• 제목/요약/키워드: limiting load

검색결과 173건 처리시간 0.022초

Plastification procedure of laterally-loaded steel bars under a rising temperature

  • Huang, Zhan-Fei;Tan, Kang-Hai;England, George L.
    • Structural Engineering and Mechanics
    • /
    • 제35권6호
    • /
    • pp.699-715
    • /
    • 2010
  • This paper investigates the structural responses of axially restrained steel beams under fire conditions by a nonlinear finite element method. The axial restraint is represented by a linear elastic spring. Different parameters which include beam slenderness ratio, external load level and axial restraint ratio are investigated. The process of forming a mid-span plastic hinge at the mid-span under a rising temperature is studied. In line with forming a fully plastic hinge at mid-span, the response of a restrained beam under rising temperature can be divided into three stages, viz. no plastic hinge, hinge forming and rotating, and catenary action stage. During catenary action stage, the axial restraint pulls the heated beam and prevents it from failing. This study introduces definitions of beam limiting temperature $T_{lim}$, catenary temperature $T_{ctn}$ and warning time $t_{wn}$. Influences of slenderness ratio, load level and axial restraint ratio on $T_{lim}$, $T_{ctn}$ and $t_{wn}$ are examined.

무유도성 초전도전류제한기의 특성 해석 및 컴퓨터 시뮬레이션 (The Computer Simulation on the Characteristics of the Non-Inductive Superconducting Fault Current Limiter)

  • 주민석;이상진;오윤상;고태국
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1050-1060
    • /
    • 1994
  • This paper is a study on the computer simulation of the characteristics of the superconducting fault current limiter. Input variable parameters are apparent power, load resistance value, line resistance value and so on. Initial fault current 2 times larger than the trigger current is required to reduce the switching time of SFCL. The propagation velocity increases abruptly, the transport current is several times larger than the ciritical current. In this paper, the switching time is calculated to be 323$\mu$ sec, and the initial fault current is 19 times larger than the critical current. Because the trigger coils are bifilar winding, they have little impedance in superconducting state. After fault occurred, the limiting coil acts as a superconducting reactor and the trigger coils quench at a critical current. Without the SFCL in the circuit, fault current after the load impedence is shorted might be increased to 1100A. The fault current is, therefore, successfully limited by the superconducting limiting coil to 100A determined by the coil inductance.

  • PDF

ESTIMATION OF REQUIRED CAPACITY OF SHUNT TYPE ACTIVE POWER FILTER WITH A THYRISTOR CONVERTER LOAD

  • Jeong, Seung-Gi;Kim, Dong-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.802-807
    • /
    • 1998
  • The main drawback of parallel type active power filters (APF) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement of harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. And it is shown that the APF capacity can be considerably reduced while slightly sacrificing the filtering performance by deliberately limiting the peak current of the APF.

  • PDF

수용가용 직접부하제어장치 설계 (Design of Direct Load Controller for use of Demand Side)

  • 박종찬;김한구;정병환;강병희;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.149-151
    • /
    • 2005
  • Recently, power supply-demand instability due to the dramatic increase in power usage suchas air-conditioning load at summertime has brought forecasts of decrease in power supply capability. Therefore improving the load factor through systematic load management, in other words, Direct Load Control became necessary. Direct Load Control(DLC) system is kind of a load management program for stabilization of electric power supply-demand. It's purpose is limiting the demand of the demand side selected at peak load or other time periods. The paper presented a Design of Direct Load Controller for control the amount of power demand in demand side. The proposed Controller is cheaper and has ability of storing more power data than pre-existing device.

  • PDF

단면절삭형 응력제한 장치의 개발에 관한 연구 (A Study on the Development of Force Limiting Devices of Cross-Section Cutting Types)

  • 김철환;채원탁
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.77-85
    • /
    • 2015
  • 본 연구에서는 세장한 부재가 압축력을 받을 경우 발생하는 횡좌굴에 의한 내력의 저하를 방지하기 위해, 좌굴 전에 항복을 유도하는 응력제한장치의 개발에 관한 것으로서, 기존의 면외저항방식 및 슬롯방식과는 상이한 단면절삭방식을 제안하고 그 유효성을 실험적, 해석적으로 규명하고 있다. 단면절삭방식은 단면의 절삭범위에 따라 역학적 특성 및 구조적 성능이 상이한 것으로서, 연구의 대상은 절삭의 폭 및 절삭개수를 주 대상으로 하고 있다. 연구결과, 단면 깊이가 같은 경우 단면 절삭폭의 영향은 나타나지 않았으며, 단면 절삭폭을 좁게, 절삭개수가 많을수록 소성영역에서 좀 더 안정적인 거동을 나타내었다. 따라서, 단면절삭을 이용한 응력제한 장치는 항복 후 안정된 이력거동을 나타내고 있어 응력제한 장치로서 그 유효성이 확인되었으며, 향후 실 구조물에의 적용이 가능하리라 판단된다.

