• Title/Summary/Keyword: linear plasma

Search Result 391, Processing Time 0.034 seconds

Thickness control of MoS2 by using O2 plasma (산소 플라즈마를 이용한 2차원 소재 MoS2의 두께제어 기술 연구)

  • Kim, Seo-Hyeon;Qua, Deshun;Ra, Chang-Ho;Yu, Won-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.289-290
    • /
    • 2014
  • Single layer $MoS_2$가 가지고 있는 전기적 특성, 광특성 등을 이용하기 위해 본 연구에서는 $O_2$ plasma를 이용해 경제적이며 효과적인 방법을 제시하고자 한다. 미세 etching을 통해 linear하게 thickness가 변화하는 것을 확인하고, pristine과 비슷하거나, 더 향상된 $MoS_2$를 제작하였다.

  • PDF

Study on Sustain Driving Waveform for Linear Gray Scale Expression in AC Plasma Display Panel (플라즈마 디스플레이 패널에서 선형적 계조 표현을 위한 유지 구동파형의 연구)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.255-260
    • /
    • 2014
  • A new sustain driving waveform and its implementation method is proposed to improve the gray scale linearity by applying the sustain waveform for producing the strong and weak discharge in AC plasma display panel. The driving method to express the gray scale of AC PDP is the combination of the several subfield in one TV frame, and the luminance of the each subfield is decided by the number of the sustain pulses. As the same amount of the strong plasma discharge is produced when the sustain pulses are applied during a sustain period, it looks easy to express the linear gray scale ideally. However, it is difficult to express the real linear gray scale due to the production of the address and first sustain discharge irrelevant to gray scale expression in every subfleld. Therefore, a new sustain driving waveformis adopted to produce partially the weak discharge instead of the strong discharge by the modification of the sustain pulses shape during the sustain period and the gray scale expression is close to the linearity.

Comparison of linear and non-linear equation for the calibration of roxithromycin analysis using liquid chromatography/mass spectrometry

  • Lim, Jong-Hwan;Yun, Hyo-In
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • Linear and non-linear regressions were used to derive the calibration function for the measurement of roxithromycin plasma concentration. Their results were compared with weighted least squares regression by usual weight factors. In this paper the performance of a non-linear calibration equation with the capacity to account empirically for the curvature, y = ax$^{b}$ + c (b $\neq$ 1) is compared with the commonly used linear equation, y = ax + b, as well as the quadratic equation, y = ax$^{2}$+ bx + c. In the calibration curve (range of 0.01 to 10 ${\mu}g/mL$) of roxithromycin, both heteroscedasticity and nonlinearity were present therefore linear least squares regression methods could result in large errors in the determination of roxithromycin concentration. By the non-linear and weighted least squares regression, the accuracy of the analytical method was improved at the lower end of the calibration curve. This study suggests that the non-linear calibration equation should be considered when a curve is required to be fitted to low dose calibration data which exhibit slight curvature.

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Investigation of the optimum condition for the quantitative analysis of Cu sample by Laser induced breakdown spectroscopy (구리 시료의 정량분석을 위한 LIBS의 최적조건 연구)

  • Kim, Seunghyun;Shin, Heesung;Ju, Junesik;Kim, Hodong
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • A laser induced breakdown spectroscopy (LIBS) measurement was carried out to derive an optimized measurement condition with a high reproducibility and to grow a plasma sphere to 20 mm high under a 600 mtorr vacuum in order to improve an accuracy of measurement. The measurement of the plasma was taken at a 6.0 mm distance, in the direction of a plasma sphere, from a sample. This location belongs to the outer sphere region in the plasma. The calibration curve of 'Ni' and 'Cu' was acquired by the signal intensity ratio and the atomic ratio for the samples, and linear regression of 'Cu' was $R^2$=0.9886, and the linear regression of 'Ni' was $R^2$=0.9988. The accuracy of LIBS was improved pre-existence as the measurement error of 'Ni' was 0.78%.

A Study of Plasma Heating High Voltage miliwave (플라즈마 가열용 대전력 미리파 장치 연구)

  • Kim, Won-Sop;Kim, Jeong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.522-522
    • /
    • 2007
  • We observed new physical phenomia. The dispersion relation and the distributions of RF electric field in the corrugated wall waveguide are analyzed numerically. The measurement of the dispersion relation are obsered by a plunger method employed in the slow wave structure for linear accelerators.

