• Title/Summary/Keyword: limit index

Search Result 595, Processing Time 0.027 seconds

Index Properties and Undrained Shear Strength of the Pusan Clays by Fall Cone Test (부산점토의 Fall Cone Test에 의한 지수 및 강도특성)

  • ;;Pham Huy Giao
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.391-398
    • /
    • 2000
  • The index properties of cohesive soils play an important role to examine entire tendency of soil properties. Especially, the Atterberg limits have a good correlation with compression and shear strength of cohesive soils. However, these values strongly depend on their testing methods. In this study, for Pusan clays the Atterberg limits were peformed under different conditions; for example, four kinds of specimen preparation, two kinds of testing equipment, and four kinds of estimating method. And a laboratory vane test was peformed to compare the undrained shear strength with that of the fall cone test. As experimental results, the value of liquid limit performed for oven-dried sample, followed in ASTM D4318, underestimated by about 10% compared to those of another three methods, irrespective to the used equipments. But the value of plastic limit was not influenced by sample preparation methods and equipments. The liquid limits by one-point methods(Leroueil et al., 1996; Nagaraj et al., 1981) were agreed well with those of different methods. Finally, the undrained shear strength by laboratory vane test was relatively larger than that of fall cone test, and the relationship between both showed a bad trend.

  • PDF

GROUND TREATMENT CASE HISTORY OFR SOFT CLAY LAYER AND EVALUATION OF ITS IMPROVEMENT (연약지반처리와 개량효과 평가사례)

  • Lee, Yeong-Nam;Lee, Hyeong-Ju;Sim, Dong-Hyeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.10a
    • /
    • pp.113-120
    • /
    • 1992
  • The construction of container terminal at Brani, Singapore required the improvement of soft clay layer having the thickness of about 6.5m, average moisture content of 79.4%, liquid limit of 90.4%, plastic limit of 21.8%, field vane strength of 10 to 25 KPa, pre-consolidation pressure of 225 to 60 KPa and compression index of 0.4 to 1.0. For the improvement of this layer, Colbon drains of 1.3m spacing in triangular pattern were installed to the bottom of the layer and surcharge of more than 11.25m high sand fill was later applied to the treated area. The settlement and lateral displacement of the ground were measured and the speed of surcharge filling was controlled, based on these readings. The removal of surcharge was determinied using the estimated time for the 90% degree of consolidation under the design pressure of 180KPa. The field and laboratory test results show that the soft clay layer has been improved substantially in its strength and consolidation characteristics: increase in strength of about 50KPa and pre-consolidation pressure and decrease in void ratio and compression index.

  • PDF

Interaction of industrial effluents and bentonite: a comparative study of their physico-chemical and geotechnical characteristics

  • Murugaiyan, V.;Saravanane, R.;Sundararajan, T.
    • Geomechanics and Engineering
    • /
    • v.1 no.4
    • /
    • pp.291-306
    • /
    • 2009
  • One-dimensional soil-column studies were carried out to understand the interaction of three industrial effluents namely amino acid ('highly acidic'), surfactant ('highly organic') and pharmaceutical ('organic and toxic') on the physicochemical behavior, index properties and shear strength of bentonite due to artificial contamination extending to nearly 300 days. Changes in inorganic and organic pollutants present in the effluents due to the interaction of the above effluents and soil were assessed to understand the physico-chemical behaviour. Batch and continuous modes of operation, 8 hrs and 16 hrs Hydraulic Retention Time [HRT] and 25%, 50% concentrations of effluents, were the parameters considered. Amino acid, surfactant and pharmaceutical effluents have shown a high variation in pH (7 to 8) after artificial contamination on bentonite that is their original characteristics of the above effluents have been completely reversed. Further, it is found that the shear strength of bentonite has reduced by about 20%, and with respect to liquid limit and plastic limit shows an increasing trend with time within the period of contamination.

