• 제목/요약/키워드: linear polarization

검색결과 318건 처리시간 0.026초

Study of The Anisotropy of Electron Energy Distribution of Optical-Field Ionized Oxygen Plasma by Using Polarization Spectroscopy

  • Kim, Dong-Eon;Kim, Jae-Hoon;Kawachi, Tetsuya;Hasegawa, Noboru;Sukegawa, Kouta;Iwamae, Atsushi;Fujimoto, Takashi
    • Journal of the Optical Society of Korea
    • /
    • 제7권3호
    • /
    • pp.145-149
    • /
    • 2003
  • The anisotropy of electron energy distribution in oxygen plasmas produced by a high intensity laser was investigated by using polarization spectroscopy. An ultra-short pulsed laser with a pulse duration of 66.5 fs and a power density of $1 {\times} 10^17/ W/$\textrm{cm}^2$$ was used. At this power density and pulse duration, the plasma was generated predominantly by optical field ionization. The degree of polarization of OVI 1s$^2$2p$^2$p2- 1s$^2$4d$^2$D$^{0}$ (J = 1/2-3/2 and 3/2-5/2) transition line at 129.92 $\AA$ was measured. O VI 1s$^2$2p$^2$P$^2$ -1s$^2$4s$^2$S$^2$ (J = 1/2-1/2 and 3/2-1/2) transition line at 132.26 $\AA$ was used to calibrate the sensitivity of the optical system. The dependencies of the degree of polarization on the initial gas density and on the laser polarization were investigated. When the laser polarization was changed from a linear to a circular polarization, the degree of polarization was decreased. When the initial gas density was increased, the degree of polarization was decreased.

광 파이버의 패러데이 효과를 이용한 전류측정용 프로브 설계 (Design of Current Probe Using Faraday Effect of Optical Fiber)

  • 강항식;김철주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1278-1280
    • /
    • 1995
  • A probe type fiber-optic sensing techique for electric current measurement is applied in this paper. The technique is based on the Faraday effect which meaning is that polarization state of light is rotated by magnetic field. In experiment, test wire is located at inside and outside of the probe to be measured. The experimental results prove not only linear property, but also polarization rotation property according to the distance from outside of probe.

  • PDF

경사입사 증착방법을 이용한 선편광 방향변환기의 광학적, 물리적 특성 (Optical and structural properties of polarization-discriminatory state inverters with combination structure deposited by glancing angle deposition)

  • 박용준;;황보창권
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.409-410
    • /
    • 2009
  • In this paper, we report an experimental study of a linear polarization-discriminatory state inverter made of three-layer sculpture thin film fabricated by glancing angle deposition technique. The first and third layers are quarter-wave plates of zigzag structure and the middle of them is a circular Bragg reflector of left-handed helical structure.

  • PDF

Development of Polarization Controlled Micro Transmittance Profiler

  • An, Sung-Hyuck;Kim, Sang-Jun;Kim, Sang-Youl
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.998-1000
    • /
    • 2005
  • We report the development of the equipment that can measure the transmittance of the polarizer for TFTLCD application versus azimuth angle of the linear polarization at each micro spot in the section, and therefore measure the degree of iodine permeation and alignment quantitatively at each area of the section.

  • PDF

Phase Error due to Polarization Components of the Modified Triangular Interferometer

  • Kim, Soo-Gil
    • Journal of the Optical Society of Korea
    • /
    • 제11권1호
    • /
    • pp.10-17
    • /
    • 2007
  • We need two operation modes to obtain the complex hologram without bias and the conjugate image in the modified triangular interferometer (MTI). To solve the problem, we proposed the optimized MTI with one wave plate, which can obtain cosine and sine functions by the combination of one wave plate and one linear polarizer. In the extraction of phase term using the combination of polarization components, the phase error occurs, and we analyzed such potential phase errors in the optimized MTI.

유전체로 채워진 주기적인 슬롯을 갖는 평행평판 도파관 누설파 안테나의 해석 : E-편파 (Analysis of periodically slotted dielectrically filled parallel-plate waveguide as a leaky wave antenna : E-polarization case)

  • 이창원;조영기
    • 전자공학회논문지A
    • /
    • 제32A권7호
    • /
    • pp.30-35
    • /
    • 1995
  • Periodically slotted dielectrically filled paralled-plate waveguide as a leaky wave antenna is analysed for E-polarization case. The homogeneous linear equation whose unknown is the surface current density over the conducting strip is formulated, from which the complex propagation constant is calculated and compared with the previous results. Good correspondence between them is observed. And a method for the radiation pattern is also considered.

