• Title/Summary/Keyword: linear parameters

Search Result 3,855, Processing Time 0.035 seconds

Accuracy Evaluation of Respiratory Air Flow Transducer for Artificial Ventilation (인공호흡시 호흡기류 계측 센서의 정확도 평가)

  • Lee, In-Kwang;Park, Mi-Jung;Kim, Kyoung-Ok;Shin, Eun-Young;Shon, Ho-Sun;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.425-431
    • /
    • 2015
  • Measurement accuracy was evaluated for the respiratory air flow transducer developed for applications under emergent situations. Pressure-Flow calibration equation was obtained by acquisition of air flow signals from the transducer in response to 6 flow waveforms, similar to those of artificial ventilation, generated by the standard flow generator system. Tidal volume and maximal flow rate were calculated on the flow signal then compared with the error-free data obtained by the linear displacement transducer of the flow generator system. Mean relative error of the tidal volume was within 3% and that of the maximal flow rate, approximately 5%, demonstrating accurate enough measurements. Therefore, the transducer could be applied to emergent situations to monitor the respiratory air flow signal as well as diagnostic parameters in real time.

Evaluation and Test Method Characterization for Mechanical and Electrical Properties in BGA Package (BGA 패키지의 기계적${\cdot}$전기적 특성 평가 및 평가법)

  • Koo Ja-Myeong;Kim Jong-Woong;Kim Dae-Gon;Yoon Jeong-Won;Lee Chang-Yong;Jung Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.289-299
    • /
    • 2005
  • The ball shear force was investigated in terms of test parameters, i.e. displacement rate and probe height, with an experimental and non-linear finite element analysis for evaluation of the solder joint integrity in area array packages. The increase in the displacement rate and the decrease in the probe height led to the increase in the shear force. Excessive probe height could cause some detrimental effects on the test results such as unexpected high standard deviation and probe sliding from the solder ball surface. The low shear height conditions were favorable for assessing the mechanical integrity of the solder joints. The mechanical and electrical properties of the Sn-37Pb/Cu and Sn-3.5Ag/Cu BGA solder joints were also investigated with the number of reflows. The total thickness of the intermetallic compound (IMC) layers, consisting of Cu6Sn5 and Cu3Sn, was increased as a function of cubic root of reflow time. The shear force was increased up to 3 or 4 reflows, and then was decreased with the number of reflows. The fracture occurred along the bulk solder, in irrespective of the number of reflows. The electrical resistivity was increased with increasing the number of reflows.

  • PDF

Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery (개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구)

  • Yu Mi;Kwon Eun-Ok;Choi Yun-Kyoung;Kang Hyun-Ju;Oh Se-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF

Bayesian quantile regression analysis of private education expenses for high scool students in Korea (일반계 고등학생 사교육비 지출에 대한 베이지안 분위회귀모형 분석)

  • Oh, Hyun Sook
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.6
    • /
    • pp.1457-1469
    • /
    • 2017
  • Private education expenses is one of the key issues in Korea and there have been many discussions about it. Academically, most of previous researches for private education expenses have used multiple regression linear model based on ordinary least squares (OLS) method. However, if the data do not satisfy the basic assumptions of the OLS method such as the normality and homoscedasticity, there is a problem with the reliability of estimations of parameters. In this case, quantile regression model is preferred to OLS model since it does not depend on the assumptions of nonnormality and heteroscedasticity for the data. In the present study, the data from a survey on private education expenses, conducted by Statistics Korea in 2015 has been analyzed for investigation of the impacting factors for private education expenses. Since the data do not satisfy the OLS assumptions, quantile regression model has been employed in Bayesian approach by using gibbs sampling method. The analysis results show that the gender of the student, parent's age, and the time and cost of participating after school are not significant. Household income is positively significant in proportion to the same size for all levels (quantiles) of private education expenses. Spending on private education in Seoul is higher than other regions and the regional difference grows as private education expenditure increases. Total time for private education and student's achievement have positive effect on the lower quantiles than the higher quantiles. Education level of father is positively significant for midium-high quantiles only, but education level of mother is for all but low quantiles. Participating after school is positively significant for the lower quantiles but EBS textbook cost is positively significant for the higher quantiles.

Performance Evaluation of a W-Band Waveguide Noise Measurement System for Calibrating Noise Sources (잡음원 교정용 W-대역 도파관 잡음 측정 시스템의 성능 평가)

  • Kang, Tae-Weon;Kim, Jeong-Hwan;Kwon, Jae-Yong;Kang, Jin-Seob
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.180-188
    • /
    • 2013
  • A W-band waveguide noise measurement system for calibrating noise sources was implemented and its basic characteristics were discussed. The measurement system consists of a commercial noise figure analyzer, a full W-band frequency converter, and a local oscillator. To measure the noise temperature of a noise source, the Y-factor method is generally used. Since the Y-factor method is based on the assumption that the receiving system is linear, linearity is one of important performance parameters of the measurement system. In this paper, the linearities for mixer, intermediate frequency(IF), and RF parts were evaluated to be 0.24 dB, 0.05 dB, and 0.20 dB, respectively. The noise figure of the measurement system evaluated is 5 dB to 17 dB in W-band. The measurement system can be used to measure thermal noise characteristics of electronic and electrical devices, equipments, and systems as well as to calibrate noise sources.

