• Title/Summary/Keyword: limitation

Search Result 8,420, Processing Time 0.031 seconds

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

A Path Analysis Model of Health-Related Quality of Life in Patients with Heart Failure (심부전 환자의 건강관련 삶의 질 경로분석 모형)

  • Kim, Yong Suk
    • Korean Journal of Adult Nursing
    • /
    • v.19 no.4
    • /
    • pp.547-555
    • /
    • 2007
  • Purpose: The purpose of this study was to test a hypothetical model of health-related quality of life in patients with heart failure. The hypothetical model was derived from the Wilson and Cleary's model, the Rector's model, and published research findings. Methods: Data from 103 patients with heart failure were analyzed to determine the best multivariate health-related quality of life model given variables derived from the prior studies. The statistics programs SPSS 12.0 and LISREL 8.7 program were used for descriptive statistics and covariance structure analysis respectively. Results: The overall fitness of the path final model was good(GFI=.97, AGFI=.95, NNFI=1.06, NFI=.96, p=.96). Symptoms were directly affected by gender. HYHA Class was directly affected by only gender. Physical functioning limitation was directly affected by exercise. Health perception was directly affected by economics, symptom, and physical functioning limitation. Depression was directly affected by exercise and health perception. Heath-related quality of life was directly affected by physical functioning limitation and depression, indirectly affected by gender, economics, exercise, symptoms, NYHA Class, and health perception. This path analysis model explained 51% of health-related quality of life in patients with heart failure. Conclusion: To improve of health-related quality of life with heart failure patients, it is necessary to make nursing interventions for physical functioning and depression.

  • PDF

Air-water Countercurrent Flow Limitation in Narrow Rectangular Channels (협소 사각유로에서 공기-물 대향류 유동한계)

  • Kim, Byong-Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.441-446
    • /
    • 2007
  • An experimental study on the countercurrent two-phase flow in narrow rectangular channels has been peformed. Countercurrent flow limitation (CCFL) was investigated using air and water in 760mm long, 100mm wide, vertical test sections with 1 and 3mm channel gaps. Tests were systematically performed with downward liquid superficial velocities and upward gas velocities covering 0 to 0.125 and 0 to 3.5m/s ranges, respectively. As the gap width of rectangular channel increased the CCFL water superficial velocity decreased for the given air superficial velocity. Slight increase of the air superficial velocity resulted in the abrupt decrease of water velocity when $j_g=2{\sim}4m/s$. The critical superficial velocity of air, at which the downward flow of water was no longer allowed, also decreased with the increase of gap width. The experimental results were compared with the previous correlations, which were mainly for round tubes, and the qualitative trends were found to be partially acceptable. However the quantitative discrepancies were hardly neglected. New correlation of CCFL was developed and showed good agreement with the experimental data.

Health Problem and Joint Bleeding, Limitation according to Severity in Patients with Hemophilia (혈우병 환자의 중증도에 따른 건강문제와 관절출혈 및 장애)

  • Kang, Hyun-Sook;Kim, Won-Ok;Song, Young-A
    • Journal of muscle and joint health
    • /
    • v.11 no.2
    • /
    • pp.119-126
    • /
    • 2004
  • Purpose: The purpose of this study was to identify health problem and joint bleeding, disability according to severity in patients with hemophilia. Method: The research design was survey study for conformed severity in patients with hemophilia, health problem and bleeding of joint and degree of limitation. The subjects were 186 men in patients with hemophilia by convenience sampling. These results were analyzed statistically by frequency, percentage, t-test, chi-square. Result: 1. Health problem of severe hemophilia patients were significantly higher than moderate group(t=3.17, p=.002). A severe hemophilia patients were significantly higher than moderate group in health problem of socio-psychological, emotional, physical, interpersonal. 2. There was relation between severity and the frequency of bleeding($X^{2}=7.642$, p=.054). 3. A severe hemophilia patients were more than moderate group in disability of ankle joint(t=2.52, p=.013). Conclusion: A severe hemophilia patients has more severe problems than moderate patient in case of health problem, joint bleeding and degree of disability.

