• Title/Summary/Keyword: line impedance

Search Result 936, Processing Time 0.024 seconds

The Design of Lumped Constant Circuit for the Simulation of A Real 22.9 kV-y Distribution Line (22.9 kV-y 실긍장 배전선로 모의를 위한 집중정수회로의 설계)

  • Yun, Chul-Ho;Jeong, Yeong-Ho;Han, Yong-Huei
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1186-1188
    • /
    • 1999
  • When we perform the test related to the power distribution system such as artificial fault test, protective coordination test, distribution automation test in short length test line, Lumped Constant Circuit, a kind of variable impedance, should be attached to the test line in order to make it equivalent to a real line in length electrically. In this paper we designed the positive sequence and zero sequence Lumped Constant Circuit with optimized inductor and resister for the modification of long, 16km, distribution line, when they are attached to the short, 4km, distribution test line.

  • PDF

The study of emissive electromagnetic interference DMT PLC(Power Line Communication) (DMT 방식 전력선 통신의 전자파 장애에 관한 연구)

  • Choi, Jong-Pil;Shin, Chull-Chai
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.604-608
    • /
    • 2003
  • In this paper, we studied the radiated electric field of power-line with DMT signal source in the frequency range of $1.7{\sim}30 MHz$. First, we made the midium voltage power-line communication model for PLC and calculated the current through the power-line using the impedance of the power-line model. Second, we calculated the radiated electric field in power range $-50{\sim}-30 dBm$ using the calculated current. Consequently, the calculated emissive electromagnetic field from the DMT signal is similar to the measured result. So this study is applicable to the standard regulation of electromagnetic interference for PLC.

  • PDF

A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC) (전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구)

  • 신관우;김용태;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

Compact Open-stub Band-pass Filter with Narrow Bandwidth Using Impedance Mismatching of the Transmission- line (전송선로의 임피던스 부정합을 이용한 협대역 개방형 소형 스터브 대역통과 여파기)

  • Yoon, Ki-Cheol;Oh, Seung-Yeon;Oh, Kyoung-Min;Lee, Hyun-Wook;Hong, Tae-Ui;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.38-47
    • /
    • 2008
  • In this paper, the narrow band-pass filter with compact-size using the ${\lambda}g/2$ open stubs is proposed. The filter size is reduced by realization of transmission line at second harmonics and at the same time the power can be transferred to the output by using the fundamental wave generated in the resonator and the transmission line in which the impedance mismatch technique is adopted. Thus, the proposed filter can be reduced to half-length of horizontal transmission line than the conventional one. The experimental results show that insertion loss is 1.58 dB and return loss is 9.86 dB, and the fractional bandwidth is 10 % at the center frequency of 5.8 GHz. The filter size is $10.34{\times}18.56\;mm2$.

  • PDF

Design of Wideband Small Antenna for UWB Communication (UWB 통신용 광대역 소형 안테나 설계)

  • Ko Ji-Whan;Shin In-Ho;Lee Young-Soon;Cho Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1086-1098
    • /
    • 2005
  • Two types of small wideband antennas are proposed for UWB application. One type is small biconical structure fed by coaxial probe, which is easy to be installed on the circuit board. The other type is of planar bow-tie type fed by coplanar transmission line. Generally, the bandwidth of the latter type is significantly narrower than that of the former type. It is shown, however that the bandwidth of the latter type can be made to be comparable to that of the former, if some series inductive component is introduced in the center conductor line in the CPW transmission line by replacing some part of center line with narrower line of higher characteristic impedance. The series inductance component play an important role of neutralizing the capacitive component of the small bow-tie antenna, thereby making broadband impedance matching possible. The small planar bow-tie antenna was fabricated and experimented. The experimental results for return loss are observed to be in good agreement with simulated results. The radiation pattern is also investigated experimentally.

Improvement of Attenuation Characteristics for Multiple Coupled Line Structure on the Specific Lossy Media (특정 손실 매질위의 다중 결합선로에 대한 손실특성 개선)

  • Kim, Yoon-Suk;Kim, Min-Su
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.12
    • /
    • pp.35-41
    • /
    • 2011
  • In this paper, an analysis for a new substrate shielding symmetric coupled MIS structure consisting of grounded crossbar at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain(FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded crossbar lines over time-domain signal has been examined. Parameters of symmetric coupled MIS transmission line with various gaps between crossbars for even- and odd-mode are investigated as the functions of frequency, and the extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor for the new MIS crossbar embedded structure are also presented. It is shown that the quality factor of the symmetric coupled transmission line can be improved without significant change in the characteristic impedance and effective dielectric constant.