Reliability studies on RC beams exposed to fire based on IS456:2000 design methods

  • Balaji, Aneesha;Aathira, M.S.;Pillai, T.M. Madhavan;Nagarajan, Praveen
    • Structural Engineering and Mechanics
    • /
    • v.59 no.5
    • /
    • pp.853-866
    • /
    • 2016
  • This paper examines a methodology for computing the probability of structural failure of reinforced concrete beams subjected to fire. The significant load variables considered are dead load, sustained live load and fire temperature. Resistance is expressed in terms of moment capacity with random variables taken as yield strength of steel, concrete class (or grade of concrete), beam width and depth. The flexural capacity is determined based on the design equations recommended in Indian standard IS456:2000. Simplified method named $500^{\circ}C$ isotherm method detailed in Eurocode 2 is incorporated for fire design. A transient thermal analysis is conducted using finite element software ANSYS$^{(R)}$ Release15. Reliability is evaluated from the initial state to 4h of fire exposure based on the first order reliability method (FORM). A procedure is coded in MATLAB for finding the reliability index. This procedure is validated with available literature. The effect of various parameters like effective cover, yield strength of steel, grade of concrete, distribution of reinforcement bars and aggregate type on reliability indices are studied. Parameters like effective cover of concrete, yield strength of steel has a significant effect on reliability of beams. Different failure modes like limit state of flexure and limit state of shear are checked.

Multiple characteristic response damage analysis of large-span space structures based on equivalent damping ratio

  • Wei, Jun;Yang, Qingshun;Zhou, Lexiang;Chen, Fei
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.339-352
    • /
    • 2022
  • Due to the large volume and generally as a public building, the damage of large-span space structures under various non-conventional loads will cause greater economic losses, casualties, and social impacts, etc. Therefore, it is particularly important to evaluate the seismic performance of large-span space structures. This paper taked a multipurpose sports center as an example and considered its synergistic deformation based on the method of equivalent damping ratio. Furthermore, The ABAQUS software was used to analyze the time-history and energy response of the multipurpose sports center under the action of rare earthquakes, and proposed a quantitative damage index to assess the overall damage of the structure. Finally, the research results indicated that the maximum inter-story drift ratio of the multipurpose sports center under the action of rare earthquakes was less than its limit value. The frame beams presented different degrees of damage, but the key members were basically in an elastic state. The bearing capacity did not reach the limit value, which satisfied the intended seismic performance target. This study taked an actual case as an example and proposed a relevant damage evaluation system, which provided some reference for the analysis of the seismic performance of large-span space structures.

A Study on The Relationship Between Driver Expectancy and Variable Speed Limit Under the Adverse Weather Conditions By Using A Driving Simulator (악천후 시 운전자 기대심리와 가변 제한속도간 관계정립을 위한 가상주행 시뮬레이터 연구)

  • Kim, Yongseok;Lee, Sukki;Kim, Soullam
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.6
    • /
    • pp.138-149
    • /
    • 2016
  • The study reviewed the effects of the variable speed limit under adverse weather conditions by using a driving simulator. The study assumed that the display of the reduced speed limit without any change of the weather condition and the display of the same speed limit under the change of the weather conditions violate the expectancy of drivers, so it brings the negative effects on the safety. The study regards drivers conformance as the index of the degree of the compliance of driver expectancy, and utilizes the cumulative probability density within the certain range of the speed including displayed speed limit as the quantitative measure of effectiveness. The study reviewed this assumptions by using a driving simulator. As the results, the cases assumed to violate the expectancy of drivers showed the negative effects on the driving behaviour of driver relatively.

Hazard Assessment of Combustion Gases from Interior Materials (주요 건축 내장재의 연소가스 유해성 평가)

  • Seo, Hyun Jeong;Son, Dong Won
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.49-56
    • /
    • 2015
  • Toxic gases from five types of interior building materials were investigated according to Naval Engineering Standard (NES) 713. The materials were plywood, indoor wall coverings (wood wall plate members and pine wood), reinforced Styrofoam insulation, laminate flooring, and PVC. Specimens were measured using an NES 713 toxicity test apparatus to analyze the hazardous substances in combustion gas from the materials. We used the US Department of Defense standard (MIL-DTL, Military Standard) to calculate the toxicity index of the combustion gas. Emissions of $CO_2$ from all specimens did not exceed the NES 713 limit of 100,000 ppm. The amount of CO gas emissions from reinforced Styrofoam insulation was 6,098 ppm. 25 ppm and 49 ppm of formaldehyde were released from the reinforced Styrofoam insulation and PVC flooring, respectively. These values were less than the limit of 400 ppm. The highest emissions were from $NO_X$ emitted by plywood and were above the limit of 250 ppm. The toxicity index of the specimens were calculated as 5.19 for plywood, 4.13 for PVC flooring, 2.35 for reinforced Styrofoam insulation, 2.34 for laminate flooring, and 1.22 for indoor wall coverings (pine wood). Our research helps us to understand the properties of these five interior materials by analyzing the combustion gas and explaining the toxicity of constituents and the toxicity index. Also, it would be useful for giving fundamentals to guide the safe use of interior materials for applications.

