• Title/Summary/Keyword: limb development

Search Result 185, Processing Time 0.033 seconds

Correlates of Lymphedema in Women with Breast Cancer: a Case Control Study in Shiraz, Southern Iran

  • Honarvar, Behnam;Sayar, Negin;Tahmasebi, Sedigheh;Zakeri, Zeinab;Talei, Asra;Rostami, Sara;Khademi, Sahar;Sarvestani, Amene Sabzi;Sekhavati, Eghbal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.81-85
    • /
    • 2016
  • Globally, the burden of breast cancer (BC) continues to increase. BC related lymphedema (BCRL) is currently non curable and as a life time risk it affects at least 25% of BC patients. Knowing more about BCRL and appropriate control of its modifiable risk factors can improve quality of life (QOL) of the affected patients. In this case control study to detect factors, 400 women with BCRL (as the case group) and 283 patients with BC without lymphedema (as the control group) that were referred to Shiraz University of Medical Sciences affiliated BC clinic center were assessed. The data were analyzed in SPSS. The mean age of the case group was $52.3{\pm}11.0years$ and of the control group was $50.1{\pm}10.9years$. In patients with BCRL, 203(50.7%) had left (Lt) side BC and in non- lymphedema group 151 (53.3%) had Lt side BC. Out of all BCRL patients, 204 (51%) had lymphedema in all parts of their affected upper extremities, 100 (25%) had swelling in the arm and forearm and 23 (5.7%) had edema in both the upper extremity and trunk. Edema, heaviness, concern about changing body image, pain and paresthesia were the most common signs/symptoms among patients with BCRL. In BCRL patients, the difference of circumference between the affected upper limb and non-affected limb was $4.4{\pm}2.5cm$ and the difference in volume displacement was $528.7{\pm}374.4milliliters$. Multiple variable analysis showed that moderate to severe activity (OR; odds ratio =14, 95% CI :2.6-73.3), invasiveness of BC (OR =13.7, 95% CI :7.3-25.6), modified radical mastectomy (OR=4.3, 95% CI :2.3-7.9), BMI =>25 (OR=4.2, 95% CI :2-8.7), radiotherapy (OR=3.9, 95% CI :1.8-8.2), past history of limb damage (OR=1.7, 95% CI :0.9-3.1) and the number of excised lymph nodes (OR=1.06, 95% CI :1.02-1.09) were the significant predictors of lymphedema in women with BC. Modifiable risk factors of BCRL such as non-guided moderate to severe physical activity, high BMI and trauma to the limb should be controlled as early as possible in BC patients to prevent development of BCRL and improve QOL of these patients.

Development and Evaluation of Rollator for Elderly Farmers

  • Lee, Kyung Suk;Kim, Kyung Ran;Kim, Hyo Cher;Chae, Hye Seon;Kim, Sung Woo;Seo, Min Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.487-497
    • /
    • 2014
  • Objective: This study aims to develop and evaluate a multi-purpose rollator, which may be used as a seat, as a traditional walker, or as a storage basket for elderly farmers. Background: The rollators on the market are not user-friendly designed and seen inconvenient for elderly farmers to use, although they are sold at considerably high price. Since they lack enough space to load stuffs and are not durable or stable enough, they do not seem to be suitable for elderly farmers to use in rural areas. Method: Two types of methods were used in this study. First, the survey consisted of 19 questions was conducted among elderly farmers in rural areas, after using the developed rollator, to evaluate the usability of the rollator developed in this study. Second, EMG experiment was conducted to compare the existing rollator and developed rollator quantitatively. Through this experiment, we tried to verify the differences of muscle responses, when using the traditional and the developed ones, which have their own brake system, in the ramp. Results: The developed rollator was highly evaluated in most of the questions in the usability survey, except for the 'Weight' category in which the opinions were divided into three different types (Worse: 31%, Similar: 30%, Better: 36%). The result of EMG experiment showed that the existing rollator (7.4%MVC) demands more muscle strength than the developed rollator (5.5%MVC) does. By statistically analyzing the results of upper limb and lower limb respectively, we found out that all the muscles except deltoid in upper limb showed statistically significant differences in muscle activity when using the existing and the developed rollator. However, there was no statistical difference in lower limb muscles. Conclusion: The developed rollator in this study has maximized the functionality of the brake system, the storage and the chair, which were pointed out as the weaknesses of existing rollators. Furthermore, the developed rollator is designed to be more user-friendly, safe, durable, and effective for elderly farmers to use in rural areas, where roads are rough and bumpy. Application: We expect that the emergency brake system developed in this study would be utilized for other convenience equipment, such as strollers and carts, and that it would be able to develop and produce more secure and reliable equipment in the future.

