• 제목/요약/키워드: line center

검색결과 4,334건 처리시간 0.029초

파이프 원주방향 용접부의 잔류응력분포 특성에 관한 실험적 연구 (An Experimental Study on the Residual Stress Distribution at Circumferential Welds in Pipes)

  • 남궁재관;홍재학
    • 한국정밀공학회지
    • /
    • 제8권1호
    • /
    • pp.41-49
    • /
    • 1991
  • A knowledge of the resdual stress distribution at circumferential weldments can normally increase the accuracy of a fracture assessment in pipe line. In this paper, we present the measurements about the residual stress distributions at three kinds of circumferential butt welded pipes using the holl drilling strain gage method. By this experiment, we have obtined the following characteristics. At the inner surface of the pipe region near the center line of welding is under high tensile residual stress. However, as the distance from the center line of welding increases, the tensile component decreases and finally becomes compressive residual stress at region far away from the center line of welding. The longitudinal residual stress at the outer surface is compressive regardless of the diameter of pipe and the circumferential stress is changed from compressive to tensile as pipe diameter increases. The results also demonstrate that the residual stress is mainly caused by self-restraint bending force in the pipe welding.

  • PDF

엉덩이가 큰 여성의 바지 패턴 연구 -허리둘레와 엉덩이둘레 차이 27cm 이상을 중심으로- (Study of Pants Pattern Design for Women with Large Hips -Focusing on the Difference of 27cm or More Between Waist and Hip Circumference-)

  • 차수정
    • 한국의류학회지
    • /
    • 제48권4호
    • /
    • pp.756-773
    • /
    • 2024
  • This study proposes a prototype design method for pants suited to adult women with a difference of 27cm or more between the circumference of their waist and hip. The first pattern was modified around the hem, in the number of darts at the waist and in the slope of the front center. The second pattern was modified in the position of the waist darts and the length of the front and back darts. The third pattern showed side-line wrinkling, so the slope of the side-line and the number of darts were adjusted. Pants patterns for women with large hips can be calculated by inserting the difference between hip and waist circumference in the settings for the center front angle, center back angle, front side line angle, back side line angle, dart length, etc. This enables designers to draft pants patterns suited to the body shape of women with a difference in hip and waist circumference of 27cm or more.

On-Line Real Time System의 개념 2

  • 박영문
    • 전기의세계
    • /
    • 제23권2호
    • /
    • pp.23-27
    • /
    • 1974
  • On-line real time system은 보통 중앙장치(computing center), 단말장치(remote terminal) 및 통신회선(communication link)의 세부분시스템(subsystem)으로 구성되어 있는데, 이들 각각에 대한 구성요소와 그 기능에 대하여 약술하려고 한다.

  • PDF

고에너지 물질 시뮬란트의 분산도의 In-Line 모니터링 (In-Line Monitoring the Dispersion of Highly Energetic Material Simulant)

  • 이상묵;홍인권;안영준;이재욱
    • 폴리머
    • /
    • 제38권3호
    • /
    • pp.272-277
    • /
    • 2014
  • 고온용 초음파 측정 시스템을 장착한 이축압출기를 이용하여 고에너지 물질 시뮬란트의 분산도를 실시간으로 모니터링하는 연구를 하였다. 결합제 수지 및 충전제로 ethylene vinyl acetate(EVA)와 Dechlorane plus 25를 각각 사용하여 고에너지 물질 시뮬란트 현탁계를 구성하였다. 충전 부피분율이 증가함에 따라 현탁계의 초음파 속도는 전혀 변화를 보이지 않았으나 초음파 감쇠는 선형적으로 감소하였는 바 고르게 분산된 현탁계를 대상으로 초음파 감쇠를 측정하면 충전함량을 추정할 수 있음을 확인하였다. 또한 60 v% 이상으로 충전된 고농축 현탁계에서는 반복 압출실험을 수행한 결과 초음파 감쇠의 편차가 감소하여 직선값에 접근하는 경향을 보이는 바 분산도의 증가하는 것을 알 수 있었다. 따라서 on-line 및 in-line으로 측정된 초음파 감쇠와 off-line으로 SEM 및 Image Analyzer 그리고 열중량분석을 병행함으로써 분산도 및 충전 함량을 평가할 수 있을 것으로 사료된다.

