• 제목/요약/키워드: limit of quantitation

검색결과 276건 처리시간 0.021초

Determination of Cadmium, Chromium and Lead in Polymers by ICP-OES Using a High Pressure Asher (HPA)

  • Cho, Hong-Je;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권2호
    • /
    • pp.489-497
    • /
    • 2011
  • The proposed method for an effective assay of Cd, Cr and Pb in several polymer samples has been validated. The determination was carried out using ICP-OES after a high pressure asher (HPA) digestion at pressure and temperatures up to 13 MPa and $320^{\circ}C$, respectively. Polymer based materials were totally oxidized with nitric acid in a HPA chamber and determined by ICP-OES. Validation parameters such as linearity, matrix effect, limit of dectection (LOD), limit of quantitation (LOQ), accuracy and precision (repeatibility, intermediate precision and reproducibility) were assessed. The LOD and LOQ in the sample were ranged from 0.98 to 1.18 mg $kg^{-1}$ and 2.93 to 3.55 mg $kg^{-1}$, respectively, relying on the analyte. The proposed method had a good accuracy and precision for repeatability, intermediate precision with respect to days and analysts and reproducibility expressed as inter-laboratory study. The developed method was simple to use, suitable and applicable to various kinds of polymers.

Development of Highly Sensitive Analytical Method for Evaluation of Evening Primrose Oil's Enhancing Effect in Prostaglandin E1(OP 1206) Biosynthesis

  • Lee, Sung-Hoon
    • 인간식물환경학회지
    • /
    • 제21권6호
    • /
    • pp.485-492
    • /
    • 2018
  • This study aimed to develop and validate highly sensitive determination method of a prostaglandin ($PGE_1$, OP 1206) in human plasma by LC-MS/MS using column switching. Plasma stored at $-30^{\circ}C$ and treated with methanol effectively inhibited interferences synthesized post-sampling. Samples were added with internal standard and were separated by reversed-phase HPLC with a cycle time of 30min. The method was selective for OP 1206 and the regression models, based on internal standard, were linear across the concentration range 0.5-50 pg/mL with the limit of quantification of 0.5 pg/mL (limit of quantitation, LOQ) for OP 1206. The calibration curve of OP 1206 standards spiked in five individual plasma samples was linear ($r^2=0.9999$). Accuracy and precision at the concentrations of 0.5, 1.5, 5.0 and 40 pg/mL, and at the lower LOQ of 0.5 pg/mL were excellent at 20%. OP120 < 6 was stable in plasma samples for at least 24 hours at room temperature, 24 hours frozen at $-70^{\circ}C$, 24 hours in an auto sampler at $6^{\circ}C$, and for two freeze/unfreezing cycles. The validated determination method successfully quantified the concentrations of OP 1206 in plasma samples from simulated administrating a single $5{\mu}g$ OP 1206 formulation. Thus, this novel LC-MS/MS technique for drug separation, detection and quantitation is expected to become the standard highly-sensitive detection method in bioanalysis and to be applied to many low dose pharmaceutical products.

LC-MS/MS를 이용한 소의 근육과 간 중에 잔류하는 glucocorticoids 동시 분석 (Simultaneous analysis of glucocorticoids in bovine muscle and liver by LC-MS/MS)

  • 신상은;조현우;명승운
    • 분석과학
    • /
    • 제23권4호
    • /
    • pp.405-413
    • /
    • 2010
  • 축산물(소의 근육 및 간)중에 잔류하는 합성 글루코코티코이드 6종 (betamethasone, dexamethasone, prednisone, prednisolone, methylprednisolone, flumethasone)에 대한 동시분석방법을 확립하였다. 효과적인 기기분석을 위해서 시료는 C18 고체상 카트리지를 사용하여 에틸아세테이트 용매를 사용하여 추출/정제하였다. C18 컬럼을 사용하여 분리한 후 음이온 전기분무 질량분석법의 multiple reaction monitoring 방법을 사용하여 정량 및 정성 분석을 수행하였다. 효과적이고 감도있는 HPLC-MS/MS 분석을 위해서 0.1% 포름산이 포함된 물과 아세토나이트릴이 이동상 용매로 사용되었다. 메트릭스와 약물의 종류에 따라서 검출한계(LOD)는 $0.2-0.1\;{\mu}g$/kg, 정량한계(LOQ)는 $0.8-3.4{\mu}g$/kg 이었으며, 회수율은 89.5-119.6%이었다. 확립된 기존의 방법들에 비해 6종의 글루코코티코이드의 동시분석 방법이 간소화되었고, 좋은 정확도, 정밀도 및 회수율을 나타내었으며, 축산 육류 중에 잔류하는 글루코코티코이드들 분석하는데 사용될 수 있을 것이다.

