• 제목/요약/키워드: line contact

검색결과 841건 처리시간 0.03초

발 뒤축 내·외측 경사진 안창이 족부압력에 미치는 영향 (Effects of Rear-Foot Wedged Insoles on the Foot Pressure in Walking)

  • 유태범;채병기;임완수;최화순;정민근
    • 대한산업공학회지
    • /
    • 제34권1호
    • /
    • pp.90-97
    • /
    • 2008
  • Wedged insoles are frequently used to reduce the pains caused by the knee arthritis or the foot overuse syndrome. The present study analyzed the effect of wedged rear-foot insoles on the foot pressure in walking. Three medially wedged insoles with three angles (5, 8 and 15") and three laterally wedged insoles with the same angles were made, and a flat insole were prepared. Ten healthy males in twenties walked in a specified line with each insole. Center of pressure (COP), relative vertical force and maximum force on anatomical areas were analyzed from the measured foot pressure data. At heel contact, medially wedged insoles significantly increased the pressure of the medial foot side (COP moved medially by 2-5 mm and maximum pressure of 1st metatarsal head increased by 110-120% relative to the flat insole), In contrast, laterally wedged insoles significantly increased the lateral side pressure (COP moved laterally by 1-5 mm and the ratio of $2^{nd}$ metatarsal head pressure to $1^{st}$ metatarsal head increased by 0.5-2.0 relative to the flat insole). At toe off, both wedged insoles significantly increased the pressure of the medial foot side (COP moved medially by 0.5-10 mm and the ratio of $1^{st}$ metatarsal head pressure to $5^{th}$ metatarsal head increased by 2.0 relative to the flat insole). Especially, the laterally wedged insoles significantly increased the relative vertical force (6-12%) of the rear-foot more than the flat insole.

양궁화살에 의한 두부 관통상 1례 - 증례보고 - (A Case of Penetrating Head Injury by a Western-Style Arrow - A Case Report -)

  • 조태현;송준혁;김명현;박향권;김성학;신규만;박동빈
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권11호
    • /
    • pp.1538-1541
    • /
    • 2000
  • Apenetrating head injury by an arrow is extremely rare being only two cases reported in the literature. We report a case of 12-year-old boy who presented with an arrow lodged at the posterior fossa through nasal nostril. He was slightly drowsy, but neurologically intact except a sixth nerve palsy in the left eye. Brain CT showed no intracerebral hemorrhage. The arrow was entered through the right nostril and the tip was stucked in the left cere-bello-pontine angle through the sphenoid sinus. We removed the arrow without craniotomy since the tip was verified smooth and no cerebral arteries were in contact with the arrow. The patient recovered well without any significant complications. The sixth nerve palsy resolved completely after six months. The verification of the shape of the offending material, a retrograde removal of the arrow in the direction of its line of trajectory, and an identification of adjacent cerebral arteries seem to be important in the management of this type of injury.

  • PDF

분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석 (Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board)

  • 문현욱;김동우;길형준;김동욱;이기연;김향곤
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.100-106
    • /
    • 2009
  • 본 논문에서는 전기설비의 전기적 접속부 또는 전기배선 등에서 발생하는 이상발열을 감지하는 방법에 대해 알아보고, 분전함에서의 발열상태를 실시간으로 모니터링하는 전력설비 진단시스템에 사용되고 있는 광온도센서에 대하여 동작특성을 실험, 분석하였다. 광온도센서의 동작특성 실험을 위한 열원으로는 Black Body와 Hot Plate를 사용하였으며 각각에서의 열원의 온도변화에 따른 광온도센서 출력전압값을 측정, 분석하였다. 그리고 분전함내 차단기 단자에서의 체결불량으로 인한 이상발열 감지 실험을 기존의 발열 감지방법인 열전대와 적외선 열화상장치를 이용하여 실시하였고, 광온도센서를 이용해 실시하여 결과를 비교 분석하였다. 실험결과, 광온도센서의 이상발열 감지능력이 유사함을 확인할 수 있었다. 이러한 분석 결과는 향후 RFID형 광온도센서를 이용한 전력설비 진단시스템의 현장 적용에 있어 기본 자료가 될 것으로 기대된다.

Three-dimensional shape measurement using grating patterns form an optical spatial modulator

  • Tsujioka, Katsumi;Ito, Hiroshi;Furuhashi, Hideo;Higa, Shuntaro;Hayashi, Niichi;Yamada, Jun;Hatano, Kazuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.561-565
    • /
    • 1994
  • An automatic measuring system of three dimensional shape by a projection method with grating pattern from in optical spatial modulator has been developed. The characteristics of the system were studied. This system is composed of a projector, an optical spatial modulator, a CCD camera, and computer. A liquid crystal is used as the optical spatial modulator. The grating patterns that ire projected on the surface of the object are controlled by the computer connected with the optical spatial modulator. The projector patterns are measured by the CCD camera. The data are transferred to the computer. After a transformation into line data, the data are analyzed to obtain the coordinate of the surface of the object. This system has advantages as follows. (1) It is possible to capture the surface topography without any contact. (2) The time required for the measurements is shorter than the light-section method. (3) An optical spatial modulator using a liquid crystal is possible to control the grating patterns accurately by a computer. Surfaces of a plate and a cylinder were measured. The threshold level had an influence on the measurement. It was shown that this system has adequae accuracy in the measurements.

