• 제목/요약/키워드: line-offset

검색결과 277건 처리시간 0.055초

1회선 송전선로 단락사고의 개선된 고장점 표정기법 (Enhanced Fault Location Algorithm for Short Faults of Transmission Line)

  • 이경민;박철원
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.955-961
    • /
    • 2016
  • Fault location estimation is an important element for rapid recovery of power system when fault occur in transmission line. In order to calculate line impedance, most of fault location algorithm uses by measuring relaying waveform using DFT. So if there is a calculation error due to the influence of phasor by DC offset component, due to large vibration by line impedance computation, abnormal and non-operation of fault locator can be issue. It is very important to implement the robust fault location algorithm that is not affected by DC offset component. This paper describes an enhanced fault location algorithm based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any erstwhile information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced fault location algorithm uses DFT filter as well as the proposed DC offset filter. The behavior of the proposed fault location algorithm using off-line simulation has been verified by data about several fault conditions generated by the ATP simulation program.

접원의 전방향 경로이동에 의한 오프셋 알고리즘 (An offset algorithm with forward tracing of tangential circle for open and closed poly-line segment sequence curve)

  • 윤성용;김일환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.1022-1030
    • /
    • 2003
  • In this paper we propose a efficient offset curve construction algorithm for $C^0$-continuous Open and Closed 2D sequence curve with line segment in the plane. One of the most difficult problems of offset construction is the loop problem caused by the interference of offset curve segments. Prior work[1-10] eliminates the formation of local self-intersection loop before constructing a intermediate(or raw) offset curve, whereas the global self-intersection loop are detected and removed explicitly(such as a sweep algorithm[13]) after constructing a intermediate offset curve. we propose an algorithm which removes global as well as local intersection loop without making a intermediate offset curve by forward tracing of tangential circle. Offset of both open and closed poly-line segment sequence curve in the plane constructs using the proposed approach.

  • PDF

직류옵셋제거필터에 의한 거리계전기법의 성능 개선에 관한 연구 (A Study on Performance Enhancement of Distance Relaying by DC Offset Elimination Filter)

  • 이경민;박유영;박철원
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.67-73
    • /
    • 2015
  • Distance relay is widely used for the protection of long transmission line. Most of distance relay used to calculate line impedance by measuring voltage and current using DFT. So if there is a computation error due to the influence of phasor by DC offset component, due to excessive vibration by measuring line impedance, overreach or underreach can be occurs, and then abnormal and non-operation of distance relay can be issue. It is very important to implement the robust distance relaying that is not affected by DC offset component. This paper describes an enhanced distance relaying based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any prior information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced distance relay uses fault current as well as residual current. The behavior of the proposed distance relaying using off-line simulation has been verified using data about several fault conditions generated by the ATP simulation software.

2선 단락 사고 시 자속상쇄형 한류기의 동작 특성 (Characteristics Operation of a Flux-offset Type Fault Current Limiter in a Double line-to-line Fault)

  • 최혜원;최효상
    • 공학기술논문지
    • /
    • 제7권3호
    • /
    • pp.131-135
    • /
    • 2014
  • In this paper was proposed a flux offset-type fault current limiter as means of reducing fault currents. To secure the operation reliability of a flux offset-type fault current limiter, constructed a simulation system to analyze its operation characteristics by generating a double line-to-line fault. According to the test results, the system performed stably without any impedance. However, when an accident occurred, the flux-offset of magnetic was not occurred. Because of this, any impedance occurred at circuit. It was confirmed that the impedance was low and fast to limit the fault current. At this time, the fault current limited rate was about 95%.

A Sweep-Line Algorithm and Its Application to Spiral Pocketing

  • EL-Midany, Tawfik T.;Elkeran, Ahmed;Tawfik, Hamdy
    • International Journal of CAD/CAM
    • /
    • 제2권1호
    • /
    • pp.23-28
    • /
    • 2002
  • This paper presents an efficient line-offset algorithm for general polygonal shapes with islands. A developed sweep-line algorithm (SL) is introduced to find all self-intersection points accurately and quickly. The previous work is limited to handle polygons that having no line-segments in parallel to sweep-line directions. The proposed algorithm has been implemented in Visual C++ and applied to offset point sequence curves, which contain several islands.