Validation of One-Step Real-Time RT-PCR Assay in Combination with Automated RNA Extraction for Rapid Detection and Quantitation of Hepatitis C Virus RNA for Routine Testing in Clinical Specimens

  • KIM BYOUNG-GUK;JEONG HYE-SUNG;BAEK SUN-YOUNG;SHIN JIN-HO;KIM JAE-OK;MIN KYUNG-IL;RYU SEUNG-REL;MIN BOK-SOON;KIM DO-KEUN;JEONG YONG-SEOK;PARK SUE-NIE
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.595-602
    • /
    • 2005
  • A one-step real-time quantitative RT-PCR assay in combination with automated RNA extraction was evaluated for routine testing of HCV RNA in the laboratory. Specific primers and probes were developed to detect 302 bp on 5'-UTR of HCV RNA. The assay was able to quantitate a dynamic linear range of $10^7-10^1$ HCV RNA copies/reaction ($R^2=0.997$). The synthetic HCV RNA standard of $1.84{\pm}0.1\;(mean{\pm}SD)$ copies developed in this study corresponded to 1 international unit (IU) of WHO International Standard for HCV RNA (96/790 I). The detection limit of the assay was 3 RNA copies/reaction (81 IU/ml) in plasma samples. The assay was comparable to the Amplicor HCV Monitor (Monitor) assay with correlation coefficient r=0.985, but was more sensitive than the Monitor assay. The assay could be completed within 3 h from RNA extraction to detection and data analysis for up to 32 samples. It allowed rapid RNA extraction, detection, and quantitation of HCV RNA in plasma samples. The method provided sufficient sensitivity and reproducibility and proved to be fast and labor-saving, so that it was suitable for high throughput HCV RNA test.

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise-Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

  • Lee, Jaeick;Lee, Seunghwa;Kim, Byungjoo;Lee, Joonhee;Kwon, Oh-Seung;Cha, Eunju
    • Mass Spectrometry Letters
    • /
    • 제9권1호
    • /
    • pp.30-36
    • /
    • 2018
  • A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.

고속액체크로마토그래피를 이용한 사람 혈장중 메비놀린 산의 정량 (Quantitation of Mevinolinic Acid in Human Plasma by HPLC)

  • 오한석;박동영;서성훈;김영관;홍선표;최영욱;이경태
    • Journal of Pharmaceutical Investigation
    • /
    • 제30권4호
    • /
    • pp.279-282
    • /
    • 2000
  • Simple and precise high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of a HMG-CoA reductase inhibitor, $lovastatin^{TM}$ and its active metabolite (mevinolinic acid) in human plasma. The method involved solid phase extraction of mevinolinic acid and internal standard using Sep-Pak Cartridge. Samples were analyzed by reversed-phase HPLC using $Capcell-Pak\;C_{18}$ column with ultraviolet detection at 238 nm. The quantitation limit of mevinolinic acid was 2 ng/ml and the calibration curve was linear over the range of 2-50 ng/ml $(r^2>0.999)$ with human plasma. The analyses of quality control samples indicated that the normal values could be predicted with an accuracy >97%. The intra- and inter-day coefficients of variation for the analyses were <10%. The average recoveries were similar (79%) for mevinolinic acid and methylmevinolinic acid. The method described has been successfully applied to the quantification of mevinolinic acid in about 1,000 human plasma samples over six-month period.

  • PDF

Quantitation of Hepatitis C Viral RNA Using Direct CRT-PCR

  • Park, Young-Suk;Lee, Kyung-Ok;Oh, Moon-Ju;Chai, Young-Gyu
    • BMB Reports
    • /
    • 제30권3호
    • /
    • pp.234-236
    • /
    • 1997
  • Chronic hepatitis C virus (HCV) infection is associated with the rapid development of cirrhosis and hepatocellular carcinoma. It has been reported that the amount of HCV RNA may be correlated with the progression of hepatitis and may be a prognostic marker for treatment of HCV patients. The direct detection of HCV RNA by reverse transcription-polymerase chain reaction (RT-PCR) is widely used to determine the presence of circulating virions. The most relevant limit of this approach is the lack of quantitative information about the viral titer. In the present study, we developed the method for HCV quantitation using competitive reverse transcription (CRT)-PCR using the deleted HCV standard. The serially diluted standard was added in titrated amounts to the target HCV RNA. The mixture was then reverse transcribed and amplified in the same reaction tube. The methods were evaluated using over 110 HCV-PCR positive samples in Koreans. About 59% of the samples were judged to contain $10^{5}-10^{6}$ copies of HCV RNA in 1 ml of serum.