Operational Characteristics of a Flux-Lock Type SFCL Integrated with Voltage-Controlled Voltage Source Inverter

  • Lee, Su-Won;Lim, Sung-Hun;Ko, Sung-Hun;Lee, Seong-Ryong
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.546-551
    • /
    • 2008
  • In this paper, a flux-lock type superconducting fault current limiter(SFCL) integrated with a voltage-controlled voltage source inverter(VC-VSI) is proposed. The suggested equipment, which consists of a flux-lock type SFCL and a VCVSI, can perform the fault current limiting operation from the occurrence of a short-circuit. In addition, it can compensate the reactive power that the non-linear load requires and also perform the uninterruptible power supply(UPS) as well as the load voltage stabilization by controlling the amplitude and the phase of the inverter's output voltage. The specification for a test model was determined and its various functions such as the fault current limiting and the power conditioning operations were presented and analyzed via computer simulation. Through the analytical results based on the computer simulation, the validity of the analysis was confirmed and its multi-operation was discussed.

소변형 이론에 입각한 감육이 존재하는 90 도 곡관의 소성 한계 하중 (II)- 굽힘 - (Plastic Limit Loads of 90° Elbows with Local Wall-Thinning Using Small Strain FE Limit Analyses (II)- Bending Moment -)

  • 김종현;안중혁;홍석표;박치용;김윤재
    • 대한기계학회논문집A
    • /
    • 제31권4호
    • /
    • pp.496-505
    • /
    • 2007
  • This paper proposes closed-form plastic limit load solutions for elbows under in-plane bending, via three-dimensional (3-D), small strain FE limit analyses using elastic-perfectly plastic materials. A wide range of elbow and thinning geometries are considered. For systematic analyses of the effect of the axial thinning length on limit loads, two limiting cases are considered; a sufficiently long wall thinning, and the circumferential part-through surface crack. Closed-form plastic limit load solutions for wall thinning with intermediate longitudinal extents are then obtained from these two limiting cases. The effect of the axial extent of wall thinning on plastic limit loads for elbows is highlighted by comparing that for straight pipes. Although the proposed solutions are developed for the case when wall thinning exists in the center of elbows, it is also shown that they can be applied to the case when wall thinning exists anywhere within the elbow.

Comparative study on the behavior of lime-soil columns and other types of stone columns

  • Malekpoor, Mohammadreza;Poorebrahim, Gholamreza
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.133-148
    • /
    • 2014
  • An experimental study is carried out to evaluate the performance of Lime mortar-Well graded Soil (Lime-WS) columns for the improvement of soft soils. Tests are conducted on a column of 100 mm diameter and 600 mm length surrounded by soft soil in different area ratios. Experiments are performed either with the entire area loading to evaluate the load - settlement behavior of treated grounds and only a column area loading to find the limiting axial stress of the column. A series of tests are carried out in soaking condition to investigate the influence of moisture content on the load - settlement behavior of specimens. In order to compare the behavior of Lime-WS columns with Conventional Stone (CS) columns as well as Geogrid Encased Stone (GES) columns, the behavior of these columns have been also considered in the present study. Remarkable improvement in the behavior of soft soil is observed due to the installation of Lime-WS columns and the performance of these columns is significantly enhanced by increasing the area ratio. The results show that CS columns are not suitable as a soil improvement technique for extremely soft soils and should be enhanced by encasing the column or replaced by rigid stone columns.

수용가용 직접부하제어시스템의 구성 및 운영 (Composition and Operation of Direct Load Control(DLC) System for use of Demand Side)

  • 박종찬;최문규;이용균;김선자;정병환;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1260-1262
    • /
    • 2004
  • Direct Load Control(DLC) system is a load management program for stablization of electric power supply-demand. It is a series of acts limiting the demand of selected demand side at peak load or other time periods. Recently, power supply-demand instability due to dramatic increase in power usage such as summertime air-conditioning load has brought forecasts of decrease in power supply capability. Therefore heightening the load factor through systematic load management, in other words, Direct Load Control became necessary. By examining the composition and operation of the DLC system, this paper provides conceptional understanding of the DLC system and help in system research.

  • PDF

넓은 부하범위에서 고효율 특성을 갖는 역율개선회로의 PWM 제어기 (PWM Controller of Power Factor Correction Circuit to Improve Efficiency for Wide Load Range)

  • 손민수;김홍중;박귀철;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.75-76
    • /
    • 2016
  • This paper proposes a power factor correction circuit with a high efficiency over a wide load range characteristics for a communication power supply. And the characteristic verification is applied to produce a design of prototype. Power factor correction circuit can reduce conduction losses by applying Bridgeless Boost Converter for efficiency. Over a wide load range to maintain the efficient, the control method of a PWM controller is divided by two sections according to the load area. In the low-load region, it was reduced switching losses by applying the critical conduction mode control method. On the other hand, in the heavy-load area, the hysteresis current control method is used to maintain the high efficiency over a wide load range by limiting the peak noise of the inductor.

  • PDF