• Title/Summary/Keyword: lighting condition

Search Result 335, Processing Time 0.033 seconds

CONTROL ON PLANT FACTORY IN OPTICAL RADIANT CONDITION ACCORDING TO THE MARKET ECONOMICS

  • Akamine, T.;Murase, H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.586-592
    • /
    • 2000
  • There is currently no satisfactory way to optimize supplemental lighting in a greenhouse-type plant factory especially concerning plant production. In a commercial plant factory, we got outside radiation data, inside radiation data and lamp running data. They have a correlation, but have much disorder. By using regression, tendency between the outside and the inside including supplemental lighting was found. We could estimate the average transmittance of this plant factory. From this estimation, we could admit the amount of inside radiation was supplied as much supplied compared to natural radiation. Then we are trying to investigate of the production amount and the supplemental lighting. Plant factory is environmentally controlled, the temperature and humidity are not actually controlled stable. We propose a design of neural network model could be useful to estimate the profit resulting from the operation of supplemental lighting.

  • PDF

a Survey on the Actual Condition of Lighting Apparatus (일반용 및 산업용 조명기구 보급실태조사)

  • 곽희로;이진우;김문덕;강원구
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.3
    • /
    • pp.67-72
    • /
    • 1995
  • In this paper, we investigate the numbers and electrical capacities of general and industrial Korean lighting apparatus. The results show that the number of lighting apparatus are 68,211,000 in general and 53,836,000 in industrial building and the capacities of lighting apparatus are 3,261,609 kW in general and 4,278,683 kW in industrial building. The ratio of Lighting apparatus is that fluorescent lamps are 56.9%, high intensity discharge lamps are 29.7%, and incandescent lamps are 12.1%.

  • PDF

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

A study on the Assessment of Standard Wages for Constructing Luminaries for Landscope Lighting (경관조명기구의 설치에 대한 기준노임 산정에 관한 연구)

  • Yoo, Dong-Gil;Lee, Bok-Hee;Lee, Sok-Yeon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.169-172
    • /
    • 2008
  • Recently, landscape lighting is more and more installing in many places such as park, cultural heritages, large-scale structures, bridges, apartment, and so on. However, there is no the government-set official estimation for standard wages constructing luminaries for landscape lighting. The cost of construction is estimated based on the standard wages of related-similar installations such as internal lighting fixtures or the designer's subjective decision. Sometimes, it is overestimated or underestimated. In this paper, the fundamental process for estimating the standard wages constructing luminaries for landscape lighting is studied. The estimation method of standard wages constructing lighting fixtures was examined on the basis of the type and capacities of luminaries, installation places, type and shapes of installation auxiliary materials, worker's skill, and etc. As a result, some results obtained in this work were significantly, different with the standard wages for internal electric wiring published by Korea Electric Association. In the future, to improve the accuracy of the estimation of the standard wages for constructing luminaries for landscope lighting, detailed factors related to the installation condition and dimensions and types of luminaries should be considered.

  • PDF

Growth Responses and Introduction Plan of Interior Landscape Plants under Light Intensity of Fluorescent Light and Sunlight (형광등과 자연광의 광도에 따른 실내조경식물의 생육반응과 도입 방안)

  • Choi Kyoung-Ok;Lee Sang-Woo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.4 s.111
    • /
    • pp.119-128
    • /
    • 2005
  • This study was carried out to obtain fundamental information of growth response of interior landscape plants under a fluorescent lighting, a sunlight at indoor. Ficus elastica Roxb. vu. decora Hort, Spathiphyllum 'Clevelandii', Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' and Cordyline terminalis Kunth var. red edge Hort were examined under 100lux, 500lux, 1,000lux and 2,000lux light intensity consisted of fluorescent lighting and sunlight at indoor condition. Result of experiments are as follows; 1. A Ficus elastica Roxb. var. decora Hort plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting in cases of all conditions. 2. A Spathiphyllum 'Clevelandii' showed the best effective adaptations under law intensity among experimental plants. A Spathiphyllum 'Clevelandii', plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 1,000lux light intensity of fluorescent lighting in cases of all conditions. 3. It need the best high establishment of fluorescent lighting among experimental plants for good plant growth. A Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status was better showed under high light intensity in case of same light source. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting. 4. A Cordyline terminalis Kunth var. red edge Hort plant growth status was better showed under fluorescent lighting than sunlight. but, A plant growth status was better showed under $500lux\sim1,000lux$ than 2,000lux in cases of all intensity of fluorescent lighting. while, A plant growth status was better showed under $1,000lux\sim2,000lux$ in cases of all intensity of sunlight.

Elements and Actual Condition of Apartment Unit Remodeling - By In-depth Interviews on Residents and Specialists of Interior Design Companies - (아파트 단위주거의 리모델링 요소와 현황 - 인테리어디자인업체 실무자와 거주자 심층면접을 통하여 -)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Jeong, Youn-Hong
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.57-67
    • /
    • 2007
  • The purpose of this study was to grasp major elements and actual condition of apartment unit remodeling by in-depth interviews on residents and specialists. The interviews had been conducted to interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment unit. In-depth interview is a kind of qualitative method in which attention to reply of responses with open-access between interviewer and respondents. According to the results, remodeling elements were generally changing of lighting fixtures and finishing materials in the all spaces, integration of balcony into children's room, installation of furniture in kitchen and entrance, changing storage furnitures and equipments in bathroom. Artificial lighting method were selected generally whole lighting. Finishing materials were used ordinary (non environmentally-friendly) wallpaper and adhesion and tempered floor. There were unsatisfied factors after remodeling, these were dissatisfaction of design, construction defects, and stink of reflecting 'sick house'. Also they responded that they should be considering to use environmentally-friendly material at next remodeling.