두가지 두부 방사선 사진 중첩 방법의 비교 - Nasion-Sella line 중첩과 Anterior cranial base 중첩 (Comparision of two cephalometric superimposition methods - Nasion-sella line method and Anterior cranial base method)

  • 경승현;문윤식
    • 대한치과교정학회지
    • /
    • 제27권4호
    • /
    • pp.633-641
    • /
    • 1997
  • 성장 또는 치료로 인한 악안면골의 변화는 두부 방사선을 중첩 함으로써 판단할 수 있다. 중첩에 대한 평가는 중첩방법에 따라 변화되므로 좀더 정확한 중첩 방법을 선택하는 것은 치료 효과에 대한 분석이나 성장 변화에 대한 평가를 정확히하는 선결 요건이 될것이다. 3년 정도의 비교적 짧은 성장기간을 가진 11세 전후의 여자 환자 19명을 대상으로, 가장 널리쓰이는 중첩 방법인 Nasion-Sells line중첩과 Bjork가 주장하는 Anteirior cranial base (ACB)중첩을 비교하여 다음과 같은 결론을 얻었다. 1 Nasion-Sells line중첩과 ACB중첩은 중첩오차(registration error)의 크기가 거의 같아서 reliability에 있어서 큰차이가 없는 것으로 나타났다 2. 검사자간 차이(interobserver difference)에 있어서 Nasion-Sells line중첩은 7개의 측정 항목 모두에서 두 검사자간에 차이가 없었으나 ACB중첩은 7개의 측정 항목중 4개의 측정 항목에서 두 검사자간 유의성 있는 차이가 나타났다. 3. 중첩방법의 차이 (intermethod difference)에 있어서 Nasion-Sella line중첩으로 측정한 계 측치와 ACB 중첩으로 측정한 계측치가 유의성있게 차이가 나지 않았다.

  • PDF

지하상가 실내외 및 지하철의 온도와 습도에 따른 Formaldehyde 거동(II) (Behavior of Formaldehyde Concentration by Temperature and Humidity of Indoor and Outdoor in Underground Shopping Center and Subway(II))

  • 권우택
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.67-75
    • /
    • 1994
  • Formaldehyde has been in widespread industrial use since World War II . Numerous sources of formaldehyde are present in the indoor environment. Additionally, the current trend toward tighter, more energy efficient buildings with lower ventilation rates has led to increase concentrations of this and other pollutants generated indoors. In this paper, the field survey was carried out once a month from January to MarctL 1994 to measure indoor and outdoor formaldehyde concentration in several underground locations in Seoul. The results could be summarized as follows : 1. At Yang- jae underground shopping center, the mean formaldehyde concentration was 77.8ppb for indoor and 68.4ppb for outdoor. At Ban- po underground shopping center, it was 175.8ppb for indoor and 127.3ppb for outdoor. At Jam- shil underground shop ping center, it was 135.2ppd for indoor and 34.6ppb for outdoor. Indoor the No.2 sub way line, it was 105.6ppb. The formaldehyde concentration using Berge equation was as follows : At Yang- jae underground shopping center, the mean formaldehyde concentration was 85.99ppb for indoor and 72.75ppb for outdoor At Ban- po underground shopping center, it was 254. 17ppb for indoor and 138.14ppb for outdoor. At Jam- shil underground shopping center, it was 249.13ppb for indoor and 36.87ppb for outdoor. Indoor the No.2 subway line, it was 131.73ppb. 3, The result of correlation analysis indicated that the relationship between temperature and formaldehyde concentration is very high( $\gamma $= 0.831 ∼ 0.974). 4. Also, the relationship between humidity and formaldehyde concentration is variant ($\gamma $ = 0.246 ∼0.999). 5. The mean formaldehyde concentration indoor and outdoor Ban- po underground shop ping center and indoor Jam- shil underground shopping center and indoor the No.2 sub way line exceed the American Society of Heating, Refrigeration, Air- conditioning Engineers( ASHRAE) stflndard of 100ppb(120 $\mu $g/m$^{3}$).

