• Title/Summary/Keyword: line center

Search Result 4,344, Processing Time 0.032 seconds

Characteristic Analysis of Line-start Permanent Magnet Synchronous Motor considering Skew Effect (Skew를 고려한 유도기동형 영구자석 동기전동기의 특성 해석)

  • Oh, Young-Jin;Lee, In-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.12-14
    • /
    • 2005
  • This study investigates the characteristic analysis of Line-start Permanent Magnet Synchronous Motor considering skew effect. The effects of the skew on machine characteristic are analyzed by using direct co-simulation of Matlab Simulink and Flux2D. Validity of analysis method is confirmed by the analysis result of Non-skew Model.

  • PDF

Ultra Wideband Bandpsss Filter Design using the CRLH Transmission Line (CRLH 전송선로를 이용한 초광대역 대역통과 필터의 설계 및 구현)

  • Kim, Gi-Rae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2233-2238
    • /
    • 2013
  • A novel design method of ultra wideband based on the composite right-/left handed (CRLH) transmission line is presented in this paper. Defected ground structure and microstrip interdigital coupler are used to implement the CRLH transmission line. The proposed CRLH transmission line in this paper have composite characteristics of low pass filter and high pass filter, also it has good advantages of low insertion loss and ultra wide passband characteristics. The structure with different cell number are studied, and the UWB filter using 3-cell CRLH transmission line is fabricated and measured, which shows a good agreement between simulated and measured results. It has center frequency of 5 GHz, fractional bandwidth of 105 %, and insertion loss of 0.7 dB at center frequency.

Transglutaminase 2 mRNA Expression in Salivary Gland Tumor Cell Line

  • Chun, Yoon Kwon;Lee, Chong Heon
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.22-26
    • /
    • 2013
  • Purpose: Transglutaminase 2 (TGase 2) is expressed by tumor necrosis factor-${\alpha}$ in various carcinoma. The role of TGase 2 expression in salivary gland tumors is not clear yet. Established slaivary gland tumor (SGT)cell line has been used to study the pathogenesis of salivary gland adenocarcinoma on a cellular level in vitro. The pupose of this study were to examine mRNA expression of TGase 2 in SGT cell line compared to other tumor cell lines, and to apply these results to the pathogenesis of salivary gland tumor. Materials and Methods: After SGT, SCC-15, HN 4, and HeLa tumor cell lines were cultured under preconfl uency, and 3 days after postconfl uency, the cells were harvested for total RNA extraction and cDNA preparation. Result: Reverse transcription polymerase chain reaction for semiquantitative mRNA analysis was done. TGase 2 mRNA expression was not induced by confl uency in all the cell lines. TGase 2 mRNA expression was variable but markedly enhanced in SGT cell line. Conclusion: mRNA expression of TGase 2 should play an important role in the pathogenesis of SGT cell line originated from ductal cell.

Erosion Control Line (ECL) Establishment Using Coastal Erosion Width Prediction Model by High Wave Height (고파랑 해안 침식폭 예측모델을 이용한 침식한계선(ECL) 설정)

  • Park, Seung-Min;Park, Seol-Hwa;Lee, Jung-Lyul;Kim, Tae-Kon
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.526-534
    • /
    • 2019
  • The average coastline and the erosion control line introduced as the management coastline, and the average shoreline (MSL) was established from the observed coastline. Also, the median grain size and the wave height of 30-years return period were applied. The erosion control line (ECL) was established through the model, HaeSaBeeN. These two lines set the coastline for evaluation. Based on the observed monitoring data along the coastline, the 1-day variation according to the normal distribution was used to estimate the regional variation, and the width of the erosion was calculated by applying the median grain size (D50) and the wave height of 30-years return period through the high-wave coastal erosion width model, i.e., HaeSaBeeN.

Active noise control with the active muffler in automotive exhaust system (액티브 머플러를 이용한 자동차 배기계의 능동소음제어)

  • Kim, Heung-Seob;Hong, Jin-Seok;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1837-1843
    • /
    • 1997
  • This study experimentally demonstrates the use of active muffler attached to the automotive exhaust system to reduce exhaust noise. For improving the signal to noise ratio in the process of estimation of secondary path transfer functions, the on-line algorithm that conventional inverse modeling is combined with adaptive line enhancer is used as the control algorithm. Active muffler is designed that the primary noise and the control sound are propagated as a plane wave in the outlet. Therefore, the error microphone could be placed out of the tail pipe center of a high temperature and the radiation noise to the outside could be reduced in the whole area around the outlet. The control experiment for reducing exhaust noise with active muffler is implemented during run-up at no load. From the experimental results presented, compared with the conventional off-line method, the proposed on-line method is capable to acquire a reduction of exhaust noise above 5 dB in overall sound power level.

Effect of Source Line Location on Lift-off Acoustic Loads of a Launch Vehicle (음원 분포선 위치가 발사체 이륙 음향하중에 미치는 영향)

  • Choi, Sang-Hyeon;Ih, Jeong-Guon;Lee, Ik-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.539-545
    • /
    • 2015
  • Intense acoustic load is generated when a launch vehicle lifts off, causing the damaging vibrations at the launch vehicle or satellite within the fairing. This paper is concerned with the prediction of lift-off acoustic loads for a launch vehicle. As a test example, the lift-off acoustic load on the Korean launch vehicle, NARO, is predicted by the existing calculation tool, the modified Eldred's second method. Although the acoustic sources, assumed as point sources, are to be located along the center line of the exhaust plume when using the Eldred's prediction method, the exact location of the deflected center line of exhaust gas flow is not usually known. To search for the most appropriate source positions, six models of source line distribution are suggested and the acoustic load prediction results from these models are compared with the actual measurements. It is found that the predicted sound pressure spectrum of the Naro is the most similar to the measured data when the centerline of the turbulent kinetic energy contour is used as the source line.

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines (송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용)

  • Ju, Yun-Ro;Yang, Gwang-Ho;Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.

Design and Control Method for Sub-module DC Voltage Ripple of HVDC-MMC

  • Gwon, Jin-Su;Park, Jung-Woo;Kang, Dea-Wook;Kim, Sungshin
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.921-930
    • /
    • 2016
  • This paper proposes a design and control method for a high-voltage direction current modular multilevel converter (HVDC-MMC) considering the capacitor voltage ripple of the submodule (SM). The capacitor voltage ripple consists of the line frequency and double-line-frequency components. The double line- frequency component does not fluctuate according to the active power, whereas the line-frequency component is highly influenced by the grid-side voltage and current. If the grid voltage drops, a conventional converter increases the current to maintain the active power. A grid voltage drops, current increment, or both occur with a capacitor voltage ripple higher than the limit value. In order to reliably control an MMC within a limit value, the SM capacitor should be designed on the basis of the capacitor voltage ripple. In this paper, the capacitor voltage ripple according to the grid voltage and current are analyzed, and the proposed control method includes a current limitation method considering the capacitor voltage ripple. The proposed design and control method are verified through simulation using PSCAD/EMTDC.