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

A Study on Aspheric Optics European LED Streetlights Type for the Prevention of Light Pollution (빛 공해 방지를 위한 유럽형 LED 가로등용 비구면 광학계에 관한 연구)

  • Lee, Shi-Woo;Lee, Chang-Soo;Hyun, Dong-Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.429-436
    • /
    • 2013
  • In this study, we researched a pendant-type aspherical optical system, which could be applied to street lighting and security lighting in Europe. The goal of this research was eco-friendly artificial lighting that could be used for the one-to-one replacement of ordinary lighting. LED lighting was miniaturized by using one COB LED Module and one aspherical optical system, which could control the luminosity of the LED. Through the aspherical optical system, the light distribution angle could be controlled in a range of $140^{\circ}$ for the X-axis and $40^{\circ}$ for the Y-axis. This means that this optical system is appropriate for catenary-type lighting, which is widely used in Europe on both narrow and broad roads. The performance was determined using a lighting simulation program. This lighting system simulation showed that road rates M4 and M5 could be satisfied, with the condition of a 13-m height and 50-m distance (U0 and TI). The simulation program estimated that light pollution, which disturbs sleep, could beeliminated in the European streetlight case. Determining methods for the light distribution control, performance, and optimal lighting setup conditions is very important to prevent light pollution. Moreover, the initial step of developing the lighting system design and post management will require an effort with much analysis.

A Study on the Night Lighting Environment by Outdoor Space Types of an Apartment Complex (공동주택단지 외부공간 유형별 야간 빛 환경에 대한 연구)

  • Han, Jeong-Won;Ahn, Jil-Hye
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.3
    • /
    • pp.164-172
    • /
    • 2014
  • The purpose of this study is to identify current condition of night lighting plan for the outdoor space in an apartment complex and to examine how residents perceive that environment. For this purpose, considerations and standards for safe and agreeable night lighting environment were examined through literature study. And a field study to determine the current state of the night lighting environment was conducted, and finally a survey was executed to find out residents' satisfaction, requirements and consciousness on that lighting environment of apartment complex. Findings of this study can be summarized as follows. Firstly, most standards for night lighting environment focus on the urban environment as a whole, so they have very few clear standards exclusive for the outdoor space of the apartment complex. Secondly, most of outdoor spaces surveyed in this study have met the basic illumination standard, but some spaces had parts where lights were off or out of order forming dark zones, and in some parts lights were screened by trees causing shades, poor safety and a narrowed sight. Thirdly, residents had interest in the night lighting environment of the outdoor space, but they were not fully satisfied with that environment. Fourthly, residents were negative about such factors of the environment as safety, convenience, recognition and aesthetics. These factors should be reflected in planning and improving the night lighting. It is expected that this study provides basic information necessary to plan safer and more agreeable night lighting, and to satisfy the residents' need for liveable apartment complex.

The Growth Effects on Interior Landscape Plants by Optical Fiber Lighting System (광섬유 조명체계가 실내조경식물의 생육에 미치는 효과)

  • 최경옥;방광자
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.6
    • /
    • pp.92-100
    • /
    • 2002
  • This study was carried out to obtain fundamental information on the growth response of interior landscape plants under fluorescent light, sunlight and optical fiber lighting indoors. Saintpaulia ‘Delaware’, ‘Kalanchoe blossfeldiana, Anthurium scherzerianum and Ardisia crenata were examined using light intensity of 5001ux and 1,0001ux of fluorescent light, sunlight and optical fiber lighting in an interior environment. Results of experiments are as follows; 1) Plant growth status showed the best results under optical fiber lighting compared with fluorescent light or sunlight. 2) Plant growth status was better under 1,0001ux light intensity than 5001ux light intensity and in cases of the same light intensity, the highest growth increase was under optical fiber lighting. while it was showed relatively different according to the different plant species between a fluorescent light and sunlight. 3) The deep pinkish red color of Saintpaulia ‘Delaware’flower was obtained first under an optical fiber lighting and a fluorescent light, a sun light in that order. 4) Regarding interred activity, photosynthetic rate and transpiration rate, intercellular CO, water absorption rate showed a similar tendency generally in spite of a little difference. Namely, transpiration rate and intercellular CO, $CO_2$ a absorption rate increased according to increase of photosynthetic rate. 5) Photosynthetic rate of test plants except Anthurium scherzerianum increased according to increase of light intensity and increased highest under optical fiber lighting in the same light intensity condition. Increases differed under fluorescent light and sun light. That of Saineaulia ‘Delaware’and Anthurium scherzerianum increased in the order of optical fiber, fluorescent light and sun light, but that of Kalanchoe blossfeldiana and Ardisia pusilla increased in the order of optical fiber lighting, sun light and fluorescent light. Summing up these results, In visual value or internal health status of all experimental plants we obtained the highest result under an optical fiber lighting. Finally, we need to introduce an optical fiber lighting in interior landscape space as main light source.