• Title/Summary/Keyword: linear generator

Search Result 412, Processing Time 0.034 seconds

Implementation of Synchronized Stream Cryptosytsem for Secure Communication in Radio Channel (무선 채널에서의 암호 통신을 위한 동기식 스트림 암호시스템 구현)

  • 홍진근;손해성;황찬식;김상훈;윤희철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6A
    • /
    • pp.894-904
    • /
    • 1999
  • In this paper, a synchronized stream cryptosystem for secure communication in radio channel is designed and its security level is analyzed. The main parts of the proposed cryptosystem consist of synchronization pattern generator, session key generator, and key stream generator. The system performance is evaluated by analyzing the security level depending on the randomness, period, linear complexity, and correlation immunity. Experimental results with image data signal in the 10-1 and 10-2 channel error environment demonstrate the proper operation of the implemented crypto system.

  • PDF

Voltage Disturbance Generator for the Test of Custom Power Devices with Nonlinear Load Characteristics (비선형 부하특성을 갖는 전력품질 개선장치의 성능시험을 위한 전압변동발생기)

  • Park, S.D.;Lee, B.C.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.935-936
    • /
    • 2006
  • This paper deals with a 3-phase voltage disturbance generator. The proposed generator can be used for the performance teat of custom power devices with nonlinear load characteristics as well as linear load. The principle of the voltage sag, swell, outage, and unbalance generation is described. The switching pattern for the SCR thyristors in each mode is analysed to guarantee the system reliability. The validity of the proposed scheme is verified through simulation result.

  • PDF

A Fault Detection System Design for Uncertain Fuzzy Systems

  • Yoo, Seog-Hwan;Choi, Byung-Jae
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • This paper deals with a fault detection system design for uncertain nonlinear systems modelled as T-S fuzzy systems with the integral quadratic constraints. In order to generate a residual signal, we used a left coprime factorization of the T-S fuzzy system. From the filtered signal of the residual generator, the fault occurence can be detected effectively. A simulation study with nuclear steam generator level control system shows that the suggested method can be applied to detect the fault in actual applications.

An Application of Equivalent Magnetic Circuit method to the analysis of Claw-pole type generator (등가 자기회로법을 이용한 Claw-pole type generator의 특성해석)

  • Jung, Jae-Woo;Kwon, Soon-O;Lee, Sang-Ho;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.120-122
    • /
    • 2005
  • Magnetic field analysis of claw-pole type generator using equivalent circuit is presented in this paper. On the basis of 3D geometry and flux paths, equivalent magnetic circuit is designed and field analysis is performed by solving the circuit. Non-linear characteristic of material is considered for precise analysis results. 3D FEA is performed to verify analysis results, and flux densities in rotor and stator regions are compared. Calculated no-load back emf for field input voltage and speed are verified by experiment. Comparing to 3D FEA, presented method provides precise results with instant calculation time.

  • PDF

A Study for Development of Compact Powerpack used Hydrogen (수소를 연료로 하는 소형 파워팩 개발에 관한 연구(I))

  • Kim, Nam-Yuer;Kim, Gang-Chul;Lim, Ock-Taeck
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.4
    • /
    • pp.321-327
    • /
    • 2010
  • Current rechargeable battery cannot provide high energy density and the operational durations required. But linear engine/generators provide high energy density for portable power applications because fuel is more high density. In this paper, we suggest that basic design of powerpack using linear engine for assisting power output. Efficiency is relatively high because linear engine don't have crank mechanism compared with rotary engine. We made prototype engine and had experiments to know moving characteristic about the Linear Engine. It was possible to operate velocity at 50 Hz at the firing and pressure in cylinder was 16bar.

Layered Nonlinear feed-forward Sequence Generator (계층 구조의 비선형 피드포워드 수열 발생기)

  • 은유창;홍윤표;진석용;송홍엽
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5C
    • /
    • pp.595-600
    • /
    • 2004
  • In this paper, we propose a new simple scheme of layered nonlinear feedforward logic (NLFFL) overlaid on a linear feedback shift resistor (LFSR) to generate pseudonoise sequences, which have good balance property and large linear complexity. This method guarantee noiselike statistics without any designed connection scheme e.g. Langford arrangement.