The Effects of Decompression Therapy by Fixed Pelvic System on Low Back Pain During Pregnancy (골반고정장치에 의한 감압치료가 임산부 요통환자의 통증, 일상생활 제한 및 요추만곡에 미 치는 영향에 관한 연구)

  • Kim, Hee-Ra;Kim, Yoon-Shin;Kim, Seong-Ho;Kim, Myung-Joon
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Background and Purpose : This study serves the purpose to present the effective way on back pain therapy for women during their pregnancy by comparing and analyzing the effects influencing on pain index, limits on daily life, and diminution of lumbar curve, when having treated for 6 weeks, dividing into therapy group, applied by decompression therapy on spine without unnecessary effects on the pregnant women and their fetus and the existent general physiotherapy group, applied on diminution of their back pain. Subject & methods : We made impregnate women of 30(25${\sim}$34years), as the subject of this study, who understood, and agreed with, this study, among pregnant women who were diagnosed as back pain. Pain intensity, limit index on daily life, and lumbar curve test, prior to experiment was implemented as paired t-test, comparison of the difference of average by each group before and after experiment was analysed as independent t-test, and statistical examination level was set up as 0.05. Results : The difference of average of pain and limit on daily life between the group, SDTG(spinal decompression therapy group), and the group, GPTG(general physical therapy group), before and after experiment was diminished as much as 44.4% and 16.79% each after completed 6 weeks' experiment, limit on daily life in both groups showed as much as 37.2% and 21.5% each, in the end, they statistically showed conspicuous difference(p<.05). Comparison of lumbar curves between both groups, SDTG and GPTG, before and after experiment, were diminished from -23.13${\pm}$4.85 to -15.66${\pm}$3.71, and there was no remarkable difference(p<.05). Conclusion : As, in this study, decompression therapy is more effective than general physical therapy with pregnancy low back pain in pain, limitation of daily life, lumbar curve.

  • PDF

Analysis of Live Load Factor for Bridge Evaluation Through Reliability Based Load Factor Calibration (신뢰도기반 하중계수 캘리브레이션을 통한 교량 평가 활하중계수 분석)

  • Yoo, Min-Sun;Kim, Kyung-Hyun;Paik, In-Yeol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.212-221
    • /
    • 2022
  • In this paper, the evaluation procedure applying the limit state design method is studied to be consistent with the newly issued bridge design code in Korea. The live load factor for evaluation is proposed by calibrating for the target reliability index through reliability analysis. Using the actual bridge information collected for the representative bridge types in Korea, the load effects of the design live loads for the previous and current design codes are calculated and compared. The live load factor is calibrated through reliability analysis using the minimum required strength which equals to the load effect obtained for the example bridge. Bridge evaluation is performed by applying the live load factors for the evaluation level as well as design level. The load rating result is generally increased by applying the limit state design method compared to the previous design method and applying the proposed load factor for lowered target reliability index further increased the rating result.

Consolidation characteristics of slurry by Rowe Cell (Rowe Cell을 이용한 슬러리점토의 압밀특성)

  • 정규향;조진구;주재우;백원진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.875-883
    • /
    • 2003
  • Slurry clay has much higher water content than liquid limit of clay and even if small loads apply, it suffers a great settlement. Accordingly it is very difficult to perform a general consolidation test about slurry clay because of high water content. In this study consolidation tests have been performed successfully using Rowe Cell Tester about 1 remolding clay and 3 slurry clays with a water content of 100%, 133% and 150%. From the test results compression index characteristics, secondary compression index characteristics and consolidation coefficient characteristics have been investigated about slurry clay and remolding clay. Also two kinds of theory, by Terzaghi theory and by Mikasa theory, has been used to calculate consolidation coefficients. Compared to the calculation results, they had a similar value of consolidation coefficient. However if Mikasa theory is applied in the field design, the period which reach to the required consolidation degree will be much reduced compared to the period by Terzaghi theory because the time coefficient T$\_$v/ by Mikasa theory is far smaller than T$\_$v/ by Terzaghi theory.

  • PDF