Relative Genetic Effects of Duroc and Taoyuan Breeds on the Economic Traits of Their Hybrids

  • Yen, N.T.;Tai, C.;Cheng, Y.S.;Huang, M.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.4
    • /
    • pp.447-454
    • /
    • 2001
  • For determining the relative genetic effects of Duroc (D) and Taoyuan (T) breeds on the economic traits of their hybrids, 72 litters of pigs, from four mating types, namely TT (T♂$\times$T♀), DD (D♂$\times$D♀) and D-T hybrids (TD, T♂$\times$D♀ and DT, D♂$\times$T♀) were used in this study. The various crossbreeding parameters were estimated by comparisons among mating types using linear contrasts of least-square analysis. The results of reproductive traits analysis showed that T breed had contributed superior genetic effects on the total number of piglets at birth (TBN) (p<0.10) and number of live piglets at 21 days (LP21) (p<0.05) to the D-T hybrids. Estimates of maternal genetic effects showed that the T females were superior in TBN (p<0.05), but inferior in average birth weight (ABW) and average litter birth weight (LBW) (p<0.01) to the D females. Direct heterosis effects were significant for LBW, LP21 and LWT21 (p<0.01). Least-squares analysis of other economic traits showed that T breed had relative negative effects on all growth traits, withers height (WH), body type index (BTI), average backfat thickness (ABF), carcass length (LENG), loin eye area (longissimus) (LEARA), and lean percentage (LEAN) of D-T hybrids (p<0.05). Estimates of direct genetic effects showed that the D breed was superior to the T breed in all growth and carcass traits except the average backfat (BF). Estimates of maternal genetic effects showed that average body weight at 180 days (WT180) of progenies from T sows were lighter than from D sows. Progenies from D females had larger and leaner carcass than those from T females. Direct heterosis effects were significant for average daily weight gains from 150 to 180 days ($ADG_{150-180}$) (p<0.05) and for average body weights at 150 (WT150), and 180 days (WT180), average daily weight gains from birth to 150 and 180 days ($ADG_{150}$ and $ADG_{180}$, respectively), WH, body length (BL), ABF, BTI, and LENG (p<0.01). The results showed that D-T hybrids tended to have superior TBN and LP21 than D breed, and to be superior in all growth and most conformation and carcass traits to the T breed.

Effects of Dietary Supplementation of Astaxanthin on Production Performance, Egg Quality in Layers and Meat Quality in Finishing Pigs

  • Yang, Y.X.;Kim, Y.J.;Jin, Z.;Lohakare, J.D.;Kim, C.H.;Ohh, S.H.;Lee, S.H.;Choi, J.Y.;Chae, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.7
    • /
    • pp.1019-1025
    • /
    • 2006
  • Two experiments were conducted separately to study the effect of astaxanthin on production performance and egg quality in laying hens and meat quality in finishing pigs. In Experiment 1, four hundred Brown Hy-Line layers, 26 weeks of age, were randomly divided into five treatments according to a single factorial arrangement. Each treatment had four replicates comprising 20 birds each. The dietary treatments were: 0, 0.7, 0.9, 1.1 and 1.3 ppm of astaxanthin fed for 14 days. Then all the birds were fed an astaxanthin-free diet (0 ppm astaxanthin) for an additional 7 days. The results showed that dietary astaxanthin had no significant effect on layer production performance. There was no significant effect (p>0.05) on egg weight, yolk height and Haugh unit (HU) with increasing dietary astaxanthin level and increased storage time. Yolk color was linearly increased (p<0.01) with the increasing dietary astaxanthin level and significantly decreased with the increasing storage time (p<0.05). The TBARS value in yolk decreased linearly (p<0.05) with increasing amount of dietary astaxanthin and storage time. When the diets were replaced with the astaxanthin-free feeds, all parameters concerning egg quality decreased with increasing days of measurement, especially the yolk color, and HU significantly decreased (p<0.05). In experiment 2, thirty-six barrows ($L{\times}Y{\times}D$), $107{\pm}3.1kg$ BW, were randomly divided into three treatments according to a single factorial arrangement. Each treatment had three replicates comprising 4 pigs each. The dietary treatments were: 0, 1.5 and 3.0 ppm of astaxanthin fed for 14 days. The results showed that dietary astaxanthin had no significant effects on production performance. There was a linear effect (p<0.05) on dressing percentage, backf.at thickness and loin muscle area with increasing dietary astaxanthin level. There were no significant effects (p>0.05) on the TBARS value, drip loss, meat color, marbling and $L^*$, $a^*$, $b^*$ values. Cholesterol concentration in meat was not affected by dietary addition of astaxanthin. It could be concluded that astaxanthin supplementation was beneficial to improve egg yolk color; egg quality during storage and it also could improve the meat quality of finishing pigs.

