• Title/Summary/Keyword: linear polarization test

Search Result 43, Processing Time 0.034 seconds

Corrosion Evaluation of Epoxy-Coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests

  • Choi, Oan-Chul;Jung, Si-Young;Park, Young-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.3-9
    • /
    • 2006
  • Five slab specimens with predefined cracks are examined to evaluate the corrosion behavior of epoxy-coated bars in chloride contaminated concrete, using linear polarization method. The test specimens were subjected to alternating weekly cycles of ponding in a salt solution and drying for 48 weeks. Test results show that the current density of the specimen of normal steel bars becomes 0.715 ${\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy-coated bars are significantly below 0.1 ${\mu}A/cm^2$ and the bars appears to be in passive condition. The damaged epoxy-coated bars with a corrosion inhibitor of calcium nitrite showed a corrosion rate of 0.110 ${\mu}m/year$ or 56 percents of the corrosion rate of damaged epoxy-coated specimen without such an inhibitor, 0.195 ${\mu}m/year$. However, the corrosion rates of specimens containing the other two corrosion inhibitors, a combination of amines and esters or mixtures of organic alkenyl dicarboxyl acid salts are quite equivalent to the control specimen. The research technique of linear polarization resistance method has proven itself to be useful in measuring corrosion rates of reinforcement in concrete.

Study on the Cavitation Damage of Cupronickel(70/30) Tube for Gas Absorption Refrigeration Machine

  • Lim, Uh-Joh;Jeong, Ki-Cheol;Yun, Byoung-Du
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.332-337
    • /
    • 2004
  • The use of gas absorption refrigeration machine has considerably increased because of the shortage of the electric power in the summer and the regulation of freon refrigerant. Gas absorption refrigeration machine consists of a condenser, a heat exchanger. supplying pipes, a radiator etc, This system is likely to be corroded by acid. dissolved oxygen and gases, Cavitation erosion-corrosion by flow velocity of cooling water may happen in absorption refrigeration machine. In these cases. erosion and corrosion occur simultaneously. Then, it makes a serious damage with synergy effect. Therefore, this paper was studied on the cavitation damage of cupronickel(70/30) tube for gas absorption refrigeration machine, In the $30^{\circ}C$ tap water, linear polarization test and anodic polarization test were carried out for copper(C1220T-OL) and cupronickel(70/30) tube. Also, cavitation erosion-corrosion behavior of cupronickel (70/30) tube was considered, The main results are as following: (1) In the linear test, the corrosion current density of cupronickel(70/30) is higher than that of copper. (2) The erosion-corrosion rate of cupronickel(70/30) displayed later tendency than that of copper by vibratory cavitation in cooling water. (3) In cooling water, the progress mechanism of erosion-corrosion rate of copper and cupronickel(70/30) follows a pattern of incubation, acceleration, attenuation and a steady state period.

Corrosion Evaluation of Epoxy-coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests (염화물 환경에 있는 에폭시도막철근의 부식 평가 연구)

  • Park, Young-Su;Choi, Kyong-Min;Jung, Si-Young;Kim, Byoung-Kook;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.254-257
    • /
    • 2006
  • Five bench scale specimens were used to evaluate corrosion performance of damaged epoxy-coated bars in chloride contaminated concrete. The test specimens were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. Test results using linear polarization technique show that the current density of specimen with conventional steel becomes $0.715\;{\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy coated bars are much below $0.1\;{\mu}A/cm^2$ and the bars appears to be in passive condition. The corrosion protection performance provided by calcium nitrite is better than that of specimens with the other two inhibitors.

  • PDF

DIVERSITY DESIGN FOR SENSOR DATA ACQUISITION AT COMS SOC

  • Park, Durk-Jong;Koo, In-Hoi;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.479-481
    • /
    • 2007
  • COMS will transmit its observed data, Sensor Data, through L-Band with linear polarization. To avoid link loss caused by polarization discrepancy between satellite and SOC DATS, the L-Band antenna at SOC DATS should be linearly polarized. However, SOC DATS is supposed to share single antenna with SOC TTC, so the antenna should be circularly polarized. To cope with about 3dB loss, SOC DATS is designed to receive Sensor Data through two orthogonal circular polarizations, RHCP (Right-Hand Circular Polarization) and LHCP (Left-Hand Circular Polarization). Eventually, SOC DATS can obtain 2.6dB of combining gain through diversity combiner in MODEM/BB. This paper presents the verification on the diversity combining of SOC DATS with test configuration and results in depth.

