• 제목/요약/키워드: lighting Energy

검색결과 677건 처리시간 0.021초

동적열해석프로그램을 이용한 대형할인매장의 에너지 소비 특성 분석 (The Energy Performance Analysis of Large Scale Store Using Dynamic Thermal Analysis Simulation Program)

  • 김병수;홍원표
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.44-49
    • /
    • 2010
  • The purpose of this study is to analyze the situation of energy consumption and its characteristics in large scale store. The related survey is carried out in large scale store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and others. The area of large scale discount store is about $65000m^2$, located in Daejeon. For Annual Energy Analysis of building, We surveyed used energy for 1 year and simulated using a building energy simulation(TRNSYS 16). The results of this study are as follows. 1)The amount of annual total energy consumption are 18615.244MWh/yr(286.4KWh/$m^2yr$), The rate of heating, cooling and base energy(for hot water, lighting, ventilation, equipments, cooking and others) is 3054MWh/yr(47kWh/$m^2yr$), 5660.09MWh/yr(87.08kWh/$m^2yr$), 9900.47MWh/yr(152.31KWh/$m^2yr$) respectively. The total used energy is higher than others building in Korea. Especially, The energy consumption of large scale store is very depends on operating period and pattern such as space temperature, occupancy, lighting system, equipments operating schedule and etc.

Ergonomics Planning에 의한 조명경향 분석 (A Tendency of the Lighting System by Ergonomics Planning)

  • 김희준;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2423-2425
    • /
    • 1999
  • During the last years demands for higher visual comfort, flexibility of the lighting system in new type of office structures, especially intelligent building, and compatibility with work at VDU place increased. At the same time better lighting conditions should be realized by energy-effective system leading to less consumption of energy. In the intelligent building need the now type of lighting control system, also it should be included for a human-sensibility. It is shown that when designing lighting for intelligent building, greater importances should be attached to the creation of a well-balanced luminance distribution in the field and research for the people by the Ergonomics Planning.

  • PDF

염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로 (A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space)

  • 이응직
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.

도로조명 방식이 운전자 시지각에 미치는 영향 (Effectiveness of Road Lighting on Driver' Vision)

  • 정준화;이석기;김원식;이미애
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.125-131
    • /
    • 2012
  • PURPOSES : Road lighting facilities increase the visibility of road at night in order to improve traffic driver safety and comfort. Generally speaking, current pole lighting has a tendency to create problems of glare and flicker. The phenomenon of glare gives discomfort due to increase of scattered light, when high luminance is in driver's field of view. The phenomenon of flicker occurs due to the driver passing through discontinuous pockets of pole lighting areas. These phenomenon increase eye strain and decrease driver safety. METHODS : Low height line lighting that distributes light lower than driver's eye level has been developed and evaluated to reduce the problems linked to current pole lighting. A test was undertaken with 4 conditions(turn on the general pole lighting, turn off alternate pole lighting, turn on the line lighting and line lighting with 50% dimming). A driver written survey was conducted in order to gain driver feedback. RESULTS : Pupil size and brow frequency compared with degree in pole lighting are reduced. CONCLUSIONS : Low height line lighting environment makes drivers more comfortable than pole lighting environment and is positive lighting method in the energy saving and landscape aspect.

주광이용 조광제어시스템의 적용성 향상을 위한 조명 에너지 절감량 예측 프로세스 개발 및 적용사례 (The Process and Example on the Prediction of Lighting Energy Savings for Daylight Responsive Dimming Systems Application)

  • 홍성관;박병철;최안섭;이정호
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.10-19
    • /
    • 2008
  • 광센서 조광제어시스템은 유용한 주광의 실내유입을 통하여 인공조명의 에너지를 절감하는 시스템이나, 쉐이팅시스템에 의한 주광유입의 차단으로 인하여 그 적용성은 미비하다. 따라서 광센서 조광제어시스템의 적용성 및 에너지 절감량 향상을 위해서는 자동롤러쉐이딩 시스템과의 통합은 필수적이다. 본 연구는 두 시스템을 통합한 주광이용 조광제어시스템의 적용성 향상을 위하여 시스템 적용 시 에너지 절감량을 예측할 수 있는 프로세스를 개발하고 이를 사례에 적용하였다. 개발된 프로세스는 주광이용 조광제어시스템의 초기투자비용 환수 및 시스템 적용을 위한 타당성 분석의 자료로 이용될 것이다.