A Study on the Encryption and Decryption Using Pseudo-Random One-Time Pad (의사 랜덤 one-time pad를 이용한 암호화 및 복호화에 관한 연구)

  • 허비또;조현묵;백경갑;백인천;차균현
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1991.10a
    • /
    • pp.100-102
    • /
    • 1991
  • In this paper, we use LFSR(Linear Feedback Shift Register) as a kind of pseudo-random one-time pad. Key generator is constructed using r separate LFSR's with IP(Irreducible Polynominal) which are relatively prime. Key generated in this method has high linear complexity. And also, file cryptosystem for file encryption and decryption is constructed.

Linear programming技法에 있어서 Basic Matrix의 Bartels-Golub Decomposition 및 그 응용

  • 문영현
    • 전기의세계
    • /
    • v.32 no.11
    • /
    • pp.664-669
    • /
    • 1983
  • 대규모 system을 취급하는 공학분야에 있어서 Matrix의 demension이 커짐에 따라 전산부담을 줄이기 위한 소요기억용량 절감 및 계산시간의 단축이 주된 관심사 중의 하나가 되어 왔다. LP(Linear Programming)기법 역시 대규모 선형 system에 적용될 경우 Basic Matrix 에 대한 dimensionality 문제를 포함하고 있으며 이에 대한 효과적인 해결방법으로 Bartels-Golub Decomposition 방법이 연구되어 있다. 이 방법은 Chan과 Yip등이 LSGA(Load Shedding and Generator Rescheduling) 문제에의 적용을 시도한 바 있으며, 일반적인 선형최적화 문제뿐만 아니라, dimensionality가 큰 Matrix의 Inverse 계산을 요하는 문제에 널리 적용될 수 있으므로 그 개요를 소개하고자 한다.

  • PDF

무효전력 최적제어에 의한 전력손실의 최소화

  • Lee, Hyeong-Gwan
    • ETRI Journal
    • /
    • v.6 no.4
    • /
    • pp.31-36
    • /
    • 1984
  • This paper presents an efficient method for real power loss minimization and for improvements in voltage profiles. This method is accomplished by optimal control of reactive power in the system. The problem is formulated as an optimization problem, suitable for solution by linear programming technique. After establishing the objective function for minimizing the system losses with the help of linearised sensitivity relationships of control variables, i. e., the transformer tap position, generator terminal voltages and switchable reactive power sources. The linear programming technique is used to determine the optimal adjustments to the above variables, simultaneously satisfying the constraints. The proposed algorithm has been tested on a sample system and the result is presented and discussed.

  • PDF

A evaluation of internal radial direction's distribution of MHD generator using shock tube (충격파관을 이용한 MHD발전기 내부 반경방향 분포의 평가)

  • 배철오;안병원;김윤식;이성근;박영산
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.2
    • /
    • pp.493-503
    • /
    • 2000
  • There are two types of generators in the MHD generation : linear type Faraday and disk type hall generator. In this paper, it is experimented disk type hall generator. Disk type generator is driven by shock tube that compresses working gas isentropically in a very short time. As a working gas, helium gas seeded with cesium is used. it is difficult to confirm the whole condition thorough oかy experiment because the things happened in MHD generator is very complex. Furthermore we can't how exactly what happen at the inside of generator's channel because the time of generation is very short and working gas flows out very high speed. Expecially it is almost impossible to measure the things occurred in the boundary layer using MHD generation experimental equipment driven shock uk. With above reasons, to know certainly how the several values happened inside disk MHD generator charge, some graphs were drawn linearly through calculation using measured experimental data. For the more, other calculated results which can't be obtained by only experiment are considered in this paper. And these calculated results are compared to experiment data how exactly done the calculation.

  • PDF