• 제목/요약/키워드: line source

검색결과 1,649건 처리시간 0.04초

GaAs에서의 Si의 확산기구와 그에 관련된 격자 결함 화학 (Diffusion Kinetics of Si in GaAs and Related Defect Chemistry)

  • 이경호
    • ETRI Journal
    • /
    • 제11권4호
    • /
    • pp.75-83
    • /
    • 1989
  • The diffusion mechanism of Si in GaAs was investigated using different diffusion sources based on the Si-Ga-As ternary phase equilibria. The Si profiles are measured with secondary ion mass spectrometry and differ significantly for sources taken from the different phase fields in the ternary phase diagram. Neutral As vacancy diffusion is proposed for acceptor Si diffusion anneals using a Ga - Si - GaAs source. Donor Si diffusion using As - rich sources and a Si -GaAs tie line source shows concentration dependent diffusion behavior. Concentration dependent diffusion coefficients of donor Si for As - rich source diffusion were found to be related to net ionized donor concentration and showed three regimes of different behavior: saturation regime, intermediate regime,and intrinsic regime. Ga vacancies are proposed to be responsible for donor Si diffusionin GaAs: $Si_Ga^+V_Ga^-$ (donor Si -acceptor Gavacancy) complex for the extrinsic regime and neutral $V_G$a, for the intrinsic regime.The Si - GaAs tie line source resulted in two branch profiles, intermediate between the As - rich and the Ga - rich source diffusion cases.

  • PDF

스톡스 유동장 내의 한 쌍의 소오스-싱크에 의한 자유표면 유동해석 (Analysis on the free surface flow induced by a pair of source-sink in Stokes flow)

  • 정재택;박종선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.304-307
    • /
    • 2008
  • Two-dimensional Stokes flow due to the line source and line sink of same strength in semi-infinite flow region with free surface is analysed using complex variable theory and conformal mapping. Surface tension effects are included while gravity is neglected. From the results of analysis, flow pattern and free surface shape are obtained and velocity distribution on the free surface is determined with 2 independent parameters Ca (capillary number) and h (non-dimensionalized distance between source and sink). When the location of the sink is above the source, velocity on the free surface converges and a cusp occurs on the free surface for the value of Ca above some critical capillary number.

  • PDF

자기단 전원임피던스 추정을 이용한 송전선 고장점표정 알고리즘 (Transmission Line Fault Location Algorithm Using Estimated Local Source Impedance)

  • 권영진;김수환;강상희
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.885-890
    • /
    • 2009
  • A fault location algorithm using estimated local source impedance after a fault is proposed in this paper. The method uses after fault data only at the local end. It uses the negative sequence current distribution factor for more accurate estimation. The proposed algorithm can keep up with the variation of the local source impedance. Therefore, the proposed algorithm especially is valid for a transmission line interconnected to a wind farm that the equivalent source impedance changes continuously. The performance of the proposed algorithm was verified under various fault conditions using the Simpowersystem of MATLAB Simulink. The proposed algorithm is largely insensitive to the variation in fault distance and fault resistance. The test results show a very high accurate performance.

차패턴을 갖는 선전원 배열 안테나 합성을 위한 새로운 방법 (A New Method for Synthesis of Line Source Array Antennas with Difference Patterns)

  • 송창현;전상재;박의준
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.357-360
    • /
    • 2005
  • In the synthesis of the continuously distributed line source antennas with arbitrary patterns, the formulas of Taylor sum pattern and Bayliss difference pattern have been mainly used. In this paper, an optimization scheme is newly presented to directly synthesize the desired difference patterns from Taylor line source formula, and then the distributions are numerically adapted to the specified difference patterns by using an appropriate iterative sampling method.

  • PDF

왕복동 압축기의 소음 및 진동 기여도 분석 (Coherence Analysis of Noise and Vibration For Reciprocating Compressor)

  • 이대성;황원걸;이유엽;임형은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.875-880
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor. Through the use of multiple-input/single-output(MISO) mode1, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. As outputs, vibrations of compressor shell were measured at three positions; cylinder head, one near the suction line, and the top of upper shell. The partial coherence function and transfer function are obtained ken the measured data, and the results are observed in order to determine vibration source and its influence on the shell vibration.