인체감지를 통한 에너지절약 시스템 개발 (Energy Saving System Based on the Human Sensing Technique)

  • 이종필;지평식;신관우;임재윤
    • 전기학회논문지P
    • /
    • 제53권4호
    • /
    • pp.205-209
    • /
    • 2004
  • This research is investigated an energy saving system based on human detecting technique. It saves a lot of energy by automatic switching method of lighting, appliance, and so on. Existence of people on space is detected by infrared ray sensor. If there is not anybody during definite time, then main controller of system sends "power off" signal to lighting switches, and outlets. When people are detected again, turn on lighting switches and outlets. Result of this research is adaptable for classrooms and offices, and great effect of energy saving is expected.

주광을 활용한 LED조명시스템의 컨트롤에 관한 실험적 연구 (An Experimental Study on Control Strategy of LED System Using Daylight)

  • 윤경;윤갑천;김강수
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.33-39
    • /
    • 2010
  • Visual Environment and productivity are correlated. So we need to create a comfortable visual environment and maintain proper workplane illumination level. We can obtain lighting energy savings and comfortable visual environment using daylight and LED lights. In this study, we characterized the indoor illuminance level according to the sky condition and proposed dimming control strategy of LED lights. Energy savings in On/Off control mode are 40% at clear sky and 28% at intermediate sky. In dimming control mode, energy savings are 77.2% at clear sky and 64.1% at intermediate sky. Then we obtain the appropriate dimming control strategy of LED lights based on data. Dimming rates are 0-14.2-80(min-avg-max, %) for LED 1, 0-19.9-60% for LED 2 and 30-61.4-90% for LED 3. Lighting energy savings are 68.2% for LED dimming system applied this control method.

천창루버에 의한 내부공간 바닥면 조도변화와 설치방식에 관한 연구 (A study of Illumination on Floor Surface by Flat Form Louver of Top Lighting System)

  • 김미희;태원진
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.132-138
    • /
    • 2011
  • Inducing the natural lighting into building has been commonly applied to the spaces where artistic objects are displayed to create better visual environment for the appreciation. The direct natural lighting, especially through top lighting system may, however, bring forth discoloing of highly light-sensitive materials such as paintings or demanding additional cooling load. In addition, it causes to create glare against appreciators or to yield in visual distraction due to the extreme contrast on the inner surfaces of the spaces. Shading device such as louver is capable of preventing such voidable cases with careful manipulation. This study aims to provide basic design guide-line when the flat-form louver has to be applied to top lighting system. Interaction between the daylight and louver was simulated by Reluxpro program with variation of the attachment location, the angle of the lover, surface reflectivity, to obtain the illumination of the floor surface. This study yields the louver just under the top lighting window with 90 degree angle gives the most desirable way of employment when the uniform illumination on the floor surface is required.

밝기 제어가 가능한 IoT기반 LVDC LED조명 시스템 (Brightness Controllable LVDC LED Lightings Based on IoT)

  • 이연석;박건필;최상의
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.158-164
    • /
    • 2016
  • That's the reason why LED lighting has to employ AC power inlet. However, LED is a kind of diode, semiconductor, it's driven by DC power. With whis reason all of LED lighting should have AC/DC converter in its systems. This converter causes energy loss, it's the target for lesson the energy loss. To reduce this energy loss, DC power distribution structure can be used. LED lighting system using LVDC is a kind of DC power distribution structure, but LVDC has severe voltage drop which makes non-uniform brightness in lighting system. In this paper, we suggest a novel structure for the uniform brightness in LVDC LED lighting system using IoT based network system. The constructed test-bed system of suggested structure shows this structure can con control the brightness with uniformity.

LED 조명 방열 환경에서 진동형 히트파이프의 작동 특성 (Operational Characteristics of Pulsating Heat Pipes for the Application to the Heat Dissipation of LED Lighting)

  • 방광현;김형탁;박해균
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.830-836
    • /
    • 2012
  • An efficient cooling system is essential for the electronic packaging such as a high-luminance LED lighting. A special heat transport technology, Pulsating Heat Pipe (PHP), can be applied to the cooling of LED lighting. In this paper, the operational characteristics of the PHP in the imposed thermal boundary conditions of LED lighting were experimentally investigated. The experimental PHP was made of copper tubes of internal diameter of 2.1 mm. The working fluids of ethanol, FC-72, water, acetone and R-123 were chosen for comparison. The results showed that an optimum range of charging ratio exists for high cooling performance; 50% for most of the fluids. Among the five working fluids, water showed the highest heat transfer rate of 260 W. Two distinguished characteristics of pulsating direction were identified. It is also identified that high vapor pressure gradient is one of key parameters for better heat transfer performance.