• Title/Summary/Keyword: linear assay

Search Result 272, Processing Time 0.03 seconds

Validation of Analytical Methods for Plasma Total Antioxidant Capacity by Comparing with Urinary 8-Isoprostane Level

  • Lee, Sang Gil;Wang, Taoran;Vance, Terrence M.;Hurbert, Patrice;Kim, Dae-Ok;Koo, Sung I.;Chun, Ock K.
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.2
    • /
    • pp.388-394
    • /
    • 2017
  • Although several analytical methods for measuring total antioxidant capacity (TAC) have been applied to biological samples, there were often dissimilar results due to the different principles of methods applied. Thus, this study aimed to validate four conventional analytical methods for measuring plasma TAC, including the ABTS assay, DPPH assay, FRAP assay, and ORAC assay, by comparing with urinary 8-isoprostane concentration. In addition, TAC results were compared with antioxidant enzyme activities including superoxide dismutase (SOD) and glutathione peroxidase in erythrocyte, and catalase in plasma. Plasma TAC measure by ABTS assay was strongly correlated with the result by FRAP assay. Plasma TAC by FRAP and ORAC assays were negatively correlated with erythrocyte SOD activity. The agreement among the four TAC assay methods and 8-isoprostane was determined using 95% prediction limits of linear regression, expressed as the mean of 8-isoprostane ${\pm}95%$ prediction limits. The ABTS method better agreed with 8-isoprostane than the other methods, demonstrating narrow prediction of limits. Furthermore, only plasma TAC determined by the ABTS assay was inversely correlated with urinary 8-isoprostane (r = -0.35, p < 0.05). In summary, the ABTS assay would be an appropriate method to measure overall plasma antioxidant capacity and predict the body's antioxidant status.

A Study on the Quality Control of 2-site Immunoradiometric Assay of Serum Ferritin (혈청(血淸) ferritin 측정(測定)의 정도관리(精度管理)에 관(關)한 고찰(考察))

  • Kim, Byoung-Kook;Seo, Il-Tack;Kim, Kwang-Won;Cho, Bo-Yeon;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.9-16
    • /
    • 1980
  • A 2-site immunoradiometric assay for serum ferritin was evaluated with commercially available kit. The assay required 6 hours. The slope of the standard curve kept up ideal range with the calculation of maxium binding instead of total dose until expire date. The stage II washing was more important than the stage I washing on the modified washing procedure as the bead keeping to remain in the tube. With this modified mothod, three times of tube. washing was sufficient to reduce the significant errors The measured values of serially diluted sample with standard diluting buffer was proportional to the predicted values. In the experiment of serum effect on the assay. a linear relationship from 5 to 50% serum, but beyond 50% there was reduction in measured ferritin concentration. It has a sensitivity of 2.77 ng/ml, within-assay precision (CV) of 8.0%, and between-assay reproducibility(CV) of 7.4% (mean 174.8 ng/ml).

  • PDF

Rapid Quantification of Topotecan in Biological Samples by Liquid Chromatography/Tandem Mass Spectrometry

  • Shin, Beom-Soo;Lee, Mann-Hyung;Yoo, Sun-Dong
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.5
    • /
    • pp.367-372
    • /
    • 2009
  • A rapid liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay method was developed for the determination of topotecan levels in rat serum. The assay utilized a single liquid-liquid extraction with a mixture of ethy l acetate and acetonitrile (6:1 v/v) and isocratic elution. The multiple reaction monitoring was based on the transition of m/z 422.0$\rightarrow$376.5 for topotecan and 315.1$\rightarrow$226.6 for clomipramine (internal standard). The developed assay was validated to demonstrate the specificity, recovery, lower limit of quantification (LLOQ), accuracy and precision. The assay was linear over a concentration range from 0.5-100 ng/mL, with LLOQ being 0.5 ng/mL using a small volume of rat serum (0.1 mL). The mean intra- and inter-day assay accuracy was 87.7-111.0% and 97.8-108.3, respectively, and the mean intra- and interday precision was between 1.6-4.3% and 3.8-10.3, respectively. The developed assay was applied to a pharmacokinetic study after a bolus i.v. injection of topotecan in rats.

Detection of DNA Damage in Carp Using Single-Cell Gel Electrophoresis Assay for Genotoxicity Monitoring

