• Title/Summary/Keyword: linear dynamic range

Search Result 272, Processing Time 0.031 seconds

광대역 고감도 DLVA 개발

  • 이두훈;김상진;김재연;조현룡;이정문;김상기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.4
    • /
    • pp.39-52
    • /
    • 2000
  • A design of 2 stage S-DLVA(successive detector log video amplifier) was studied to detect wide dynamic radar pulse ranging from -70 ㏈m to 0㏈m. A basic design idea was focused on the linear detection in logarithmic scale of wide dynamic range radar pulses from nosie-like weak power of -70 ㏈m to relatively high power 0 ㏈m. It is highly formidable, since it requires high speed detection less than 10 nsec over the operating frequency ranges from 6 to 18 ㎓. A limiter diode, a tunnel diode and an L17-C were used as a protecting device, a detector diode and a log video amplifier in companion as a single stage detector to give voltage output proportional to the input power of about 35 ㏈ dynamic range. A protype of 2-stage DLVA having one more single stage detector was fabricated with a 32 ㏈ low noise amplifier and a 3 ㏈ hybrid coupler to provide total 70 ㏈ dynamic range detection. The logging characteristics were measured to have log slope of 25m.V/㏈ against 70 ㏈ logging range from -55 ㏈m to +15 ㏈m, the log linearity of within +/- 1.5 ㏈, and tangential sensitivity was at -63 ㏈m. The pulse dynamics of rise time and recovery time were measured as 50 nsec and 1.2 $\mu$sec, respectively. The reason might be due to the parasitic capacitances of packaged limiter, tunnel diode, and L17-C.

  • PDF

Analysis of the linear Amplifier/Analog-Digital Converter Interface in a Digital Microwave Wideband Receiver (디지털 광대역 마이크로 웨이브 수신기에서의 선형 증폭기와 ADC 접 속의 해석)

  • 이민혁;장은영
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.110-113
    • /
    • 1998
  • An analysis of the relationship between a linear amplifier chain and an analog-to-digital converter(ADC) in a digital microwave widevand receiver, with respect to sensitivity and dynamic range issues, is presented. The effects of gain, third-order intermodulation products and ADC characteristics on the performance of the receiver are illustrated and design criteria for the linear amplifier chain given a specified ADC are developed. A computer program is used to calculate theretical receiver performance based on gain and third-order intermodulation product selections. Simulated results are also presented and compared with theoretical values.

  • PDF

A Study on the Behaviour of Nonlinear Dynamic Absorber (비선형 동흡진기의 동적 거동에 관한 연구)

  • 박철희;송석홍;신현재;홍성철
    • Journal of KSNVE
    • /
    • v.3 no.2
    • /
    • pp.137-143
    • /
    • 1993
  • The conventional dynamic vibration absorber is very efficient in inhibiting the vibration of a machine. This is accomplished by "tuning" the absorber to the frequency of the harmonic disturbing force. If, however, the frequency of the disturbing force varies over a tuning frequency range in the normal operation of the system, the linear dynamic absorber may become inoperative and might aggravate matters particularly. This study is to endow the dynamic absorber with greater flexibility in suppressing vibrations throught a range of frequencies of the disturbing force. By introducing springs with nonlinear characteristics into its design, the results can be obtained. In this paper, the machine and the absorber were modelled as a nonlinear two-degree-of freedom system. And the concepts of nonlinear normal mode were adopted to obtain this purpose.s purpose.

  • PDF

On-Line Measurement System for the Determination of Chemical Oxygen Demand (화학적 산소 요구량 측정을 위한 On-Line 측정 시스템에 관한 연구)

  • 정형근;차기철
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.203-208
    • /
    • 1998
  • A simple on-line measurement system consisting of a conventional peristaltic pump, a HPLC-type heater, and a flow-through spectrophotometer is introduced for the determination of chemical oxygen demand(CODI. The system was configured such that the reaction mixture in the highly concentrated surffuric acrid medium flowing through the PTFE reaction tubing was heated at 150℃ and the absorbance of dichromate was continuously moutored at 445 m. The same addation principle as in the standard procedure was employed akcept the use of CoSO4 as a new effective catalyst. To test the system, potassium hydrogen phthalate was selected as a COD standard material. With suitably optimized reaction condition, the applicable concentration range depends on the concentration of potassium dichromate in the oxidizing reagent. With 2.0×10-3 M and 5.0×10-4M dichromate, the linear dynamic range was observed up to 400 ppm and 100 ppm, respectively. The standards in the Unear ranges were shown to be completely oxidized, which was confirmed with sodium oxalate or Mohr's salt. In all cases, the typical reproduclbility for betweenruns was 2% or less. The proposed measurement system provides the valuable in- formation for the further development of automated analysis system based on the present standard procedure.