  • PDF

An Investigation on Application of Experimental Design and Linear Regression Technique to Predict Pitting Potential of Stainless Steel

  • Jung, Kwang-Hu;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.52-61
    • /
    • 2021
  • This study using experimental design and linear regression technique was implemented in order to predict the pitting potential of stainless steel in marine environments, with the target materials being AL-6XN and STS 316L. The various variables (inputs) which affect stainless steel's pitting potential included the pitting resistance equivalent number (PRNE), temperature, pH, Cl- concentration, sulfate levels, and nitrate levels. Among them, significant factors affecting pitting potential were chosen through an experimental design method (screening design, full factor design, analysis of variance). The potentiodynamic polarization test was performed based on the experimental design, including significant factor levels. From these testing methods, a total 32 polarization curves were obtained, which were used as training data for the linear regression model. As a result of the model's validation, it showed an acceptable prediction performance, which was statistically significant within the 95% confidence level. The linear regression model based on the full factorial design and ANOVA also showed a high confidence level in the prediction of pitting potential. This study confirmed the possibility to predict the pitting potential of stainless steel according to various variables used with experimental linear regression design.

Design of Current Probe Using Faraday Effect of Optical Fiber (광 파이버의 패러데이 효과를 이용한 전류측정용 프로브 설계)

  • Kang, Hang-Sik;Kim, Chul-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1278-1280
    • /
    • 1995
  • A probe type fiber-optic sensing techique for electric current measurement is applied in this paper. The technique is based on the Faraday effect which meaning is that polarization state of light is rotated by magnetic field. In experiment, test wire is located at inside and outside of the probe to be measured. The experimental results prove not only linear property, but also polarization rotation property according to the distance from outside of probe.

  • PDF

Separation of Seismic Signals using a Polarization Filter based on the Complex Trace Analysis Method (복소트레이스 분극필터를 이용한 다성분 탄성파자료 신호분리)

  • Kim, Ki-Young;Lee, So-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.233-236
    • /
    • 2005
  • Polarization filtering based on the multicomponent complex trace analysis method is performed to reject Rayleigh waves and to enhance S waves. To test the polarization filter, synthetic seismic data were constructed for a simple two-layer model based on the finite difference method. Rayleigh waves with elliptic motion are eliminated effectively and P and S waves with linear motions are well separated each other.

  • PDF

Separation of Seismic Signals using a Polarization Filter based on the Complex Trace Analysis Method (복소트레이스 분극필터를 이용한 다성분 탄성파자료 신호분리)

  • Kim, Ki-Young;Lee, So-Young
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.1
    • /
    • pp.35-38
    • /
    • 2005
  • Polarization filtering based on the multicomponent complex trace analysis method is performed to reject Rayleigh waves and to enhance S waves. To test the polarization filter, synthetic seismic data were constructed for a simple two-layer model based on the finite difference method. Rayleigh waves with elliptic motion are eliminated effectively and P and S waves with linear motions are well separated each other.

  • PDF

Evaluation on Resistance to Pitting Corrosion of Fe-Cr Alloys via Measurement of the Critical Pitting Temperature (CPT) and Potentiodynamic Polarization According to KS D 0238 (wet, dry), ASTM G 61 and ISO 17475 Standards (Fe-Cr합금의 공식저항성 평가를 위하여 다양한 규격(KS D 0238, ASTM G 61, ISO 17475)에 따라 실시한 동전위 분극 시험과 임계공식온도 측정시험)

  • Kang, Su-Yeon;Lee, Jae-Bong;Kim, Yeong-Ho
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.10
    • /
    • pp.635-643
    • /
    • 2009
  • The resistance to pitting corrosion of Fe-Cr alloys was evaluated by performing potentiodynamic polarization and critical pitting temperature (CPT) tests. For the potentiodynamic polarization tests, various standards were applied, i.e., KS D 0238 (wet, dry), ASTM G 61, and ISO 17475, showing different potentiodynamic polarization results including pitting potentials. ASTM G 61 and ISO 17475 standards presented relatively higher pitting potential while KS D 0238 (dry) indicated lower values than the others. Effects of surface roughness, scan rates, and exposure time to air before tests were also investigated. CPT tests were performed under two different applied potentials, 300 m$V_{SCE}$ and 200 m$V_{SCE}$ in deaerated 1 M NaCl aqueous solution. CPT values and the polarization test results showed a linear relationship.

Corrosion Evaluation of Epoxy-Coated Bars by Electrochemical Impedance Spectroscopy

  • Choi, Oan-Chul;Park, Young-Su;Ryu, Hyung-Yun
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.99-105
    • /
    • 2008
  • Southern exposure test specimens were used to evaluate corrosion performance of epoxy-coated reinforcing bars in chloride contaminated concrete by electrochemical impedance spectroscopy method. The test specimens with conventional bars, epoxy-coated bars and corrosion inhibitors were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. The polarization resistance obtained from the Nyquist plot was the key parameter to characterize the degree of reinforcement corrosion. The impedance spectra of specimens with epoxy-coated bars are mainly governed by the arc of the interfacial film and the resistance against the charge transfer through the coating is an order of magnitude higher than that of the reference steel bars. Test results show good performance of epoxy-coated bars, although the coatings had holes simulating partial damage, and the effectiveness of corrosion-inhibiting additives. The corrosion rate obtained from the impedance spectroscopy method is equivalent to those determined by the linear polarization method for estimating the rate of corrosion of reinforcing steel in concrete structures.