  • PDF

콘버어터의 전원 고조파분을 저감시키기 위한 SHE PWM 방식의 적응 (Application of SHE PWM Scheme for Reducing The Source Harmonic Components of Converter)

  • Chung, Dong-Hwa
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1427-1435
    • /
    • 1990
  • This paper proposes the Selected Harmonic Elimination Pluse Width Modulation (SHE PW) scheme toreduce the ahrmonic components of source line current. To eliminate the low order harmonics which affects the source dominatly, we apply the Fourier series analysis to line current waveforms and then find out the switching patterns using the SHE PWM scheme. In addition to the analysis of harmonic effects, the three phase filter circuit is used to reduce high order harmonics. For the experimental realization, the converter circuit with power Transistor(PTR) is designed and the Pulse Time Control(PTC) is applied. The line current and the load voltage are measured under the condition of three phase application, highly inductive load.

  • PDF

박막트랜지스터 액정표시소자의 화소간섭 보상회로설계 (Design of Crosstalk Compensation Circuit in TFT-LCDs)

  • 정윤철;박종철;김이섭
    • 전자공학회논문지B
    • /
    • 제32B권11호
    • /
    • pp.1374-1382
    • /
    • 1995
  • In TFT-LCDs, as the display size area becomes larger, and the resolution higher, we have to consider the image degradation effects due to the incorporation of the TFT-LCD parameters such as the data-line resistance, the common electrode resistance, the data-line to common parasitic capacitance, and the output characteristics of driver ICs. One of the degradation effects is crosstalk resulting from the coupling between the source bus-line and common electrode. Since a source signal which represents a large number of display data is supposed to vary frequently, the common signal level is affected through the coupling effect, resulting in the degradation of nearby pixel drive signals. Therefore, we proposed a method to compensate for this source-common electrode coupling effect, we also designed and experimented the feasibility of our crosstalk compensation circuit in the actual TFT-LCD. We saw that the newly designed compensation circuit greatly reduced the crosstalk in display pattern image.

  • PDF

3상 오프라인 무정전 전원 시스템의 돌입전류 제거 (Inrush Current Elimination for a Three-Phase Off-Line UPS System)

  • ;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.944-945
    • /
    • 2015
  • Many sensitive loads always rely on UPS systems to maintain continuous power during abnormal utility power conditions. As any disturbance occurs at the utility side, an off-line UPS system takes over the load within a quarter cycle to avoid a blackout. However, the starting of the inverter can root the momentous inrush current for the transformer installed before the load, due to its magnetic saturation. The consequences of this current can be a reduction of line voltage and tripping of protective devices of the UPS system. Furthermore, it can also damage the transformer and decrease its lifetime by increasing the mechanical stresses on its windings. To prevent the inrush current, and to avoid its disruptive effects, this paper proposes an off-line UPS system that eliminates the inrush current phenomenon while powering the transformer coupled loads, using a current regulated voltage source inverter (CRVSI) instead of a typical voltage source inverter (VSI). Simulations have been performed to validate the operation of proposed off-line UPS system.

  • PDF

충주지역의 대기환경용량 추정에 관한 연구 (A Study on the Atmospheric Environmental Capacity in Chungju Area)

  • 박상찬;연익준;조병렬;조중식;강병욱
    • 한국대기환경학회지
    • /
    • 제24권1호
    • /
    • pp.122-127
    • /
    • 2008
  • The purpose of this study is to calculate atmospheric environmental capacity for $PM_{10}$, $NO_2$ and $SO_2$ using a rollback model in Chungju. From the results of this study, the source contributions for $PM_{10}$ and $NO_2$ was the following order: line source > area source > point source. However, the source contributions for $SO_2$ was the following: point source > area source > line source. While the atmospheric environmental capacity of $NO_2$ and $SO_2$ was enough to meet the regional air quality target, $PM_{10}$ emission needs to be reduced by 5%.

전력선 유도 환경에서의 지면 반사계 영향 분석 (Earth Reflection Effect Analysis in the Environment of Line Source Induction)

  • 이상무
    • 전자공학회논문지
    • /
    • 제50권4호
    • /
    • pp.26-32
    • /
    • 2013
  • 전력선에 의한 전자유도 환경에서 가장 보편적 영향 요인이라 할 수 있는 대지의 유도전압 감쇠 효과에 대하여 분석하였다. 전력선은 원통좌표계의 라인소스로 표현되고 계의 분석은 베셀함수와 웨이브 트랜스포메이션에 의한 이의 변형 적용을 통하여 해석된다. 라인소스로부터 방사된 전자계는 지표면에서 반사되어 관측점의 피유도원 매체에 합성되는데 이것의 영향을 알기 위하여 본 논문에서는 베셀함수에 의한 지면 반사계수를 직접 구하여 산출하도록 적용하였다. 본 논문에서 설계된 통상의 유도 환경의 배치 관계에 따르면 지면반사에 의한 원천 유도원 전압과의 합성 효율은 유도전압을 감쇠시키는 차폐효과로서 60~70%정도의 범위를 나타내었다.