  • PDF

Finite element analysis of the fluid-structure interaction in a compliant vessel (유연 혈관에서 유체-고체 상호작용에 대한 유한요소 해석)

  • Shim, Eun-Bo;Ko, Hyung-Jong;Kamm, Roger D.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.591-596
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. Two models are examined: a planar two-dimensional channel, and an axisymmetric tube. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and compared to existing experimental data. Computational results for an axisymmetric tube show that as cross-sectional area falls with a reduction in downstream pressure, flow rate increases and reaches a maximum when the speed index (mean velocity divided by wave speed) is near unity at the point of minimum cross-section area, indicative of wave speed flow limitation or "choking" (flow speed equals wave speed) in previous one-dimensional studies. For further reductions in downstream pressure, flow rate decreases. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is ${\le}$ 2 the area throat is located near the downstream end; as wall taper is increased to ${\ge}$ 3 the constriction moves to the upstream end of the tube. In the planar two-dimensional channel, area reduction and flow limitation are also observed when outlet pressure is decreased. In contrast to the axisymmetric case, however, the elastic wall in the two-dimensional channel forms a smooth concave surface with the area throat located near the mid-point of the elastic wall. Though flow rate reaches a maximum and then falls, the flow does not appear to be choked.

  • PDF

Joint Pain in Patients with Osteoarthritis: Based on the 5th KNHNES (우리나라 골관절염 환자의 관절통증: 2012년 국민건강영양조사 자료를 이용하여)

  • Lee, Jinsook
    • Journal of muscle and joint health
    • /
    • v.23 no.3
    • /
    • pp.152-158
    • /
    • 2016
  • Purpose:The purpose of this study was to examine the degree of joint pain, limitation of daily activities, and frequency of outpatient visits. Methods: This secondary analysis study used the data from the fifth Korean National Health and Nutrition Examination Survey (KNHNES). The data about general characteristics, prevalence and treatment of osteoarthritis, limitation of activities of daily living (ADL) and frequency of outpatient visits and hospitalization in 424 osteoarthritis patients over 50 years old were derived from the database. Data were analyzed with complex samples in SPSS ver. 20.0. Results: Among people with knee joint pain, 79.3% reported they had more than 4 out of 10 points of the degree of pain. Meanwhile, 97.3% of people with hip joint pain reported that they had more than 4 out of 10 points of the degree of pain. People reporting 10 out of 10 point of pain were 21.4% of those with knee joint pain and 25% of those with hip joint pain. The mean of the degree of knee joint pain was 6.35, and the mean of the degree of hip joint pain was 6.89 out of 10 points. About 50% of people with osteoarthritis visited an outpatient clinic within the last 2 weeks, and 27% had limitation of ADL. Conclusion: It is necessary to develop an integrated intervention program to improve quality of life in patients with osteoarthritis.

Clinical Features of the Temporomandibular Disorder Patients with Occlusal Splint Therapy (교합장치요법으로 치료한 측두하악장애 환자의 임상적 연구)

  • Song, Jae-Chul;Chin, Byung-Rho
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.316-324
    • /
    • 1998
  • This study was performed to evaluate the clinical features and treatment results on 55 temporomandibular disorder patients who had treated by conservative treatment using occlusal splint. The results were as follows; 1. The ratio of men to women was about 1:2.2 and most of the patients were second and third decades. 2. Pain was the most frequent symptom, followed by clicking and mouth opening limitation. 3. The number of acute and chronic groups on the basis of 6 months duration of symptoms were similar. 4. Most of patients had Angle's Class 1 molar relationships(78.2%), followed by Class 3 and Class 2. 5. Centric Relation splints were used alone for treatment of 34 patients and 21 patients were treated with Centric Relation splints and Anterior Repositioning splints. The treatment duration of the patients who had complained pain was average 9.8 weeks and 6 patients of them had slight pain continuously during follow-up. 6. Eleven patient's maximum mouth opening who had mouth opening limitation was improved from 30. 7mm to 43.0mm during procedures.