  • PDF

Development of Pretreatment Method for Analysis of Vitamin B12 in Cereal Infant Formula using Immunoaffinity Chromatography and High-Performance Liquid Chromatography

  • Park, Jung Min;Koh, Jong Ho;Kim, Jin Man
    • 한국축산식품학회지
    • /
    • 제41권2호
    • /
    • pp.335-342
    • /
    • 2021
  • Vitamin B12 deficiency may lead to serious health issues in both infants and adults. A simple analytical method involving sample pretreatment with enzyme, followed by cyanide addition under acidic conditions; separation on an immunoaffinity column; and high-performance liquid chromatography (HPLC) was developed for the rapid detection and quantitation of vitamin B12 in powdered milk. Detection limit and powdered milk recovery were determined by quantitative analysis. The limits of detection and quantitation were 2.71 and 8.21 ㎍/L, respectively. Relative standard deviations of the intra-day and inter-day precisions varied in the ranges of 0.98%-5.31% and 2.16%-3.90%, respectively. Recovery of the analysis varied in the range of 83.41%-106.57%, suggesting that the values were acceptable. Additionally, vitamin B12 content and recovery in SRM 1849a were 54.10 ㎍/kg and 112.24%, respectively. Our results suggested that the analytical method, including the sample pretreatment step, was valid. This analytical method can be implemented in many laboratory-scale experiments that seek to save time and labor. Therefore, this study shows that immunoaffinity-HPLC/ultraviolet is an acceptable technique for constructing a reliable database on vitamin B12 in powdered milk containing starch as well as protein and/or fat in high amounts.

한국인에서의 경구용 클로나제팜의 약물동력학적 특성 (Pharmacokinetic Characteristics of Oral Clonazepam in Korean)

  • 정지훈;유대식;박준홍;이석용;손의동
    • 약학회지
    • /
    • 제48권5호
    • /
    • pp.278-284
    • /
    • 2004
  • In order to determine the bioavailability of c1onazepam, an anxiolytic drug, a simple, rapid and sensitive HPLC analysis was developed in healthy Korean volunteers. The analysis system was validated in specificity, accuracy, precision and linearity. The analysis condition we established was 2.58 min and 5 ng/$m\ell$ in retention time and limit of quantitation of c1onazepam, respectively, using reverse-phase C18 column connected to UV detector. Quantitation was performed at 235 nm wave length with p-hydroxybenzoic acid ethyl ester as internal standard. The method involved a simple extraction. In order to study blood level profiles as a function of time, eight volunteers were enrolled and orally took 6 mg clonazepam once. The blood samples were collected from 0 to 120 h after the drug administration. Mean AUC and Cmax value were 1028.17$\pm$568.165 (ng/$m\ell$$.$hr) and 41.25$\pm$10.82 (ng/$m\ell$), respectively. And mean Tmax and T$_{1}$2/ value were 1.08$\pm$0.42 (hr) and 30.78$\pm$3.26 (hr). From the results we determine the pharmacokinetic characteristics of clonazepam in Korean people using a newly developed and useful HPLC method.

광어에서 Cephalexin의 잔류 소실에 관한 연구 (Residue Depletion of Cephalexin in the Flounder (Paralichthys olivaceus))

  • 임종환;장범수;박병권;윤효인
    • 대한수의학회지
    • /
    • 제43권3호
    • /
    • pp.435-438
    • /
    • 2003
  • The objective of this study was to investigate the residue depletion of cephaalexin in the flounder (Paralichthys olivaceus) after multiple oral administrations and to establish the appropriate withdrawal time for edible tissues. A highly sensitive and specific method for the determination of cephalexin in the serum of flounder by LC/MS was developed and validated. Mean recoveries from serum were 87.2% (ranged from 81.2% to 94.5%) for cepalexin. Recovery and precision met the criteria for the guideline of residual analysis of veterinary drugs by the National Veterinary Research and Quarantine Service (NVRQS) in Korea. The limit of detection and limit of quantitation of cephalexin were 10 ng/ml and 50 ng/ml, respectively. Residual levels of cephalexin in muscle samples were estimated with 95% tolerance limit and 95% confidence to fall below the MRL after a withdrawal time of 4 days and 5 days for the 40 and 160 mg/kg/day, respectively.