Determination of the Critical Buckling Loads of Shallow Arches Using Nonlinear Analysis of Motion (비선형 운동해석에 의한 낮은 아치의 동적 임계좌굴하중의 결정)

  • Kim, Yun Tae;Huh, Taik Nyung;Kim, Moon Kyum;Hwang, Hak Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.43-54
    • /
    • 1992
  • For shallow arches with large dynamic loading, linear analysis is no longer considered as practical and accurate. In this study, a method is presented for the dynamic analysis of shallow arches in which geometric nonlinearity must be considered. A program is developed for the analysis of the nonlinear dynamic behavior and for evaluation of critical buckling loads of shallow arches. Geometric nonlinearity is modeled using Lagrangian description of the motion. The finite element analysis procedure is used to solve the dynamic equation of motion and Newmark method is adopted in the approximation of time integration. A shallow arch subject to radial step loads is analyzed. The results are compared with those from other researches to verify the developed program. The behavior of arches is analyzed using the non-dimensional time, load, and shape parameters. It is shown that geometric nonlinearity should be considered in the analysis of shallow arches and probability of buckling failure is getting higher as arches are getting shallower. It is confirmed that arches with the same shape parameter have the same deflection ratio at the same time parameter when arches are loaded with the same parametric load. In addition, it is proved that buckling of arches with the same shape parameter occurs at the same load parameter. Circular arches, which are under a single or uniform normal load, are analyzed for comparison. A parabolic arch with radial step load is also analyzed. It is verified that the developed program is applicable for those problems.

  • PDF

Lipopolysaccharide-binding protein plasma levels as a biomarker of obesity-related insulin resistance in adolescents

  • Kim, Ki Eun;Cho, Young Sun;Baek, Kyung Suk;Li, Lan;Baek, Kwang-Hyun;Kim, Jung Hyun;Kim, Ho-Seong;Sheen, Youn Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.5
    • /
    • pp.231-238
    • /
    • 2016
  • Purpose: Lipopolysaccharide-binding protein (LBP) is a 65-kDa acute phase protein, derived from the liver, which is present in high concentrations in plasma. Data regarding the association between circulating plasma LBP levels and obesity-related biomarkers in the pediatric population are scarce. We aimed to determine whether there was a difference in plasma LBP levels between overweight/obese and normal-weight adolescents and to assess the correlation of circulating LBP levels with anthropometric measures and obesity-related biomarkers, including insulin resistance, liver enzyme levels, and lipid profiles. Methods: The study included 87 adolescents aged 12-13 years; 44 were overweight/obese and 43 were of normal-weight. We assessed anthropometric and laboratory measures, including body mass index (BMI), blood pressure, insulin resistance, liver enzyme levels, and lipid profiles. Plasma LBP levels were measured using an enzyme-linked immunosorbent assay. Results: The mean age of the participants was $12.9{\pm}0.3$ years. Circulating plasma LBP levels were significantly increased in overweight/obese participants compared with those in normal-weight participants ($7.8{\pm}1.9{\mu}g/mL$ vs. $6.0{\pm}1.6{\mu}g/mL$, P<0.001). LBP levels were significantly and positively associated with BMI, systolic blood pressure, aspartate aminotransferase, alanine aminotransferase, total cholesterol, low density lipoprotein-cholesterol, fasting glucose and insulin, and insulin resistance as indicated by the homeostatic model assessment of insulin resistance (HOMA-IR) (all P<0.05). In multivariate linear regression analysis, BMI and HOMA-IR were independently and positively associated with plasma LBP levels. Conclusion: LBP is an inflammatory biomarker associated with BMI and obesity-related insulin resistance in adolescents. The positive correlation between these parameters suggests a potentially relevant pathophysiological mechanism linking LBP to obesity-related insulin resistance in adolescents.

P Wave Detection Algorithm through Adaptive Threshold and QRS Peak Variability (적응형 문턱치와 QRS피크 변화에 따른 P파 검출 알고리즘)

  • Cho, Ik-sung;Kim, Joo-Man;Lee, Wan-Jik;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1587-1595
    • /
    • 2016
  • P wave is cardiac parameters that represent the electrical and physiological characteristics, it is very important to diagnose atrial arrhythmia. However, It is very difficult to detect because of the small size compared to R wave and the various morphology. Several methods for detecting P wave has been proposed, such as frequency analysis and non-linear approach. However, in the case of conduction abnormality such as AV block or atrial arrhythmia, detection accuracy is at the lower level. We propose P wave detection algorithm through adaptive threshold and QRS peak variability. For this purpose, we detected Q, R, S wave from noise-free ECG signal through the preprocessing method. And then we classified three pattern of P wave by peak variability and detected adaptive window and threshold. The performance of P wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. The achieved scores indicate the average detection rate of 92.60%.