  • PDF

Dynamics of alpine treelines: positive feedbacks and global, regional and local controls

  • Kim, Jong-Wook;Lee, Jeom-Sook
    • Journal of Ecology and Environment
    • /
    • v.38 no.1
    • /
    • pp.1-14
    • /
    • 2015
  • Whilst it is clear that increasing temperatures from global environmental change will impact the positions of alpine treelines, it is likely that a range of regional and local scaled factors will mediate the overall impact of global scale climate drivers. We summarized 12 categories of abiotic and biotic factors as 4 groups determining treeline positions. First, there are global factors related to climate-induced growth limitation and carbon limitation. Second, there are seven regional and local factors related to treeline dynamics including frost stress, topography, water stress, snow, wind, fire and non-fire disturbance. Third, species-specific factors can control treeline dynamics through their influence on reproduction and life history traits. Fourth, there are positive feedbacks in structuring the dynamics of treelines. Globally, the commonly accepted growth limitation hypothesis is that growth at a treeline is limited by temperature. Meanwhile, positive feedbacks between canopy cover and tree establishment are likely to control the spatial pattern and temporal dynamics of many treelines. The presence of non-linear dynamics at treelines has implications for the use of treelines as barometers of climate change because the lagged responses and abrupt shifts inherent in non-equilibrium systems may combine to mask the overall climate trend.

Investigation of Network Application of the Hybrid SFCLs (복합형 초전도 한류기의 한류특성에 따른 계통 적용성 검토)

  • Choe, Won-Joon;Sim, Jung-Wook;Park, Kwon-Bae;Kim, Young-Gun;Oh, Il-Sung;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.223-225
    • /
    • 2008
  • In order to apply SFCLs into electric power systems, the urgent issues to be settled are as follows, such as initial installation price, operation and maintenance cost due to ac loss of superconductor and the life of cryostat, and high voltage and high current problems. We designed novel hybrid SFCLs which combine superconductor and conventional electric equipments including a vacuum interrupter, an electro-magnetic contactor and a current limiting reactor. The main purpose of the hybrid SFCL is to drastically reduce total usage of superconductor by adopting current commutation method by use of the superconductor and the fast switch. According to protective coordination and performance, we investigated two concepts of Hybrid SFCLs. First is a half cycle fault current limitation type and second is a non-half cycle fault current limitation type. We concluded that the non-half cycle fault current limitation type is batter than the other.

  • PDF

The Effects of Spinal Stabilization Exercise using Gravity on patients with Degenerative Disc Disease (중력을 이용한 요부안정화 운동이 만성요통을 가진 노인환자에게 미치는 영향)

  • Kim, Hee-Ra;Kim, Yoon-Shin
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.23-31
    • /
    • 2008
  • Purpose: The purpose of this study was finding out the effects of spinal stabilization exercise using Centaur which is a 3D spinal stabilization sports implement on Chronic low back pain patients over 8 weeks. Methods: 30 patients with DDD were observed during the study. Their average age was 66.88years, height was 152.12cm and average weight was 58.91kg, 4 males and 26 females were involved. 8 various investigations were performed and varied values were compared with reinvestigation done after having exercised 8 weeks using 3-D CENTAUR We used VAS(visual analog scale) in order to see the variation of pain intensity, MOI(modified oswestry index) in order to see limitation of daily life. Results: VAS was lessened from 7.57 to 2.63, limitation of routine life(MOS) from 23.48 to 11.30, there were remarkable differences statistically(p<0.05). As a result of muscular investigation for static spinal stabilization by 8 variations of body deflection, muscular strength were all increased and there were signigicant differences statistically(p<0.05). Conclusion: It has turned out that pain and limitation of routine life was lessened, as a result of 8 weeks exercise using CENTAUR, and deep muscular power was increased. Thus it has turned out that 3-D spinal stabilization exercise has an effect on the strengthening spinal muscles and alleviation of their pain for old patients with DDD.

  • PDF