• Title/Summary/Keyword: limits of stability

Search Result 353, Processing Time 0.027 seconds

Changes of postural stability according to ankle fixation in healthy subjects

  • Jeong, Su-Hyeon;Mun, A-Young;Lee, Song-Eun;Kim, Min-Ju;Lee, Hui-Jin;Baek, Kook-Bin;Cho, Ki Hun
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • Objective: The purpose of this study was to examine the changes in postural stability according to ankle fixation in healthy university students. Design: Cross-sectional study. Methods: Thirty healthy subjects (15 males and 15 females, 20.13 years, 167.49 cm, 65.87 kg) were recruited on a voluntary basis. The BT4 system (HUR Laps Oy, Tampere, Finland) was used to measure the static (standing posture with eyes open and eyes closed) and dynamic (external perturbation and limits of stability (LOS) in the forward, backward, left, and right side) balance abilities. External perturbation was measured by the subject's postural sway velocity and area for 20 seconds after being impacted by a gym ball. Static and dynamic stabilities were measured with ankle joint fixation and non-fixation conditions. Ankle fixation was provided using Mueller tape on both ankle joints. Results: For static stability under the standing posture, there was no significant difference between standing with ankle joint fixation and non-fixation conditions. However, dynamic stability (external perturbation and LOS in the forward, backward, left, and right side) was significantly higher in the standing with the non-fixation condition compared to the standing with ankle joint fixation condition (p<0.05). Conclusions: Our results reveal that ankle joint fixation can influence dynamic stability during standing. Thus, we believe that this result provides basic information for making improvements in postural control and may be useful in balance training for fall prevention.

A Study on the Characteristics of Lower Extremity Muscle Activation according to the Variable Weight Shift on the Affected Side in Hemiplegic Patients (편마비 환자의 마비측으로의 다양한 중심이동에 따른 하지 근육 활성도 특성에 관한 연구)

  • Kim, Kyung-Hwan;Park, Sung-Hun;Pak, Noh-Wook;Lee, Hye-Jin
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.93-101
    • /
    • 2019
  • Purpose: This study aimed to investigate lower extremity muscle activation to the variable weight shift on the affected side of patients with hemiplegia. Methods: Eighteen patients with chronic hemiplegia volunteered to participate in this study. All participants performed three types of weight shift (sideways, forward, and backward) in limits of stability on the affected side. Muscle activation in a paralyzed leg was measured with electromyography on the gluteus medius, tensor fasciae latae, rectus femoris, and biceps femoris; furthermore, the attached area was recommended by SENIAM projects. Each weight shift was performed three times, and then the mean value of the three measurements was analyzed. The data were analyzed by measuring the symmetrically standing position with the reference voluntary contraction (RVC) and was standardized with the percentage of RVC method. Results: No significant difference in lower extremity muscle activation occurred according to the three types of variable weight shift. However, significant differences in lower extremity muscle activation did occur with each weight shift position. In addition, activation increased at the rectus femoris and decreased at the gluteus medius and tensor fasciae latae. Conclusion: Hip abductor muscle strength training and variable weight shifts on the affected side must increase to improve patients'balance and limits of stability.

Effects of Weight Distribution and Balance with Foot Orthotics in Hemiplegic Patients (편마비 환자에서 발 교정구의 적용이 체중분포과 균형에 미치는 영향)

  • Park, Seung-Kyu;Kang, Yang-Hun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.4
    • /
    • pp.241-246
    • /
    • 2012
  • Purpose: We investigated the effect of postural stability and balance with foot orthotics in hemiplegic patients. Methods: The subjects enrolled in this study were 16 hemiplegic patients who were examined for balance ability, weight distribution, and limits of stability with or without foot orthotics insole. Balance was measured according to a stance position by BIORESCUE: static balance open eyes (SEO), static balance close eyes (SEC), dynamic balance open eyes (DEO), dynamic balance close eyes (DEC), right and left weight distribution (RLWD), anterior and posterior weight distribution (APWD) and limit of stability (LOS). The data were analyzed with SPSS window version 18.0 (IBM Co., Armonk, NY, USA). Results: The results were of significant changes to the SEO (p<0.05), RLWD (p<0.05), APWD (p<0.05), and LOS (p<0.05). The SEC, DEO and DEC were not found to be statistically significant. Conclusion: It was found that foot orthotics affected the balance for hemiplegic patients. Therefore, it is thought to help fall prevention to measure the balance ability.