  • PDF

레이저 발생 초음파와 공기 정합 수신 탐촉자를 이용한 복합재료 적층판의 내부 박리 결함 평가 (Evaluation of Internal Defect of Composite Laminates Using A Novel Hybrid Laser Generation/Air-Coupled Detection Ultrasonic System)

  • 이준현;이승준;변준형
    • 비파괴검사학회지
    • /
    • 제28권1호
    • /
    • pp.46-53
    • /
    • 2008
  • 복합재료의 내부 결함 평가를 위해 일반적으로 적용되어온 초음파 C-스캔 기법은 섬유자동 배열을 통한 정밀 성형 공정에 적용하기에는 많은 어려움이 있다. 따라서 본 연구는 복합재료의 정밀 성형 공정 중에 발생되는 각종 내부 결함들을 비파괴적, 비접촉으로 평가하기 위한 새로운 하이브리드 초음파 평가 기법을 확립하는데 목적이 있다. 이를 위하여 본 연구에서는 초음파 산란 반사(scattering reflection) 방식을 토대로 한 새로운 이중 피치-캐치(dual pitch-catch) 기법을 확립하여 기존의 결함평가를 위해 시험편의 스캔에 소요되는 시간을 줄이면서 우수한 결함 영상을 얻을 수 있는 새로운 하이브리드 기법을 개발하였다. 즉 두 가지 종류의 열경화성 및 열가소성 복합재료(carbon/epoxy, carbon/PPS) 적층판의 내부 박리(delamination) 결함의 영상화를 위하여 레이저를 이용한 유도 초음파의 발생 및 이중 피치-캐치(pitch-catch)방식을 토대로 한 비접촉식 공기 정합 트랜스듀서(air-coupled transducer)를 이용하여 결함 영상을 얻기 위한 핵심 알고리즘을 확립하였다.

Biomechanical Analysis at the Start of Bobsleigh Run in Preparation for the 2018 Pyeongchang Winter Olympics

  • Park, Seungbum;Lee, Kyungdeuk;Kim, Daewoong;Yoo, Junghyeon;Jung, Jaemin;Park, Kyunghwan
    • 한국운동역학회지
    • /
    • 제27권4호
    • /
    • pp.239-245
    • /
    • 2017
  • Objective: The bobsleigh shoes used in the start section are one of the most important equipment for improving the competition. Despite the importance of the start section, there are no shoes that are specific for bobsleigh athletes in Korea and Korean athletes have to wear sprint spike shoes and practice the start instead of wearing bobsleigh shoes. The objective of the present study was to provide data for improving the performance of Korean bobsleigh athletes by investigating the differences in their split time, plantar pressure, and forefoot bending angle based on skill levels at the start of a run under the same conditions as training conditions. Method: Six Korean bobsleigh athletes were divided into two groups, superior (n=3) and non-superior (n=3). A digital speedometer measured the split time at the start; the Pedar-X system (Novel, Germany) measured plantar pressure. Plantar pressures and split times were measured as the athletes pushed a bobsleigh and sprinted at full speed from the start line to the 10-m mark on the bobsleigh track. An ultra-high-speed camera was used to measure the forefoot bending angle during the start phase. Results: Significant between-group differences were found in split times (p<.000; superior = 2.38 s, non-superior = 2.52 s). The superior group had a larger rearfoot (p<.05) contact area, maximum rearfoot force (p<.01), and a larger change in angles 3 and 4 (p<.05). Conclusion: At the start of a bobsleigh run, proper use of the rearfoot for achieving effective driving force and increasing frictional resistance through a wider frictional force can shorten start time.