  • Jin, Hai-Hong;Lee, Jae-Hyung;Hyun, Chang-Kee
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.268-275
    • /
    • 2004
  • To investigate the potential application of the single-cell gel electrophoresis (SCGE) assay to carp as an aquatic pollution monitoring technique, gill, liver, and blood cells were isolated from carp exposed to a direct-acting mutagen, N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), or indirect mutagen, $benzo[\alpha]pyrene$ $(B[\alpha]P)$, then the DNA strand breakage was analyzed using the assay. Based on testing 5 different cell isolation methods and 6 electrophoretic conditions, the optimized assay conditions were found to be cell isolation by filter pressing and electrophoresis at a lower voltage and longer running time (at 0.4 V/cm for 40 min). In preliminary experiments, gill and liver cells isolated from carp exposed to MNNG in vitro exhibited DNA damage signals even with 0.5 ppb exposure, which is a much higher dose than previously reported. In the gill cells isolated from carp exposed to 0.01-0.5 ppm MNNG in vivo, significant dose-and time-dependent increases were observed in the tail for 4 days. As such, the linear correlation between the relative damage index (RDI) values and time for each dose based on the initial 48-h exposure appeared to provide effective criteria for the genotoxicity monitoring of direct-acting mutagenic pollution. In contrast, the in vivo exposure of carp to 0.25-1.0 ppm of $B[\alpha]P$ for 7 days resulted in dose-and time-dependent responses in the liver cells, in which 24-h delayed responses for metabolizing activation and gradual repair after 48 h were also observed. Thus, the negative-sloped linear correlation between the RDI and time at each dose based on the initial 48 h appeared to provide more effective criteria for the genotoxicity monitoring of indirect mutagenic pollution.

An Improved, Reliable and Practical Kinetic Assay for the Detection of Prekallikrein Activator in Blood Products

  • Shin, In-Soo;Shim, Yun-Bo;Hong, Choong-Man;Koh, Hyun-Chul;Lee, Seok-Ho;Hong, Seung-Hwa
    • Archives of Pharmacal Research
    • /
    • v.25 no.4
    • /
    • pp.505-510
    • /
    • 2002
  • An improved kinetic assay for prekallikrein activator (PKA), a potential vasodilator, has been developed to be used as an indicator for quality control during production of human albumin preparations. It consists of two reaction stages. In the first stage, PKA and prekallikrein are incubated at $37^{\circ}C$ for 45 min to allow the transformation into kallikrein. Kallikrein, a serine protease, catalyzes the splitting of p-nitroaniline (pNA) from its substrate H-D-Pro-Phe-Arg-pNA(S-2302). The rate at which pNA is released was measured spectrophotometrically at 405 nm. Prekallikrein, a substrate of PKA was purified by DEAE ion-exchange chromatography and the major potential variations in the assay were optimized; pH 8.0 and 150 mM sodium chloride were chosen to give a proper ionic strength. Reaction times in the range of 10 to 360 min provided linear dose-response curves. The concentration of prekallikrein was adjusted to fall between 1:1 and 1:3 dilutions to generate a linear standard calibration curve. Under the optimized conditions, reproducibility was checked. In a precision test, the coefficient of variation (CV) stayed within ${\pm}4%$ and the dose-response curve showed a good correlation (${r^2}=0.999$). An accuracy test with an international standard of PKA afforded a mean recovery of 97.5%.

Radiation exposure dose in human blood lymphocytes as assessed by the CBMN assay

  • Ryu, Tae Ho;Kim, Jin-Hong;Kim, Jin Kyu
    • Journal of Ecology and Environment
    • /
    • v.37 no.4
    • /
    • pp.195-200
    • /
    • 2014
  • The chances of accidental exposure are augmented as the application of ionizing radiation increases in various fields. Such accidental exposures may occur at nuclear power plants, laboratories, and hospitals. Cytogenetic assays have been used for estimating radiation dose in the situation of the accidents. The micronucleus assay has several advantages over the other cytogenetic methods as it is simple and fast. The present study aimed at investigation of the micronuclei frequencies in cytokinesis-block cells in human blood lymphocytes after ${\gamma}$-irradiation and at establishment of a standard dose response relationship. The samples of peripheral blood were obtained from 6 different donors aged between 24 and 30 years old. The bloods were irradiated in vitro with 0-5 Gy. A linear quadratic dose-response equation was obtained by scoring the micronuclei in binucleated cells; $y=27.87x^2+46.13x+2.08$ ($r^2=0.99$). Irradiation caused a significant decrease in the nuclear division index. Necrotic and apoptotic cells increased in number after irradiation in a dose-dependent manner. In conclusion, the conventional cytokinesis-block micronucleus assay has proven to be the great technique in biological dosimetry. Dose-response calibration curve derived from CMBN assay could be used to estimate the exposure dose during a radiological emergency.

Homogeneous Enzyme-Linked Binding Assay Mediated by the Interaction of Avidin with Biotin: Mistletoe Lectin I Assay

  • Rhee Paeng, In-Suk;Lee, Eun-Ah;Kim, Hyun-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.115-118
    • /
    • 2004
  • We have examined the feasibility of using the specific interaction between mistletoe lectin I (ML I) and ${\beta}$-Dgalactose instead of the anti-ML I antibody in developing a homogeneous type competitive binding assay for ML I. We also have examined the feasibility of adapting the biotin/avidin mediated homogeneous assay for this system. Alkaline phosphatase (AKP) was employed as a single substrate enzyme label. The dose-response curve shows a detection range of 1-25 ${\mu}$g/mL and a linear response with a correlation coefficient of 0.99. To demonstrate the analytical utility of this method, 10 ${\mu}$g/mL of ML I was spiked into distilled water. The results show that the mean recovery was 10.03 ${\mu}$g/mL with an SD of 0.18. The difference between the spiked value and the mean recovery was 0.03 ${\mu}$g/mL, with a relative error of 0.3 and 1.6 % of RSD.