A State Feedback Controller Design for a Networked Control System with a Markov Delay (마코프 지연을 갖는 네트워크 제어 시스템을 위한 상태 궤환 제어기 설계)

  • Yang, Janghoon
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.549-556
    • /
    • 2020
  • This paper proposes several suboptimal methods of designing a controller for a networked control system with state feedback where delay due to transmission error and transmission delay is modeled as a Markov process. A stability condition for a control system with Markov delay is found through an equivalent relationship that corresponding delay-dependent Lyapunov-Krasovskii functional has the same form of the Lyapunov function of an augmented control system. Several suboptimal methods of designing a controller from the stability condition are proposed to reduce complexity. A simple numerical experiment shows that a restricted subspace method which limits the search space of a matrix variable to a block diagonal form provides the best tradeoff between the complexity and performance.

A study on the application of the critical strain concept by using the displacements occurring before excavation in tunneling (터널 선행변위를 활용한 한계변형률 개념의 적용 연구)

  • Park, Si-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.337-347
    • /
    • 2008
  • Critical strain is a new material property of the ground. Critical strain concept which was established in tunnel engineering can be applied to deformation limits in the ground due to tunneling by using the measured displacement at the tunnel construction site. In this study, quantitative evaluations for the tunnel stability are conducted by analysing the displacement results obtained at the construction field. Especially, critical stain concept was reviewed from a total displacement point of view using the displacements occurring before excavation. As a results, the variation characteristics of the tunnel stability are presented on the critical strain diagram with or without the preceeding displacements.

  • PDF

A Study on Flame Extinction Behavior in Downstream Interaction between SNG/Air Premixed Flames (SNG/Air 예혼합 화염들의 하류상호작용에 있어서 화염 소화 거동에 관한 연구)

  • Sim, Keunseon;Lee, Keeman
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.4
    • /
    • pp.48-60
    • /
    • 2016
  • Experimental and numerical studies were conducted to investigate flame behaviors near flammable limits for downstream-interacting SNG-air premixed flames in a counter-flow configuration. The SNG fuel consisted of a methane, a propane, and a hydrogen with volumetric ratios of 91, 6, and 3%, respectively. The most appropriate priority for some reliable reaction mechanisms examined was given to the mechanism of UC San diego via comparison of lean extinction limits attained numerically with experimental ones. Flame stability map was presented with a functional dependencies of lower and upper methane concentrations in terms of global strain rate. The results show that, at the global strain rate of $30s^{-1}$, lean extinction boundary is slanted while rich extinction one is relatively less inclined because of the dependency of such extinction boundary shapes on deficient reactant Lewis number governed by methane mainly. Further increase of global strain rate forces both extinction boundaries to be more slanted and to be shrunk, resulting in an island of extinction boundary and subsequently one flame extinction limit. Extinction mechanisms for lean and rich, symmetric and asymmetric extinction boundary were identified and discussed via heat losses and chemical interaction.

Determination of Acaricides in Honey by Solid-Phase Extraction and Gas Chromatography / Mass Spectrometry

  • Hong, Joo-Yeon;Jung, Ok-Sang;Ryoo, Jae-Jeong;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • An analytical method based on solid-phase extraction and gas chromatography / mass spectrometry has been developed for measurement of acaricides (amitraz, bromopropylate, coumaphos, cymiazole, and tetradifon) in honey sample. In the stability test of acaricides in honey, amitraz underwent a rapid degradation into 2,4-dimethylaniline (DMA), 2,4-dimethylphenylformamide (DMPF), and N-(2,4-dimethylphenyl)-N'-methylformamidine (DMPMF), whileas other acaricides were found to be stable even for over three months. Extraction of five acaricides from 5g of honey sample was carried out by liquid-liquid extraction using 20mL of ethylacetate. For purification, Florisil-SPE cartridge with elution of 5mL of n-hexane/ acetone (55:45, v/v) was found to remove interferences effectively. Quantification was performed using gas chromatography / mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery values from honey spiked at 0.02 and 0.20 ${\mu}g/g$ levels, respectively, were found to be greater than 75% for all acaricides. The method detection limits for acaricides were ranged from 0.1 to 3 ppb. The developed method in this study was applied for the monitoring of acaricides in honey products collected from urban markets in Korea.