간호사의 AIDS에 대한 지식과 태도 (Nurses' Knowledge about and Attitudes toward AIDS and Patients with AIDS)

  • 손정태
    • 기본간호학회지
    • /
    • 제6권3호
    • /
    • pp.544-558
    • /
    • 1999
  • With the increasing incidence of AIDS, it is probably inevitable that nurses working in hospital and community settings will come in contact with patients with AIDS. Nurses, more than any other health care profession, are on the front line of AIDS patient care. The purposes of this descriptive study were to gather information about registered nurses' knowledge and attitude regarding AIDS. and to provide a basis for the development of continuining education programs for the nurse. Data was gathered in 1988 using self-administered questionnaires given to a convinience sample of two hundred seventy registered nurses from two university hospitals, school nurses and postgraduate students of nursing. Data was analyzed with SAS. The results were as follows. Above 90% of the nurse knew well about definition of AIDS and routes of transmission but nurses relatively lacked knowledge about transmission of HIV in breast milk(69.3%). Less than half knew that drug abuser(44.1%) and sexual partner with IV drug abuser(39.6%) are at high risk for contracting AIDS. Above 70% of the nurse showed reluctance to provide care for surgery. delivery of child birth and hemodialysis of patients with AIDS. The results showed that, given a choice. 41.7% of the nurse would refuse to care for AIDS patients and 48.3% claimed that they should have a right refuse to care for AIDS patients. Reluctance of nursing patient with AIDS appeared to be principally associated with general fear of becoming infected with HIV. 41.8% exhibited a sympathetic attitude toward individual AIDS patient. The study findings suggest that it is necessary to examine the correlations between knowledge and attitude and to develop continuing education programs that alleviate the fear of contagion of the nurse.

  • PDF

LOADED IMPLANT와 UNLOADED IMPLANT의 조직학적 비교 연구 (A HISTOLOGIC COMPARATIVE STUDY OF LOADED AND UNLOADED TITANIUM IMPLANTS)

  • 김영수;고재승;황성명
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.1-16
    • /
    • 1991
  • In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.

  • PDF

Experimental investigation of force-distribution in high-strength bolts in extended end-plate connections

  • Abdalla, K.M.;Abu-Farsakh, G.A.R.;Barakat, S.A.
    • Steel and Composite Structures
    • /
    • 제7권2호
    • /
    • pp.87-103
    • /
    • 2007
  • This paper presents some of the results from an experimental research project on the behavior of extended end-plate connections subjected to moment conducted at the Structural Laboratory of Jordan University of Science and Technology. Since the connection behavior affects the structural frame response, it must be included in the global analysis and design. In this study, the behavior of six full-scale stiffened and unstiffened cantilever connections of HEA- and IPE-sections has been investigated. Eight high strength bolts were used to connect the extended end-plate to the column flange in each case. Strain gauges were installed inside each of the top six bolts in order to obtain experimentally the actual tension force induced within each bolt. Then the connection behavior is characterized by the tension force in the bolt, extended end-plate behavior, moment-rotation relation, and beam and column strains. Some or all of these characteristics are used by many Standards; therefore, it is essential to predict the global behavior of column-beam connections by their geometrical and mechanical properties. The experimental test results are compared with two theoretical (equal distribution and linear distribution) approaches in order to assess the capabilities and accuracy of the theoretical models. A simple model of the joint is established and the essential parameters to predict its strength and deformational behavior are determined. The equal distribution method reasonably determined the tension forces in the upper two bolts while the linear distribution method underestimated them. The deformation behavior of the tested connections was characterized by separation of the column-flange from the extended end-plate almost down to the level of the upper two bolts of the lower group and below this level the two parts remained in full contact. The neutral axis of the deformed joint is reasonably assumed to pass very close to the line joining the upper two bolts of the lower group. Smooth monotonic moment-rotation relations for the all tested frames were observed.

Endovascular Approach in Patients with Acute Complete Occlusion Due to Middle Cerebral Artery Dissection

  • Park, Kang-Hoon;Kwak, Hyo Sung;Park, Jung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권6호
    • /
    • pp.717-722
    • /
    • 2020
  • Objective : Dissection of the middle cerebral artery (MCA) is less common than dissection of vessels in the vertebrobasilar system or carotid artery. Acute complete occlusion related to MCA dissection is extremely rare. We report an endovascular approach in patients with acute complete occlusion due to MCA dissection. Methods : We reviewed retrospectively the endovascular procedure and clinical results for acute-stroke patients who underwent recanalization from October 2014 through December 2018. Initial imaging findings and the endovascular procedure were analyzed for patients with acute complete occlusion due to MCA dissection. Results : We undertook first-line aspiration thrombectomy using a Penumbra catheter in 294 patients with acute occlusion of the M1 segment. Of these patients, seven were confirmed to have acute complete occlusion due to MCA dissection. All patients had angiographic findings of an intimal flap at the proximal occlusion site of the MCA. One patient complained of severe headache during microcatheter passage through the occluded lesion and died due to massive bleeding caused by rupture of the false lumen. The remaining patients underwent initial contact aspiration thrombectomy without microcatheter passage. After aspiration thrombectomy, six patients had delayed flow through the MCA. One patient underwent stenting of the MCA because of progressive symptoms. Conclusion : An intimal flap at the proximal portion of an occluded MCA can suggest the possibility of MCA dissection. Contrast aspiration thrombectomy without microcatheter passage can reduce the risk of false lumen rupture in cases of MCA dissection.