  • PDF

Enhanced Fast Luma Adjustment for High Dynamic Range Television Broadcasting (고-휘도 텔레비전 방송을 위한 개선된 빠른 휘도 조절 기법)

  • Oh, Kyung Seok;Kim, Yong-Goo
    • Journal of Broadcast Engineering
    • /
    • v.23 no.2
    • /
    • pp.302-315
    • /
    • 2018
  • Highly non-linear electro-optical transfer function of the Perceptual Quantizer was approximated by a truncated Taylor series, resulting in a closed form solution for luma adjustment. This previous solution is fast and quite suitable for the hardware implementation of luma adjustment, but the approximation error becomes relatively large in the range of 600~3,900 cd/m2 linear light. In order to reduce such approximation error, we propose a new linear model, for which a correction is performed on the position and the slope of line based on the scope of approximation. In order to verify the approximation capability of the proposed linear model, a comparative study on the luma adjustment schemes was conducted using various high dynamic range test video sequences. Via the comparative study, we identified a significant performance enhancement over the previous fast luma adjustment scheme, where a 4.65dB of adjusted luma t-PSNR gain was obtained for a test sequence having a large portion of saturated color pixels.

Nonlinear Aeroelastic Characteristics of Composite Wing with Flap (복합재 플랩 날개의 비선형 공력탄성학 해석)

  • Shin, Won-Ho;Bae, Jae-Sung;Lee, In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.253-256
    • /
    • 2005
  • Nonlinear aeroelastic analyses of composite wing with flap are performed considering free-play and dynamic stiffness of actuator. Doublet-Hybrid method is used for the calculation of subsonic unsteady aerodynamic forces. Free-play is modeled as an asymmetric bilinear spring and is linearized by using the describing function method. The linear and nonlinear flutter analyses show that the flutter characteristics are significantly dependent on the free-play and dynamic stiffness. From the nonlinear flutter analysis, various types of limit cycle oscillations are observed in a range of air speeds below or above the linear divergent flutter boundary.

  • PDF

Design and Dynamic Analysis of Permanent Magnet Linear Synchronous Machine for Servo Application (서보 시스템 적용을 위한 직선형 영구자석 동기 전동기의 설계 및 동특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Jang, Won-Bum;Park, Ji-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.135-137
    • /
    • 2005
  • In servo system demanding precision dynamic characteristics, application of the Permanent Magnet Linear Synchronous Machines (PMLSM) has advantage of analysis convenience by simple geometry and thrust ripple reduction from the sinusoidal back electromotive force and excited stator. Therefore, this paper presents design of surface-mounted PMLSM with slotless iron cored stator according to coil turns to satisfy the rate thrust. Also, from dynamic analysis for servo application of manufactured motor with heavy mass, we offer accurate range of the DC link voltage and acceleration in rate speed. This is applied to speed reference profile considering system characteristics in total length of moving position.

  • PDF

Amperornetric Determination of Ascorbic Acia at a Thin Layer Flow Cell

  • Hahn, Young-Hee
    • Archives of Pharmacal Research
    • /
    • v.11 no.1
    • /
    • pp.56-60
    • /
    • 1988
  • A thin layer flow cell with cell volume of $8\;{\mu}{\ell}$ was constructed. Diffusion currents of ascorbic acid was directly proportional to the 1/3 power of volume flow rates. A linear dynamic range was obtained at the concentration range between $10^{-7}\;M\;and\;10^{-4}\;M$ of ascorbic acid with a detection limit of $10^{-8}\;M$. Ascorbic acid in the multivitamin product was amperometrically determined at TLFC after simply dissolving mg range ground product in $100m{\ell}$ of pH 7.0 phosphate buffer.

  • PDF

Dynamic Earth Pressure on Embedded Structure

  • Sadiq, Shamsher;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.9
    • /
    • pp.13-19
    • /
    • 2019
  • Dynamic earth pressure is considered an important parameter in the design of embedded structures. In current engineering design simplified methods developed either for yielding or non-yielding structures are utilized to predict resultant dynamic pressure. The applicability of these equations to embedded structures have not yet been reported. In this study we perform a suite of equivalent linear time history analysis for a range of embedded structure configurations. Numerically calculated dynamic pressure is shown to depend on the flexibility ratio (F), aspect ratio (L/H) of the embedded structure, and ground motion. Increase in L/H and intensity increases the magnitude of dynamic pressure. An increase in F decreases the dynamic pressure. Overall, the trends highlight the need for development of new method that accounts for F and L/H to calculate the dynamic pressure for the performance-based design of embedded structures.

A study of dynamic peoperties in cyclic simple shear test (동적단순전단 시험기를 이용한 매립지반 거동특성에 관한 연구)

  • Kim, Sung-Jin;Ryu, Jeong-Ho;Park, Yo-Hwan;Kim, Jin-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1422-1430
    • /
    • 2008
  • Cyclic simple shear test apparatus was used to investigate the dynamic response of liquefiable soils as reclamation material. The specimen were reclamation using simple air-pluviation method. The confining stress was applied the range of 100 kpa to 200 kpa. The resulted strain was in the range of $10^{-3}$ ~ 5 %. Based on these test results modulus reduction curve, damping curve and cyclic strength curve were developed. The developed curves were compared to those already available in literature. The obtained curves can be applied to FEM or equivalent linear analysis such as SHAKE for ground response analysis.

  • PDF