UPFC Device: Optimal Location and Parameter Setting to Reduce Losses in Electric-Power Systems Using a Genetic-algorithm Method

  • Mezaache, Mohamed;Chikhi, Khaled;Fetha, Cherif
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Ensuring the secure operation of power systems has become an important and critical matter during the present time, along with the development of large, complex and load-increasing systems. Security constraints such as the thermal limits of transmission lines and bus-voltage limits must be satisfied under all of a system’s operational conditions. An alternative solution to improve the security of a power system is the employment of Flexible Alternating-Current Transmission Systems (FACTS). FACTS devices can reduce the flows of heavily loaded lines, maintain the bus voltages at desired levels, and improve the stability of a power network. The Unified Power Flow Controller (UPFC) is a versatile FACTS device that can independently or simultaneously control the active power, the reactive power and the bus voltage; however, to achieve such functionality, it is very important to determine the optimal location of the UPFC device, with the appropriate parameter setting, in the power system. In this paper, a genetic algorithm (GA) method is applied to determine the optimal location of the UPFC device in a network for the enhancement of the power-system loadability and the minimization of the active power loss in the transmission line. To verify our approach, simulations were performed on the IEEE 14 Bus, 30 Bus, and 57 Bus test systems. The proposed work was implemented in the MATLAB platform.

Optimal Tuning of Nonlinear Parameters of a Dual-Input Power System Stabilizer Based on Analysis of Trajectory Sensitivities (궤도민감도 분석에 기반하여 복입력 전력시스템 안정화 장치(Dual-Input PSS)의 비선형 파라미터 최적화 기법)

  • Baek, Seung-Mook;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.915-923
    • /
    • 2008
  • This paper focuses on optimal tuning of nonlinear parameters of a dual-input power system stabilizer(dual-input PSS), which can improve the system damping performance immediately following a large disturbance. Until recently, various PSS models have developed to bring stability and reliability to power systems, and some of these models are used in industry applications. However, due to non-smooth nonlinearities from the interaction between linear parameters(gains and time constants of linear controllers) and nonlinear parameters(saturation output limits), the output limit parameters cannot be determined by the conventional tuning methods based on linear analysis. Only ad hoc tuning procedures('trial and error' approach) have been used. Therefore, the steepest descent method is applied to implement the optimal tuning of the nonlinear parameters of the dual-input PSS. The gradient required in this optimization technique can be computed from trajectory sensitivities in hybrid system modeling with the differential-algebraic-impulsive-switched(DAIS) structure. The optimal output limits of the dual-input PSS are evaluated by time-domain simulation in both a single machine infinite bus(SMIB) system and a multi-machine power system in comparison with those of a single-input PSS.

Biophysical therapy and biostimulation in unfavorable bony circumstances: adjunctive therapies for osseointegration

  • Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.195-203
    • /
    • 2012
  • Dental implants using titanium have greatly advanced through the improvement of designs and surface treatments. Nonetheless, the anatomical limits and physiological changes of the patient are still regarded as obstacles in increasing the success rate of implants further, even with the enhancement of implant products. So there have been many efforts to overcome these limits. The intrinsic potential for bone regeneration can be stimulated through adjuvant treatments with the continuous improvement of implant properties, and this can play an important role in achieving optimum osseointegration toward peripheral bone tissue and securing ultimate long-term implant stability in standard surgical procedures. For this purpose, various chemical, biological, or biophysical measures were developed such as bone grafts, materials, pharmacological agents, growth factors, and bone formation proteins. The biophysical stimulation of bone union includes non-invasive and safe methods. In the beginning, it was developed as a method to enhance the healing of fractures, but later evolved into Pulsed Electromagnetic Field, Low-Intensity Pulsed Ultrasound, and Low-Level Laser Therapy. Their beneficial effects were confirmed in many studies. This study sought to examine bone-implant union and its latest trend as well as the biophysical stimulation method to enhance the union. In particular, this study suggested the enhancement of the function of cells and tissues under a disadvantageous bone metabolism environment through such adjunctive stimulation. This study is expected to serve as a treatment guideline for implant-bone union under unfavorable circumstances caused by systemic diseases hampering bone metabolism or the host environment.