병행 2회선 송전선로의 개선된 거리계전기법 (Advanced Distance Relaying of on a Double Circuit Transmission Line)

  • 박철원
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.

병행 2회선 송전선로의 선간단락시 고장점 표정의 개선에 관한 연구 (A Study on Advanced Fault Locating for Short Fault of a Double Circuit Transmission Line)

  • 박유영;박철원
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.28-37
    • /
    • 2016
  • Fault locating is an important element to minimize the damage of power system. The computation error of fault locator may occur by the influence of the DC offset component during phasor extraction. In order to minimize the bad effects of DC offset component, this paper presents an improved fault location algorithm based on a DC offset removal filter for short fault in a double circuit transmission line. We have modeled a 154kV double circuit transmission line by the ATP software to demonstrate the effectiveness of the proposed fault locating algorithm. The line to line short faults were simulated and then collected simulation data was used. It can be seen that the error rate of fault locating estimation by the proposed algorithm decreases than the error rate of fault locating estimation by conventional algorithm.

머신 비전 라인 스캔 카메라를 위한 라인 스캔 광원의 제어 특성에 관한 연구 (A Study on the Control Characteristics of Line Scan Light Source for Machine Vision Line Scan Camera)

  • 김태화;이천
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.371-381
    • /
    • 2021
  • A machine vision inspection system consists of a camera, optics, illumination, and image acquisition system. Especially a scanning system has to be made to measure a large inspection area. Therefore, a machine vision line scan camera needs a line scan light source. A line scan light source should have a high light intensity and a uniform intensity distribution. In this paper, an offset calibration and slope calibration methods are introduced to obtain a uniform light intensity profile. Offset calibration method is to remove the deviation of light intensity among channels through adding intensity difference. Slope calibration is to remove variation of light intensity slope according to the control step among channels through multiplying slope difference. We can obtain an improved light intensity profile through applying offset and slope calibration simultaneously. The proposed method can help to obtain clearer image with a high precision in a machine vision inspection system.

CPW와 Offset 결합 전송선로를 이용한 비대칭 다단 분배기 (Unequal Multi-Section Power Divider using CPW and Offset Coupled Transmission Lines)

  • 최종운;윤영철;성규제;김영
    • 한국항행학회논문지
    • /
    • 제23권4호
    • /
    • pp.309-315
    • /
    • 2019
  • 본 논문은 1:3과 1:4 분배 비율을 갖는 비대칭 분배기를 CPW와 offset 결합 전송선로를 이용하여 다단 구조로 구현한 것이다. 이 분배기는 다단 구조의 전송선로와 캐패시터와 저항이 병렬로 연결된 회로로 구성되어 있다. 다단 전송선로는 임의의 임피던스로 종단된 ${\lambda}/4$ 단일 전송선로를 분해하여 그것을 $90^{\circ}$ 전기적 길이보다 짧은 다단 전송선로로 정합시키는 방법으로 구현하였고, RC 병렬회로는 출력 포트의 반사계수와 출력 포트 사이의 고립 특성을 얻기 위해서 전송선로 사이에 연결하였다. 이러한 방법으로 2 GHz에서 설계된 전력분배기는 각 단의 전송선로는 ${\lambda}/4$보다 짧게 구현되어 기존 것 보다 최소 27% 작게 구현하였고, 광 대역 특성을 얻을 수 있음을 확인하였다.

조선전용 3차원 CAD 시스템을 이용한 Pipe Offset Routing 프로그램 개발 (Pipe Offset Routing Program By Using 3D CAD For Shipbuilding)

  • 김성민;신동목
    • 대한조선학회논문집
    • /
    • 제45권4호
    • /
    • pp.432-440
    • /
    • 2008
  • Korean shipbuilders are starting to use three dimensional solid CAD systems to enhance their competitiveness in design and production. Despite many merits, three dimensional CAD systems reveal some problems in pipe-line modeling. Pipe-line modeling is heavily dependent on point data in routing. However, since the models built by sweeping or skinning operations do not have data about points and lines on the surfaces, the point data for routing are currently manually calculated by considering the diameters of the pipes and alignment conditions with other pipes. This process is inefficient and prone to errors. In order to enhance the pipe modeling, this paper presents an Offset Routing Program for a three dimensional CAD system, which aids designers to easily define the start points and to generate the pipe routings using reference objects.