• Title/Summary/Keyword: line sources

Search Result 621, Processing Time 0.03 seconds

A Study on the Performance of Optimization Techniques on the Selection of Control Source Positions in an Active Noise Barrier System (능동방음벽 시스템의 제어 음원 위치 선정에 미치는 최적화 기법 성능에 관한 고찰)

  • Im, Hyoung-Jin;Baek, Kwang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1012-1015
    • /
    • 2004
  • There have been several kinds of attempts to actively control the deflected noise behind the noise barrier. Omoto's work in 1993 would be one of the fundamental studies, where he placed the control sources uniformly parallel to the noise barrier. Following this study, Yang pointed that the average distance between the noise source and control sources is more important than the arrangement of control sources such as a straight line or an arc type distribution. In 2004, Baek tried to show optimal arrangement of control sources while keeping the average distance between the noise source and control sources. He used simulated annealing algorithm which is one of the natural algorithms for the selections of optimal control source positions, but the searching technique was a hybrid of the simulated annealing and the sequential searching to adapt to the vast amount of searching time. This study is about the performance comparison between the pure sequential searching and the hybrid one. The simulation results show very similar performance and a pure simulated annealing searching will be more beneficial for the noise reduction performance but at the cost of computing time.

  • PDF

Estimation of emission rate for railroad rolling stock sources in Busan Metropolitan City (부산광역시에서 철도차량 배출원에 의한 오염물질 배출량 산정)

  • 이화운;김유근;김희만;박종길;장난심;이희령
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.407-415
    • /
    • 2001
  • A case of air pollution study of estimation of emission rate for source to railroad rolling stock and emissive character about is unusual. Recent emission rate of railroad rolling stock was estimated with emission factor of EPA in three region(Seoul, Incheon, and Gyeonggido). But this EPA factor could be incorrect because Korea and America have a different railroad environment in the variety of fuel and character of railroad rolling stock In this study, emission rate of each line, car and region(district) with omission factor of Korean case(National Railroad Administration, 1997) was estimated. In Busan Metropolitan City, railroad rolling stocks were divided accoding to, each line, car and service. Particularly, the Idle fuel rate omitted in the preceding study was included in calculation fuel rate. Total emission rate of Busan Metropolitan City was 887.41 t/year Each emission rates of Kyeongbu line, Donghaenambu line, Gaya line, Uam line, Bujeon line, and idle was 489.15t, 196.46t, 33.94t, 12.66t, 6.47t, and 48.75t, respectively.

  • PDF

A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템)

  • Ji Jun-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF

Evaluation of the Influence of Inland Pollution Sources on Shellfish Growing Areas after Rainfall Events in Geoje Bay, Korea (강우에 따른 거제만해역 육상오염원의 영향평가)

  • Ha, Kwang-Soo;Yoo, Hyun-Duk;Shim, Kil-Bo;Kim, Ji-Hoe;Lee, Tae-Seek;Kim, Poong-Ho;Ju, Ja-Yeon;Lee, Hee-Jung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.6
    • /
    • pp.612-621
    • /
    • 2011
  • The influences of inland pollution sources because of rainfall events on the bacteriological water quality in Geoje Bay, a major shellfish production area in Korea, were investigated. The sanitary status of sea water and shellfish after rainfall events was also evaluated. The flow rates of 13 streams around Geoje Bay showed 6 to 7-fold increases after 15 to 21 mm of rainfall. Peak pollution was observed in the Naegan Stream, the Gandeok Stream and the Seojeong Stream. The calculated impact area of inland pollution sources was 3.1 $km^2$ immediately after 15 mm of rainfall and expanded to 3.5 $km^2$ after 24 hours. These calculations of impacted area matched results from fecal coliform analyses with sea water. The distance between the major pollution source in the bay (the Gandeok Stream) and the station with the worst bacteriological water quality immediately after 15 mm of rainfall, which was below the Korean standard, was 0.8 km in a straight line; this distance increased to 2.0 km after a period of 24 hours. The area impacted by inland pollution sources after a 15 mm rainfall event was wider than after a 21 mm rainfall. Although the flow rate from inland pollution sources was higher, the concentration of fecal coliform in the discharged water was lower after higher rainfall events. These observations corresponded with the results of fecal coliform analyses with sea water samples. According to the evaluation of the influences of inland pollution sources and fecal coliform analyses on sea water and shellfish samples in Geoje Bay, pollutants from inland sources did not reach the boundary line of the shellfish growing area after rainfall events of 15 or 22 mm. The bacteriological water quality of the shellfish growing area in Geoje Bay met the Korean standard and US NSSP requirements for approved shellfish growing areas.