  • PDF

Targeting Risk Factors for the Control of Central Line-Associated Bloodstream Infection in the Neonatal Intensive Care Unit: A Single Tertiary Center Experience

  • Jeong, Jiyoon;Kwun, Yoojin;Kim, Min-ju;Choi, Sang-Ho;Jung, Euiseok;Lee, Byong Sop;Kim, Ki-Soo;Kim, Ellen Ai-Rhan
    • Neonatal Medicine
    • /
    • 제28권3호
    • /
    • pp.116-123
    • /
    • 2021
  • Purpose: The aim of this study was to estimate the effect of targeting risk factors for the control of central line-associated bloodstream infection (CLABSI) among high-risk infants in a tertiary neonatal intensive care unit (NICU). Methods: Infants admitted to the NICU and diagnosed with CLABSI from January to December 2013 were eligible for inclusion to the study. The CLABSI group (n=47) was matched in a 1:2 ratio to the control group (n=94) based on gestational age, birth weight, and Score for Neonatal Acute Physiology-II. Risk factors for CLABSI were identified using the Cox proportional hazard model, and analysis of the effect of these risk factors targeting infection control was performed. Results: The risk factors associated with CLABSI were prolonged central line dwell days (adjusted hazard ratio [HR], 1.028; 95% confidence interval [CI], 1.011 to 1.045; P=0.001), use of a silicone catheter (adjusted HR, 5.895; 95% CI, 1.893 to 18.355; P=0.002), surgical treatment (adjusted HR, 3.793; 95% CI, 1.467 to 9.805; P=0.006), and less probiotic supplementation (adjusted HR, 0.254; 95% CI, 0.068 to 0.949; P=0.042). By targeting these risk factors with a quality improvement initiative, the mean CLABSI incidence rate per 1,000 catheter-days decreased from 6.6 to 3.1 (P=0.004). Conclusion: Targeting risk factors for infection control significantly reduced the rate of CLABSI among high-risk infants in the NICU.

저온동시소성용 감광성 은(Ag)페이스트의 광식각 특성 (Photolithographic Properties of Photosensitive Ag Paste for Low Temperature Cofiring)

  • Park, Seong-Dae;Kang, Na-Min;Lim, Jin-Kyu;Kim, Dong-Kook;Kang, Nam-Kee;Park, Jong-Chul
    • 한국세라믹학회지
    • /
    • 제41권4호
    • /
    • pp.313-322
    • /
    • 2004
  • 후막 광식각 기술은 스크린 인쇄 등의 일반적인 후막공정에 노광 및 현상 등의 리소그라피 공정을 접목시킨 새로운 기술이다. 본 연구에서는 후막 광식각 기술을 이용하여 미세라인을 형성할 수 있는 저온동시소성용 Ag 페이스트를 개발하였다. 페이스트를 구성하는 Ag분말과 폴리머, 모노머, 광개시제 등의 양을 조절하여 미세라인을 형성할 수 있는 최적 조성을 연구하였으며. 또한 노광량과 같은 공정변수가 미세라인 형성에 미치는 영향을 연구하였다. 실험결과 폴리머/모노머비, Ag 분말 중량비, 광개시제의 양 등이 미세라인의 해상도에 영향을 미치는 주요 인자임을 확인할 수 있었다. 개발된 감광성 Ag 페이스트를 저온동시소성용 그린 시트에 전면 인쇄한 후 건조, 노광, 현상, 적층, 소성 과정을 통하여, 소성 후 20$\mu\textrm{m}$ 이하의 선폭을 가지는 후막 미세라인을 형성할 수 있었다.

CCTV영상 내 교통량 분석을 위한 적응적 계수선 검출 방법 (Adaptive Counting Line Detection for Traffic Analysis in CCTV Videos)

  • 정현석;임석재;이용;박민우;이상환;김원준
    • 방송공학회논문지
    • /
    • 제25권1호
    • /
    • pp.48-57
    • /
    • 2020
  • 최근 영상 인식 기술의 급격한 발전으로 도로 교통 CCTV영상 내에서의 객체 분석 요구가 증대되고 있다. 본 논문에서는 도로 교통 CCTV영상 내의 교통량 분석을 위한 계수선(Counting Line)을 도로의 형태에 따라 적응적으로 검출할 수 있는 방법을 제안한다. 우선 도로 위의 차량을 검출하고 검출한 차량의 위치를 이차원 가우시안 형태의 함수로 모델링 한 후, 이를 연속된 프레임 상에서 누적하여 차량의 이동 경로를 표현하는 누적 가우시안 지도를 얻어낸다. 이렇게 얻어낸 누적 가우시안 지도에 군집화 및 선형 회귀를 적용하여 도로의 주방향을 구하고, 이 주방향을 이용하여 최종적으로 교통량 분석을 위한 계수선을 검출한다. 다양한 CCTV상황에서 제안하는 방법을 적용하였을 때 계수선을 효과적으로 검출할 수 있는 것을 실험적으로 확인하였다.