The effect of caspase-3 inhibition on interdigital tissue regression in explant cultures of developing mouse limbs

  • Kudelova, Judita;Tucker, Abigail S.;Dubska, Lenka;Chlastakova, Ivana;Doubek, Jaroslav;Matalova, Eva
    • Animal cells and systems
    • /
    • v.16 no.4
    • /
    • pp.295-301
    • /
    • 2012
  • Interdigital tissue regression is one of the most well-known examples of embryonic programmed cell death, providing the mechanism behind separation of developing digits. Caspases have been shown to play a key part in this process, with activated caspase-3 localized between the developing digits. In caspase-3 knock-out adult mice, however, the digits are completely separated with no webbing. In other mutants with defects in the apoptotic machinery, such as Apaf1 deficient mice, interdigital tissue regression is initially inhibited but the webbing eventually disappears as alternative/additional cell death mechanisms step in. In order to investigate whether a similar temporal effect occurs after loss of caspase-3, we have used an in vitro approach to inhibit caspase-3 at specific times during digit separation. Previous limb explant culture approaches have encountered problems with proper limb development in culture, and thus a modified technique was used. The new approach enables detailed observation of the effects of caspase-3 inhibition on interdigital regression. Using these methods, we show that caspase-3 inhibition caused a delay in the loss of interdigital tissue compared with control explants, similar to that observed in Apaf1 mutant mice. Along with immunohistochemistry, active caspase-3 positive cells of the interdigital vs. digital regions were measured by flow cytometry. Notably, activated caspase-3 in vivo was found not only in the interdigital mesenchyme but also in the TUNEL negative digit region, supporting a role for caspase-3 in nonapoptotic events.

Development of Multi-rotational Prosthetic Foot for Lower Limb Amputee (하지 절단자를 위한 다축 회전이 가능한 인공발의 개발)

  • Shin, Hyunjun;Park, Jin-Kuk;Cho, Hyeon-Seok;Ryu, Jei-Cheong;Kim, Shin-Ki
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.305-313
    • /
    • 2016
  • Movements of the lower limb are important for normal walking and smooth oscillation of the center of gravity. The ankle rotations such as dorsi-flexion, plantar-flexion, inversion and eversion allows the foot to accommodate to ground during level ground walking. Current below knee (B/K) prostheses are used for replacing amputated ankle, and make it possible for amputees to walk again. However, most of amputees with B/K prostheses often experience a loss of terrain adaptability as well as stability because of limited ankle rotation. This study is focused on the development of multi-rotational prosthetic foot for lower limb amputee. Our prosthesis is possible for amputees to easily walk in level ground by rotating ankle joint in sagittal plane and adapt to the abnormal terrain with ankle rotation in coronal plane. The resistance of ankle joint in the direction of dorsi/plantar-flexion can be manually regulated by hydraulic damper with controllable nozzle. Furthermore, double layered rubber induce the prosthesis adapt to irregular ground by tilting itself in direction of eversion and inversion. The experimental results highlights the potential that our prosthesis induce a normal gait for below knee amputee.

A Study on Product Development to Promote the Effects of Exercise on Children and to Induce Their Interest in Exercise: A Survey on the Development of Cognitive and Motor Functions in Children

  • Cho, Hyun-Seung;Yang, Jin-Hee;Jung, Chan-Woong;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.41-48
    • /
    • 2017
  • This study was conducted to develop wearable products with visual and auditory feedback aimed at promoting exercise interest in children. Here we determined the theoretical characteristics of cognitive and motor function development during childhood, empirical characteristics of children's motor functions, and factors that encourage exercise using natural observation and in-depth interview research methods. The questionnaire assessed children's motor ability, intensively trained body parts in sports programs, types of training or classes that improve the motor ability of each muscle group, significantly considered aspects of children's sports programs, and factors that promote children's interest in exercise. Our results suggest that the development of sport programs comprising varied exercise options that enhance body and limb movements are needed for balanced growth. Furthermore, it is very important to provide motivation for regular exercise and appropriate feedback, such as praise and encouragement, to maintain interest in exercise. This study identifies the standards for developing products that peak children's interest in exercise and the basis for a physically and mentally healthy society.

Development of Rehabilitation Medicine Device for Compound Joint Motion (복합관절 운동용 재활의료기기)

  • 정성훈;유범상;김남균;박상민;송문상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.704-708
    • /
    • 2004
  • The RMD(Rehabilitation Medicine Device) with CJM(Compound Joint Motion) is the lower limb unit muscular strengthening promotion rehabilitation medicine device for patients of joint orthopedic operation or the deficient elder of ability to walk, the handicapped. Since the products for the rehabilitation medicine device have limited to the simplicity linear motion, those do not give efficient the lower unit muscular strengthening effects. This device which was under the development gives to exercise of hip joint and knee joint with user's selection at once, get out of the simplicity linear motion. Also it will be contributed to a field of rehabilitation medicine and a mobility aid technology of the deficient elders of ability to walk, the handicapped.