  • PDF

HPLC Analysis of Piroxicam in the Rabbit Plasma and its Bioavailability after the Transdermal Administration of Patches (토끼 혈장 중 피록시캄의 HPLC 분석 및 패취제 투여 후 경피흡수)

  • Shin, Dae-Hwan;Park, Seong-Hyeok;Lee, Gyeong-Bok;Lee, Chong-Kil;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of piroxicam in the rabbit plasma. After a treatment of plasma sample by liquid-liquid extraction, the drug was analyzed on an HPLC system with ultraviolet detection at 330 nm. HPLC was carried out using reversed-phase isocratic elution with a C18 column, a mobile phase of a mixture of acetonitril, doubly deionized water and acetic acid 43.74:56.00:0.26 v/v%) at a flow rate of 1.1 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma sample was linear over the concentration range of 0.01-2.0 ${\mu}$g/mL. The intra- and inter-day assay accuracies of this method ranged from 86.82% to 108.33% of normal values and the precision did not exceed 13% of relative standard deviation. The plasma concentration of piroxicam decreased to below the quantifiable limit at 12 hr after the i.v. bolus administration to rabbits following dose of 0.375 mg/kg yielding a apparen t plasma half life of 1.38 hr. The transdermal route prolongs plasma levels of piroxicam. The bioavailability, calculated from the dose-adjusted ratio of the $AUC_{transdermal}$ to the $AUC_{i.v.}$, was 7.44%. The plasma concentration of piroxicam was detected by 48 hr after the transdermal administration of patch at a dose of 32 mg/kg. This method was suitable for cutaneous absorption studies of piroxicam in the rabbit after transdermal administration of different types of dosages of the drug.

Association between the plasma concentration of melatonin and behavioral temperament in horses

  • Yubin Song;Junyoung Kim;Youngjae Park;Minjung Yoon
    • Journal of Animal Science and Technology
    • /
    • v.65 no.5
    • /
    • pp.1094-1104
    • /
    • 2023
  • Aggression in horses may cause serious accidents during riding and non-riding activities. Hence, predicting the temperament of horses is essential for selecting suitable horses and ensuring safety during the activity. In certain animals, such as hamsters, plasma melatonin concentrations have been correlated with aggressive behavior. However, whether this relationship applies to horses remains unclear. To address this research gap, this study aimed to evaluate differences in the plasma melatonin concentrations among horses of different breeds, ages, and sexes and examine the correlation between plasma melatonin concentrations and the temperament of the horses, including docility, affinity, dominance, and trainability. Blood samples from 32 horses were collected from the Horse Industry Complex Center of Jeonju Kijeon College. The docility, affinity, dominance, and trainability of the horses were assessed by three professional trainers who were well-acquainted with the horses. Plasma melatonin concentrations were measured using an enzyme-linked immunosorbent assay. The consequent values were compared between the horses of different breeds, ages, and sexes using a three-way analysis of variance and least significant difference post hoc test. Linear regression analysis was employed to identify the relationship between plasma melatonin concentrations and docility, affinity, dominance, and trainability. The results showed that the plasma melatonin concentrations significantly differed with breeds in Thoroughbred and cold-blooded horses. However, there were no differences in the plasma melatonin concentrations between the horse ages and sexes. Furthermore, plasma melatonin concentrations did not exhibit a significant correlation with the ranking of docility, affinity, dominance, and trainability.

Determination of Mertansine in Rat Plasma Using Liquid Chromatography-Tandem Mass Spectrometry and Pharmacokinetics of Mertansine in Rats

  • Choi, Won-Gu;Kim, Ju-Hyun;Jang, Hyun-Joon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.11 no.3
    • /
    • pp.59-64
    • /
    • 2020
  • Mertansine, a thiol-containing maytansinoid, is a tubulin inhibitor used as the cytotoxic component of antibody-drug conjugates for the treatment of cancer. Liquid chromatography-tandem mass spectrometry was described for the determination of mertansine in rat plasma. 50-μL rat plasma sample was pretreated with 25 μL of 20 mM tris-(2-carboxyethyl)-phosphine, a reducing reagent, and further vortex-mixing with 50 μL of 50 mM N-ethylmaleimide for 3 min resulted in the alkylation of thiol group in mertansine. Alkylation reaction was stopped by addition of 100 μL of sildenafil in acetonitrile (200 ng/mL), and following centrifugation, aliquot of the supernatant was analyzed by the selected reaction monitoring mode. The standard curve was linear over the range of 1-1000 ng/mL in rat plasma with the lower limit of quantification level at 1 ng/mL. The intra- and inter-day accuracies and coefficient variations for mertansine at four quality control concentrations were 96.7-113.1% and 2.6-15.0%, respectively. Using this method, the pharmacokinetics of mertansine were evaluated after intravenous administration of mertansine at doses of 0.2, 0.5, and 1 mg/kg to female Sprague Dawley rats.

Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma

  • Kong, Tae Yeon;Ji, Hye Young;Choi, Sang-Zin;Son, Miwon;Lee, Hye Suk
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.55-58
    • /
    • 2013
  • Dioscin is a biologically active steroidal saponin with anticancer and hepatoprotective effects. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for the quantification of dioscin in rat plasma. Dioscin was extracted from rat plasma using ethyl acetate at acidic pH. The analytes were separated on a Halo C18 column using gradient elution of acetonitrile and 0.1% formic acid and detected by tandem mass spectrometry in selected reaction monitoring mode. The standard curve was linear ($r^2$ = 0.998) over the concentration range of 1-100 ng/mL. The lower limit of quantification was 1.0 ng/mL using 50 ${\mu}L$ of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.3 to 8.0% and -5.4 to 10.0%, respectively. This method was applied successfully to the pharmacokinetic study of dioscin after oral administration of dioscin at a dose of 29.2 mg/kg in male Sprague-Dawley rats.