AKARI DEEP FIELD SOUTH: SPECTROSCOPIC OBSERVATIONS OF INFRARED SOURCES

  • Sedgwick, Chris;Serjeant, Stephen;Pearson, Chris;Matsuura, Shuji;Shirahata, Mai;Matsuhara, Hideo;Marchetti, Lucia;White, Glenn J.;Vaccari, Mattia;Baronchelli, Ivano;Rodighiero, Giulia;Hadsukade, Bunyo;Clements, David L.;Amber, Simon
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.281-285
    • /
    • 2017
  • We present a summary of our spectroscopic redshift catalogue of 404 sources in the AKARI Deep Field South (ADF-S). We have used the AAOmega spectrograph to target mid-infrared and far-infrared sources selected primarily from AKARI observations in this field for which we were able to obtain optical counterparts. Our sources with identified redshifts include 316 with $H{\alpha}$ detections at $z{\leq}0.345$ and 15 sources at z > 1 with MgII or $Ly{\alpha}$ emission lines. About 13% of our $z{\leq}0.345$ sources are dominated by active galactic nuclei (AGN) emission, although many show emission from both star formation and AGNs. The median Balmer decrement is 5.9. Ultra-luminous infrared galaxies (ULIRGs) were found only in the higher-redshift sources. Optical and near infrared data will be available shortly, enabling calibration of the line luminosities and spectral energy distribution (SED) fitting for these sources.

A Study on Evaluation for Risk Level in Transmission Network Connected with Renewable Energy (신재생에너지 계통 연계에 따른 송전망 Risk Level 평가에 대한 연구)

  • Kim, Sung-Yul;Moon, Sang-Kun;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.87-95
    • /
    • 2011
  • A Renewable Portfolio Standard(RPS) is a regulation that requires the increased generation of energy from renewable energy sources such as solar, wind, fuel cell, small hydro, biomass and geothermal. By environmental, technical and these regulatory reasons, the amount of renewable energy sources will be increased in a network. However, it is hard to assess risk of a transmission network with large scale renewable energy sources because the output characteristics of renewable energies are intermittent. This paper evaluates effects of a transmission system with supplemental large scale renewable energies into the existing system. To evaluate these effects, a methodology for risk level of components in a network is proposed considering steady state and contingency N-1 in this paper. We consider line current and bus voltage in each state of a network.

The prediction of train interior noise with Statistical Energy Analysis (통계적 에너지 해석법을 이용한 전동차의 실내소음 분석)

  • Lee, Seoung-Woo;Kim, Jae-Chul;Lee, Dong-Hoon;Choo, Don-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1413-1419
    • /
    • 2008
  • As the improvements of service quality is becoming an important issue the, interior noise level of a train is an important factor of comfortable ride. To reduce the interior noise level, noise sources of the train need to be removed. However, in case with a structure of large scale and multiple noise sources, an estimation of influences of major noise sources, with indentification of its traveling paths needs to be performed. In current state, to improve the interior noise reduction, consideration of sound transmission loss of the train body prior to manufacturing is usually performed. In this study, the sound transmission loss of the train body of new model train of seoul metro's line no.2 under test opeation is measured and modeling of the train body is performed. And train interior noise is predicted using the measured values.

  • PDF

SCARA robot calibration on off-line programming (오프라인 프로그래밍에서 스카라 로봇의 보정)

  • Jung, Sung-Woo;Son, Kwon;Lee, Min-Chul;Choi, Jae-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1832-1835
    • /
    • 1997
  • Off-line programming systems are widely spread in assembly lines of minute electronic products to huge offshore structures. Any OLP system has to be calibrated before the on-line robot tasks are performed because there are inherent differences between the CAD model on OLP and the real robot workspace. This paper uses simple geometric expressions to propose a calibration method applicable to an OLP for SCARA robots. A positioning task on the two-dimensional horizontal surface was used in the error analysis of a SCARA robot and the anaysis shows that the inaccuracy results from the two error sources non-zero offset angles of two rotational joints at the zero return and differences in link lengths. Pen marks on a sheet of plotting paper are used to determine the accurate data on the joint centers and link dimensions. The calculated offset angles and link lengths are fed back to the OLP for the calibration of the CAD model of the robot and task environments.

  • PDF

PDR Model : Test and fit observed data Obtained by Herschel PACS

  • Yun, Hyeong-Sik;Lee, Jeong-Eun;Lee, Seokho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.81.1-81.1
    • /
    • 2014
  • We utilized a 2-D PDR code developed by Lee et al. (2014) to explore the observed OH line fluxes toward embedded protostars. This 2-D PDR code combines self-consistently the FUV radiative transfer, gas-energetics, chemistry, and line radiative transfer. We modeled two sources, GSS30-IRS1 and Elias29, which show conspicuous line emission in the Herschel/PACS wavelength range. The physical and chemical structure for a given embedded source was derived by fitting the PACS CO line fluxes. After exploring various parameter spaces, we conclude that IR-pumping effect either by the central IR source and dust in-situ is insignificant for OH emission, unlike previous studies. We here present a possible solution for the observed OH fluxes, which require a high OH abundance and temperature at the inner-part of the UV heated cavity wall.

  • PDF

The Coupling Analysis of Electromagnetic Wave to Transmission Line using Nonhomogeneous Differential Equations (비동차 미분 방정식을 이용한 외부전자파에 의한 전송선로 결합 해석)

  • Myung, Sung-Ho;Lee, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.552-556
    • /
    • 1989
  • The line equations can be expressed by a set of nonhomogeneous differential equation where forcing terms of these equations have been adopted. Equivalent-circuit representations of this paper are derived from solutions of the equations. The contribution of the external wave to the line is expressed in terms of ideal sources in the form of a cascade connection to the line. These representations art conveniently applicable to the various types of transmission lines because these Lines can often be written in the form of a chain matrix.

  • PDF