  • PDF

교외 및 주거 지역에서의 편파 다이버시티 전파전파 특성 연구 (A Study on the Propagation Characteristics of Polarization Diversity in rural and Residential Areas)

  • 임종태;김성진;유봉국
    • 한국전자파학회논문지
    • /
    • 제9권3호
    • /
    • pp.369-377
    • /
    • 1998
  • 본 논문에서는 편파 다이버시티에 대한 전파전파 특성 분석과 상용의 이동전화 기지국 시스템에 적용하기 위 한 가능성을 검증하였다. 이를 위하여 교외지역 및 주거지역을 대상으로 $\pm45^{\circ}$ 선형 편파특성을 가진 이중편파 안테나를 이용하였고, 다이버시티 이득(Diversity gain)과 상호상관계수(Cross correlation coefficients)의 관 점에서 기존의 공간 다이벼시티의 성능과 비교 분석하였다. 분석 결과 공간 다아버시티가 편파 다이버시티보다 1~2 dB 정도의 다이버시티 이득은 높게 나타났으며, 휴대용 이동전화 환경에서는 편파다이버시티와 공간다이 버시티 각각에 대한 상호 상관 계수는 그 차이가 $\pm0.1$ 이내로 큰 차이가 없음올 CDF(Cummulative Distrib bution Function) 분석을 통하여 확인할 수 있었다.

  • PDF

염화물 환경에 있는 에폭시도막철근의 부식 평가 연구 (Corrosion Evaluation of Epoxy-coated Bars in Chloride Contaminated Concrete Using Linear Polarization Tests)

  • 박영수;최경민;정시영;김병국;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.254-257
    • /
    • 2006
  • Five bench scale specimens were used to evaluate corrosion performance of damaged epoxy-coated bars in chloride contaminated concrete. The test specimens were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. Test results using linear polarization technique show that the current density of specimen with conventional steel becomes $0.715\;{\mu}A/cm^2$ indicating that the steel bars are in moderate or high corrosion condition. However, the corrosion rates of the specimens with damaged epoxy coated bars are much below $0.1\;{\mu}A/cm^2$ and the bars appears to be in passive condition. The corrosion protection performance provided by calcium nitrite is better than that of specimens with the other two inhibitors.

  • PDF

Ag 편광-광도핑에 의한 칼코게이나이드 박막의 광유기 복굴절 (The Photoinduced Birefringence of Chalcogenide Thin Film by the Ag Polarized-photodoping)

  • 장선주;박종화;박정일;정홍배
    • 한국전기전자재료학회논문지
    • /
    • 제14권2호
    • /
    • pp.139-144
    • /
    • 2001
  • In this study, we have investigated the photoinduced birefringence of Ag plarized-photodoping in double-layer of Ag doped chalcognide thin films and dependence of polarization states in chalcogenide thin films. Also, we have investigated the polarization dependence of photoinduced birefringence and the anisotropy of absorption in an amorphous As$\sub$40/Ge$\sub$10/Se$\sub$15/S$\sub$35/ chalcogenide thin films using two 632.8nm He-Ne lasers, which have a smaller energy than the optical energy gap (E$\sub$OP/) of the film, i.e., an exposure of sub-bandgap light (hν$\sub$op/). The photoinduced phenomena of Ag polarized-photodooping increasing the linear dichroism(d), about 84% and birefringence(Δn), about 23%. It will offer lots of information for the photodoping mechanism and analysis of chalcogenide thin films.

  • PDF

Optical Interferometry as Electrochemical Emission Spectroscopy of Metallic alloys in Aqueous Solutions

  • Habib, K.;AI-Mazeedi, H.
    • Corrosion Science and Technology
    • /
    • 제2권6호
    • /
    • pp.277-282
    • /
    • 2003
  • Holographic interferometry, an electromagnetic method, was used to study corrosion of carbon steel, aluminum and copper nickel alloys in NaOH, KCI and $H_2SO_4$ solutions respectively. The technique, called electrochemical emission spectroscopy, consisted of in-situ monitoring of changes in the number of fringe evolutions during the corrosion process. It allowed a detailed picture of anodic dissolution rate changes of alloys. The results were compared to common corrosion measurement methods such as linear polarization resistance measurements and electrochemical impedance spectroscopy. A good agreement between both data was found, thus indicating that holographic interferometry can be a very powerful technique for in-situ corrosion monitoring.