The Study on Relation of Obesity and Low Back Pain Based on Body Composition using Segmental Bioelectrical Impedance Analysis and Radiological Parameter (체성분 분석 변수와 X-선 소견을 근거로 한 비만과 요통의 관계 연구)

  • Park, Ji-Hyun;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.289-302
    • /
    • 2009
  • Objectives : This study was performed in order to investigate the relation of body composition analysis and radiological parameter(lumbosacral angle, lumbar lordortic angle, lumbar gravity line). Methods : This study was carried out with the data from comprehensive medical testing. 75 subject aged 20-59 performed the segmental bioelectrical impedance analysis, questionnaire. And lumbosacral angle, lumbar lordortic angle and lumbar gravity line were measured in the standing position x-ray. Then we analyzed the data. Results : Low back pain(LBP) prevalence in high obesity index(Body Mass Index(BMI), Percentage of Body Fat(PBF), Waist Hip Ratio(WHR)) group was higher than LBP prevalence in normal obesity index group(p<0.01). In LBP group, lumbosacral angle, lumbar lordortic angle were significantly lager than Non-LBP group(p<0.001). And 75% of LBP group indicated abnormal lumbar gravity line ratio(0.67 < Normal lumbar gravity line ratio <1.00). When it comes to analyze relation between obesity index and radiological parameter, no-significant change was seen. Conclusions : This study carried as following research after the study on relation of obesity, LBP and trunk muscle strength. Results from this investigation showed positive correlation between obesity and LBP prevalence. But obesity index didn't indicate significant correlation with structural changes of lumbar vertebrae. When considering prior research, trunk muscle strength changes were more related to LBP prevelence in obese people. This results are expected to explain causes of LBP in obese group.

Coplanar Waveguide Bandpass Filter Using the Folded-line Stepped- Impedance Restorator (접힌 스텝 임피던스 공진기를 이용한 CPW 대역 통과 여파기)

  • 이진택;이창언;신철재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.620-625
    • /
    • 2003
  • The coplanar waveguide bandpass filter using folded-line stepped-impedance resonators(SIRs) is proposed. The folded-line SIR has about λ/8 length using the short-circuited end on coplanar waveguide. It make that the bandpass filter has the half size in comparison with general λ/4 SIR filter. In this paper, we derive the equivalent circuit and design the bandpass filter by using that. We design and fabricate the bandpass filter which has 5 GHz center frequency and 3 % fractional bandwidth. The measurement results fur 4-pole folded SIR bandpass filter agreed well with full-wave simulation and equivalent circuit results. The fabricated bandpass filter has a good spurious characteristic, which the harmonic frequency appeared at 2.5f$\_$0/). The proposed folded-line SIR bandpass filter are applicable for MMIC and High-Tc superconducting filters. bandwidth.

Analysis of a transmission line on Si-based lossy structure using Finite-Difference Time-Domain(FDTD) method (손실있는 실리콘 반도체위에 제작된 전송선로의 유한차분법을 이용한 해석)

  • 김윤석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9B
    • /
    • pp.1527-1533
    • /
    • 2000
  • Basically, a general characterization procedure based on the extraction of the characteristic impedance and propagation constant for analyzing a single MIS(Metal-Insulator-Semiconductor) transmission line is used. In this paper, an analysis for a new substrate shielding MIS structure consisting of grounded cross-bars at the interface between Si and SiO2 layer using the Finite-Difference Time-Domain (FDTD) method is presented. In order to reduce the substrate effects on the transmission line characteristics, a shielding structure consisting of grounded cross bar lines over time-domain signal has been examined. The extracted distributed frequency-dependent transmission line parameters and corresponding equivalent circuit parameters as well as quality factor have been examined as functions of cross-bar spacing and frequency. It is shown that the quality factor of the transmission line can be improved without significant change in the characteristic impedance and effectve dielectric constant.

  • PDF

Optimized Design Technique of a Differential Pair Having 2 Drop Configuration through Impedance Analysis (2 Drop 구조를 가지는 Differential Pair의 Impedance 해석 및 설계 방안)

  • Bae, Min-Ji;Kim, Yoon-Jung;Choi, Ung;Yang, Kook-Bo;Kim, Young-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.193-199
    • /
    • 2009
  • In this paper, impedance analysis of a differential pall having 2 drop configuration is performed using the reflection theory and verified by circuit simulator (Ansoft designer). Through the impedance analysis, it was possible to understand the signal transmission at a differential pall, and an optimized 2 drop design technique of a differential pair could be developed. When compared with the conventional design, the proposed design shows a good signal integrity and has much less design restrictions.