• Title/Summary/Keyword: limiting normal

Search Result 184, Processing Time 0.025 seconds

FRAPCON analysis of cladding performance during dry storage operations

  • Richmond, David J.;Geelhood, Kenneth J.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.2
    • /
    • pp.306-312
    • /
    • 2018
  • There is an increasing need in the United States and around the world to move used nuclear fuel from wet storage in fuel pools to dry storage in casks stored at independent spent fuel storage installations or interim storage sites. Under normal conditions, the Nuclear Regulatory Commission limits cladding temperature to $400^{\circ}C$ for high-burnup (>45 GWd/mtU) fuel, with higher temperatures allowed for low-burnup fuel. An analysis was conducted with FRAPCON-4.0 on three modern fuel designs with three representative used nuclear fuel storage temperature profiles that peaked at $400^{\circ}C$. Results were representative of the majority of US light water reactor fuel. They conservatively showed that hoop stress remains below 90 MPa at the licensing temperature limit. Results also show that the limiting case for hoop stress may not be at the highest rod internal pressure in all cases but will be related to the axial temperature and oxidation profiles of the rods at the end of life and in storage.

Mechanistic Significances of the Reactivity-Selectivity Principle

  • Lee, Ik Jun;Lee, Bon Su;Go, Han Jung;Jang, Byeong Du
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.277-281
    • /
    • 1995
  • The relationship between the signs of ${\rho}i(0)$, ${\rho}j(0)$ and ${\rho}ij$ and validity of the reactivity-selectivity principle (RSP) has been derived: RSP is valid when W = ${\rho}i(0){\cdot}{\rho}j(0)/{\rho}ij$ is negative. The analysis of 100 reaction series indicated that for normal SN2 reactions involving variations of substituents in the nucleophile (X) and in the substrate (Y) RSP is valid only for a dissociative type for which ${\rho}Y(0)$ is negative, whereas for the acyl transfer reactions with rate-limiting breakdown of the tetrahedral intermediate RSP is valid in general for all substituent changes, X, Y and/or Z (substituent on the leaving group). The trends in the validity of RSP for certain types of reaction can be useful in supplementing the mechanistic criteria based on the signs of ${\rho}i(0)$, ${\rho}j(0)$ and ${\rho}ij$.

Hysteresis Characteristics of Flux-Lock Reactor using HTSC (고온초전도체를 이용한 자속구속 리액터의 히스테리시스 특성)

  • Lim, Sung-Hun;Choi, Hyo-Sang;Ko, Seok-Cheol;Lee, Jong-Hwa;Park, Sick;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.89-91
    • /
    • 2003
  • For the design to prevent the saturation of iron core and the effective fault current limitation, the analysis for the operation of the flux-lock type superconducting fault current limiter (SFCL) with consideration for the hysteresis characteristics of iron core is required. In this paper, the hysteresis characteristics of flux-lock reactor, which is an essential component of flux-lock type SFCL, was investigated. The hysteresis loss of iron core in flux-lock type SFCL does not happen due to its winding's structure especially in the normal state. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the analysis for both the hysteresis curves and the fault current limiting characteristics due to the number of turns for the 1st and 2nd winding, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.

  • PDF

Increase of Operational Current in a SFCL using Series or Parallel Coupling of Coils (코일의 직.병렬결합을 이용한 초전도 사고전류제한기의 동작전류 증가)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.46-51
    • /
    • 2007
  • The fault current limiting characteristics of superconducting fault current limiter(SFCL) using magnetic coupling of two coils were investigated. This SFCL consists of a high-TC superconducting(HTSC) element and two coils with series or parallel connection on the same iron. In normal time, the inner magnetic fluxes generated by two coils are canceled in case that the HTSC element keeps superconducting state. However, in case that the resistance of the HTSC element happens by a short-circuit the magnetic fluxes, not cancelled, induce the voltages across two coils and the fault current can be limited by the impedance of this SFCL. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the operating current of this SFCL increased more than that of HTSC element's independent operation.

Characteristics according to the spot at the beginning of the fault current (개선된 자속구속형 전류제한기의 사고 시점에 따른 사고전류제한 특성)

  • Kim, Yong-Jin;Du, Ho-Ik;Lee, Dong-Hyeok;Han, Sang-Chul;Lee, Jeong-Phil;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.189-189
    • /
    • 2010
  • The Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO coated conductor was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics through the spot at the beginning of the fault current in the Improved flux-lock type SFCL. The experiment results that the fault current limiting characteristics was difference according to the point of a fault current started. Through the analysis, it was shown that shorter the time of a phase transition.