  • PDF

The Review of Proprioceptive Activities in Sensory Integration Intervention (감각통합치료에서 고유수용성 감각 활동에 관한 고찰)

  • Kim, Jin-Mi;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.5 no.1
    • /
    • pp.51-63
    • /
    • 2007
  • The purpose of this study is to provide definition of proprioception, foundations and roles of neuroanatomy, and systemical review of proprioceptive activities in sensory integration intervention. Proprioception exists in muscle, ligaments, joints and skin and it plays important role in controling body movements and interacting with environment during child development. Proprioception interacting with tactile and vestibular systems contributes to the change of muscle tone, postural control, refinements of planning and praxis. Children who are deficit in proprioceptive processing would seek hypo-responsive proprioceptive input or avoid hyperactive one. Outcome of poor proprioceptive input would cause the problems of praxis and postural control. Because proprioception provides information about the position and movement of body and limb it is important for development of body scheme and motor planning. It also influences the arousal and emotional tone. Sensory integration intervention which provides rich proprioceptive activities will improve the level of arousal and enhance motor planning.

  • PDF

Cyclopamine, an Antagonist of Hedgehog (Hh) Signaling Pathway, Reduces the Hatching Rate of Parthenogenetic Murine Embryos

  • Park, Jaehyun;Moon, Jeonghyeon;Min, Sol;Chae, Stephan;Roh, Sangho
    • Journal of Embryo Transfer
    • /
    • v.33 no.4
    • /
    • pp.237-243
    • /
    • 2018
  • Hedgehog (Hh) pathway plays a key role in development from invertebrate to vertebrate. It is known to be involved in cell differentiation, polarity, proliferation, including the development of vertebrate limb and the establishment of flies' body plan. To investigate how the regulation of Hh pathway affects the development of parthenogenetic murine embryos, the parthenogenetically activated murine embryos were treated with either cyclopamine (Cyc), an antagonist of Hh pathway, or purmorphamine, an agonist of Hh pathway. While Cyc did not affect the blastocyst formation and its total cell number, the chemical reduced the hatching rate of embryos and the expression levels of Fn1 mRNA. The results of the present study show the possibility that Cyc may affect the development of embryos at blastocyst stage by blocking Hh pathway and this may cause detrimental effect to the embryos at peri-, and post-implantation stages.

Digital Polysomnography:The Present and Future (디지털 수면다원기록법:현재와 미래)

  • Shin, Hong-Beom;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.2
    • /
    • pp.73-79
    • /
    • 2004
  • Digital polysomnography was developed to overcome the limitations of Rechtschaffen and Kales rule and to compensate the shortcomings of paper polysomnography. It enables easy access to and secure preservation of sleep records, and provides various displays of sleep data to enhance efficiency of visual scoring of sleep records. Rechtschaffen and Kales rule had been criticized for its ambiguity and lack of considerations in spatial information of EEG. As sleep records are acquired and processed in digital mode, they can be analyzed at microscopic and macroscopic levels. Digital analysis of sleep records provides the basis for development of new sleep measures. Sleep staging in digital polysomnography is based on the various analyses of EEG. Sleep apnea, hypopnea and periodic limb movement are detected automatically by digital analysis of respiratory signals and leg EMG. Digital polysomnography plays a complementary role to visual scoring and compensates the limitations of paper polysomnography. Digital polysomnography, including acquisition, processing and analysis of sleep records in digital mode, can be a great help in the development of sleep medicine, enabling the development of new sleep measures and the exchange of sleep records between sleep laboratories.

  • PDF

Development and Evaluation of the Auditory Feedback Gait Training System Induced Symmetrical Weight-Bearing in Hemiplegic Patients (편마비 환자의 대칭적 체중부하 유도를 위한 청각적 피드백 보행훈련 시스템 개발 및 평가)

  • Kwon, Y.C.;Lee, H.J.;Tae, K.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.23-30
    • /
    • 2012
  • In this study, we developed a wireless rehabilitation auditory feedback gait training system for symmetrical weight-bearing in patient with CVA. The device consists of an instantaneous shoe equipped with two load-cell sensors. Auditory feedback can be applied according to the weight-bearing. For gait patterns analysis, cadence, walking velocity, stance/swing phase ratio and gait cycle were examined. The clinical test with six healthy volunteers and two hemiplegic patients was performed applying the auditory feedback system. Both normal subjects and hemiplegic patients were increased strength on weight-bearing in affected limb, walking velocity, and cadence after biofeedback device. Also, the stance time with weight-bearing was increased while the swing time was decreased in gait phase. It can be expected that by using the feedback system, the patient with lower limb disorder will be able to reach a better quality of weight-bearing during gait.

  • PDF