcer and platen have been calculated using the virtual work method.

  • PDF