  • PDF

Protecting E-mail Server with Class-Based Rate Limiting Technique (클래스 기반의 대역 제한 기법을 통한 이메일 서버의 보호)

  • Yim, Kang-Bin;Lee, Chang-Hee;Kim, Jong-Su;Choi, Kyung-Hee;Jung, Gi-Hyun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.6 s.324
    • /
    • pp.17-24
    • /
    • 2004
  • This paper proposes an efficient technique to protect e-mail server from DDoS attack using the CBQ (Class Based Queuing) algorithm The proposed method classifies incoming trafic to an e-mail server into three classes: 'more important mail traffic', 'less important traffic' and 'unknown traffic' and assigns bandwidths differently to the traffics. By differentiating the bandwidths of classes, normal mail traffic may flow even under DDoS attack in the proposed technique. The proposed technique is implemented on an embedded system which hires a switching processor with the WFHBD(Weighted Fair Hashed Bandwidth Distribution) engine that has been known as an efficient algorithm to distribute a given bandwidth to multiple sources, and it is verified that it can be an efficient way to protect e-mail server from DDoS attack.

Analysis of Quench Generation in Fault Types According to Inductance Variation in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (삼상일체화된 자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 사고유형별 퀜치발생 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.165-166
    • /
    • 2005
  • In this paper, we investigated the quench generation of HTSC elements in fault types according to inductance variation in the integrated three-phase flux-lock type SFCL. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

Statistical Analysis on Water Quality Characteristics of Large Lakes in Korea (우리나라 주요 호소의 수질특성에 대한 통계적 분석)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.2
    • /
    • pp.165-180
    • /
    • 2019
  • Water quality data of 81 lakes in Korea, 2013 ~ 2017 were analyzed. Most water quality parameters showed left-skewed distribution, while dissolved oxygen showed normal distribution. pH and dissolved oxygen showed a positive correlation with organic matter and nutrients, which appeared to be a nonsense correlation mediated by the algae. The ratio of $BOD_5$ and $COD_{Mn}$ to CBOD was 21 % and 52 % in the freshwater lakes, respectively. TOC concentration appeared to be underestimated by the UV digestion method, when salinity exceeds $700{\mu}S\;cm^{-1}$. In terms of nitrogen/phosphorus ratio, the limiting factor for algal growth seemed to be phosphorus in most of the lakes. Chlorophyll ${\alpha}$ increased acutely with decrease of N/P ratio. However, it seemed to be a nonsense correlation mediated by phosphorus concentration, since the N/P ratio depended on phosphorus. The N/P ratio of brackish lakes was lower than that of the freshwater, at the same concentration of phosphorus. It is worth examining denitrification that occurs, in bottom layer and sediment, during saline stratification. $Chl.{\alpha}$ concentration decreased in the form of a power function with increase of mean depth. The primary reason is that deep lakes are mainly at the less-disturbed upstream. However, it is necessary to investigate the effect of sediment, on water quality in shallow lakes. Light attenuation in the upper layer, was dominated by tripton (non-algal suspended solids) absorption/scattering (average relative contribution of 39 %), followed by CDOM (colored dissolved organic matter) (average 37 %) and $Chl.{\alpha}$ (average 21 %).

Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions (Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로)

  • Jeong, Hee-Seong;Park, Do-Il;Lee, Yong-Hwi;Lee, Chang-Hyeon;Rho, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.

Fault Current Limiting Characteristic of Non-inductively Wound HTS Magnets in Sub-cooled $LN_2$ Cooling System

  • Park Dong-Keun;Ahn Min-Cheol;Yang Seong-Eun;Lee Chan-Joo;Seok Bok-Yeol;Yoon Yong-Soo;Ko Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.2
    • /
    • pp.29-32
    • /
    • 2006
  • An advanced superconducting fault current limiter (SFCL) using $high-T_c$ superconducting (HTS) wire has been developed. The SFCL has a non-inductively wound magnet for reducing loss in normal state. Two types of non-inductively wound magnets, the solenoid type and the pancake type, were designed and manufactured by using Bi-2223 wire in this research. Short-circuit tests of the magnets were performed in sub-cooled $LN_2$ cooling system of 65 K. The magnets are thermally more stable and have a higher critical current in 65 K sub-cooled $LN_2$ cooling system than in 77 K saturated one. Because the resistivity of matrix at 65 K is lower than the resistivity at 77 K, the magnets generate a small resistance to reduce the fault current when the quench occurs. The magnets could limit the fault current to low current level with such a small resistance. The current limiting characteristic of the magnets was analyzed from the test result. The solenoid type was wound in parallel to make it non-inductive. The pancake type was also connected in parallel to be compared with the solenoid type in the same condition. The solenoid type was found to have a good thermal stability compared with the pancake type. It also had as large resistance as the pancake type to limit the fault current in sub-cooled $LN_2$ cooling system.