Radioprotective effects of delphinidin on normal human lung cells against proton beam exposure

  • Kim, Hyun Mi;Kim, Suk Hee;Kang, Bo Sun
    • Nutrition Research and Practice
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: Exposure of the normal lung tissue around the cancerous tumor during radiotherapy causes serious side effects such as pneumonitis and pulmonary fibrosis. Radioprotectors used during cancer radiotherapy could protect the patient from side effects induced by radiation injury of the normal tissue. Delphinidin has strong antioxidant properties, and it works as the driving force of a radioprotective effect by scavenging radiation-induced reactive oxygen species (ROS). However, no studies have been conducted on the radioprotective effect of delphinidin against high linear energy transfer radiation. Therefore, this study was undertaken to evaluate the radioprotective effects of delphinidin on human lung cells against a proton beam. MATERIALS/METHODS: Normal human lung cells (HEL 299 cells) were used for in vitro experiments. The 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT) assay assessed the cytotoxicity of delphinidin and cell viability. The expression of radiation induced cellular ROS was measured by the 2'-7'-dicholordihydrofluorescein diacetate assay. Superoxide dismutase activity assay and catalase activity assay were used for evaluating the activity of corresponding enzymes. In addition, radioprotective effects on DNA damage-induced cellular apoptosis were evaluated by Western blot assay. RESULTS: Experimental analysis, including cell survival assay, MTT assay, and Western blot assay, revealed the radioprotective effects of delphinidin. These include restoring the activities of antioxidant enzymes of damaged cells, increase in the levels of pro-survival protein, and decrease of pro-apoptosis proteins. The results from different experiments were compatible with each to provide a substantial conclusion. CONCLUSION: Low concentration ($2.5{\mu}M/mL$) of delphinidin administration prior to radiation exposure was radioprotective against a low dose of proton beam exposure. Hence, delphinidin is a promising shielding agent against radiation, protecting the normal tissues around a cancerous tumor, which are unintentionally exposed to low doses of radiation during proton therapy.

Validation of One-Step Real-Time RT-PCR Assay in Combination with Automated RNA Extraction for Rapid Detection and Quantitation of Hepatitis C Virus RNA for Routine Testing in Clinical Specimens

  • KIM BYOUNG-GUK;JEONG HYE-SUNG;BAEK SUN-YOUNG;SHIN JIN-HO;KIM JAE-OK;MIN KYUNG-IL;RYU SEUNG-REL;MIN BOK-SOON;KIM DO-KEUN;JEONG YONG-SEOK;PARK SUE-NIE
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.595-602
    • /
    • 2005
  • A one-step real-time quantitative RT-PCR assay in combination with automated RNA extraction was evaluated for routine testing of HCV RNA in the laboratory. Specific primers and probes were developed to detect 302 bp on 5'-UTR of HCV RNA. The assay was able to quantitate a dynamic linear range of $10^7-10^1$ HCV RNA copies/reaction ($R^2=0.997$). The synthetic HCV RNA standard of $1.84{\pm}0.1\;(mean{\pm}SD)$ copies developed in this study corresponded to 1 international unit (IU) of WHO International Standard for HCV RNA (96/790 I). The detection limit of the assay was 3 RNA copies/reaction (81 IU/ml) in plasma samples. The assay was comparable to the Amplicor HCV Monitor (Monitor) assay with correlation coefficient r=0.985, but was more sensitive than the Monitor assay. The assay could be completed within 3 h from RNA extraction to detection and data analysis for up to 32 samples. It allowed rapid RNA extraction, detection, and quantitation of HCV RNA in plasma samples. The method provided sufficient sensitivity and reproducibility and proved to be fast and labor-saving, so that it was suitable for high throughput HCV RNA test.

A Colorimetric Microplate Assay Method for High Throughput Analysis of Lipase Activity

  • Choi, Suk-Jung;Hwang, Jung-Min;Kim, Sung-Il
    • BMB Reports
    • /
    • v.36 no.4
    • /
    • pp.417-420
    • /
    • 2003
  • The present work describes a colorimetric microplate assay for lipase activity based on the reaction between 5,5'-dithiobis(2-nitro benzoic acid) (DTNB) and the hydrolysis product of 2,3-dimercapto-1-propanol tributyrate (DMPTB). Reaction mixtures containing DTNB, DMPTB, and lipase were prepared in microplate wells, and the absorbance at 405nm was recorded after incubation at $37^{\circ}C$ for 30 min. A linear relationship was obtained in the range of 0.1-1 U of lipase activity by this method. The reaction conditions were also optimized for the range of 0.01-0.1 U or 1-10 U. When assaying crude tissue extracts, the reaction of DTNB with non-specific reducing agents created a major source of error. However, this error was corrected by the use of blank samples that did not contain DMPTB.